An international multicenter cohort study on implantable cardioverter-defibrillators for the treatment of symptomatic children with catecholaminergic polymorphic ventricular tachycardia
Heart Rhythm · 2024
DOI: 10.1016/j.hrthm.2024.04.006 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Heart Rhythm, 2024. Verfasst von Avani Lamba und 47 weiteren Autor:innen. Beteiligte Einrichtung: BC Children's Hospital, Division of Cardiology, Department of Pediatrics, The University of British Columbia, Vancouver, British Columbia, Canada. Hauptthemen laut MEDLINE: Defibrillators, Implantable, Tachycardia, Ventricular, Death, Sudden, Cardiac. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 26 Literaturangaben.
Themen: Kinderkrankenpflege
Abstract (Originalsprache)
BACKGROUND: Catecholaminergic polymorphic ventricular tachycardia (CPVT) may cause sudden cardiac death (SCD) despite medical therapy. Therefore, implantable cardioverter-defibrillators (ICDs) are commonly advised. However, there is limited data on the outcomes of ICD use in children. OBJECTIVE: The purpose of this study was to compare the risk of arrhythmic events in pediatric patients with CPVT with and without an ICD. METHODS: We compared the risk of SCD in patients with RYR2 (ryanodine receptor 2) variants and phenotype-positive symptomatic CPVT patients with and without an ICD who were younger than 19 years and had no history of sudden cardiac arrest at phenotype diagnosis. The primary outcome was SCD; secondary outcomes were composite end points of SCD, sudden cardiac arrest, or appropriate ICD shocks with or without arrhythmic syncope. RESULTS: The study included 235 patients, 73 with an ICD (31.1%) and 162 without an ICD (68.9%). Over a median follow-up of 8.0 years (interquartile range 4.3-13.4 years), SCD occurred in 7 patients (3.0%), of whom 4 (57.1%) were noncompliant with medications and none had an ICD. Patients with ICD had a higher risk of both secondary composite outcomes (without syncope: hazard ratio 5.85; 95% confidence interval 3.40-10.09; P < .0001; with syncope: hazard ratio 2.55; 95% confidence interval 1.50-4.34; P = .0005). Thirty-one patients with ICD (42.5%) experienced appropriate shocks, 18 (24.7%) inappropriate shocks, and 21 (28.8%) device-related complications. CONCLUSION: SCD events occurred only in patients without an ICD and mostly in those not on optimal medical therapy. Patients with an ICD had a high risk of appropriate and inappropriate shocks, which may be reduced with appropriate device programming. Severe ICD complications were common, and risks vs benefits of ICDs need to be considered.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- BC Children's Hospital, Division of Cardiology, Department of Pediatrics, The University of British Columbia, Vancouver, British Columbia, Canada.
- BC Children's Hospital, Division of Cardiology, Department of Pediatrics, The University of British Columbia, Vancouver, British Columbia, Canada; Center for Cardiovascular Innovation, Division of Cardiology, The Univer…
- Amsterdam UMC, University of Amsterdam, Heart Centre, Department of Clinical and Experimental Cardiology, Amsterdam Cardiovascular Sciences, Heart Failure and Arrhythmias, Amsterdam, the Netherlands; Department of Pedia…
- Amsterdam UMC, University of Amsterdam, Heart Centre, Department of Clinical and Experimental Cardiology, Amsterdam Cardiovascular Sciences, Heart Failure and Arrhythmias, Amsterdam, the Netherlands.
- Department of Pediatrics, Monroe Carell Jr Children's Hospital at Vanderbilt, Vanderbilt University Medical Centre, Nashville, Tennessee.
- Department of Cardiovascular Medicine, Shiga University of Medical Science, Otsu, Japan.
Zitieren
APA
Lamba, A., Roston, T. M., Peltenburg, P. J., Kallas, D., Franciosi, S., Lieve, K. V. V., Kannankeril, P. J., Horie, M., Ohno, S., Brugada, R., Aiba, T., Fischbach, P., Knight, L., Till, J., Kwok, S. Y., Probst, V., Backhoff, D., LaPage, M. J., Batra, A. S., …, & Sanatani, S. (2024). An international multicenter cohort study on implantable cardioverter-defibrillators for the treatment of symptomatic children with catecholaminergic polymorphic ventricular tachycardia. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2024.04.006
Vancouver
Lamba A, Roston TM, Peltenburg PJ, Kallas D, Franciosi S, Lieve KVV, et al. An international multicenter cohort study on implantable cardioverter-defibrillators for the treatment of symptomatic children with catecholaminergic polymorphic ventricular tachycardia. Heart Rhythm. 2024. doi:10.1016/j.hrthm.2024.04.006
BibTeX
@article{Lamba2024,
author = {Lamba, Avani and Roston, Thomas M and Peltenburg, Puck J and Kallas, Dania and Franciosi, Sonia and Lieve, Krystien V V and Kannankeril, Prince J and Horie, Minoru and Ohno, Seiko and Brugada, Ramon and Aiba, Takeshi and Fischbach, Peter and Knight, Linda and Till, Jan and Kwok, Sit-Yee and Probst, Vincent and Backhoff, David and LaPage, Martin J and Batra, Anjan S and Drago, Fabrizio and Haugaa, Kristina and Krahn, Andrew D and Robyns, Tomas and Swan, Heikki and Tavacova, Terezia and van der Werf, Christian and Atallah, Joseph and Borggrefe, Martin and Rudic, Boris and Sarquella-Brugada, Georgia and Chorin, Ehud and Hill, Allison and Kammeraad, Janneke and Kamp, Anna and Law, Ian and Perry, James and Roberts, Jason D and Tisma-Dupanovic, Svjetlana and Semsarian, Christopher and Skinner, Jonathan R and Tfelt-Hansen, Jacob and Denjoy, Isabelle and Leenhardt, Antoine and Schwartz, Peter J and Ackerman, Michael J and Blom, Nico A and Wilde, Arthur A M and Sanatani, Shubhayan},
title = {An international multicenter cohort study on implantable cardioverter-defibrillators for the treatment of symptomatic children with catecholaminergic polymorphic ventricular tachycardia},
journal = {Heart Rhythm},
year = {2024},
doi = {10.1016/j.hrthm.2024.04.006}
}