EUVIMEDEUVIMED entdecken
Crossref

Risk of malignant ventricular arrhythmias in patients with mildly to moderately reduced ejection fraction after permanent pacemaker implantation

Matthew Dai, Connor Peterson, Udi Chorin, Orly Leiva, Moshe Katz, Hend Sliman, Anthony Aizer, Chirag Barbhaiya, Scott Bernstein, Douglas Holmes, Robert Knotts, David Park und 3 weitere

Heart Rhythm · 2024

DOI: 10.1016/j.hrthm.2024.03.026 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Heart Rhythm, 2024. Verfasst von Matthew Dai und 14 weiteren Autor:innen. Beteiligte Einrichtung: Leon H. Charney Division of Cardiology, NYU Langone Health, New York, New York. Hauptthemen laut MEDLINE: Stroke Volume, Tachycardia, Ventricular, Pacemaker, Artificial. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 24 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Many patients with mildly to moderately reduced left ventricular ejection fraction (LVEF) who require permanent pacemaker (PPM) implantation do not have a concurrent indication for implantable cardioverter-defibrillator (ICD) therapy. However, the risk of ventricular tachycardia/ventricular fibrillation (VT/VF) in this population is unknown. OBJECTIVE: The aim of this study was to describe the risk of VT/VF after PPM implantation in patients with mildly to moderately reduced LVEF. METHODS: Retrospective analysis was performed of 243 patients with LVEF between 35% and 49% who underwent PPM placement and did not meet indications for an ICD. The primary end point was occurrence of sustained VT/VF. Competing risks regression was performed to calculate subhazard ratios for the primary end point. RESULTS: Median follow-up was 27 months; 73% of patients were male, average age was 79 ± 10 years, average LVEF was 42% ± 4%, and 70% were New York Heart Association class II or above. Most PPMs were implanted for sick sinus syndrome (34%) or atrioventricular block (50%). Of 243 total patients, 11 (4.5%) met the primary end point of VT/VF. Multivessel coronary artery disease (CAD) was associated with significantly higher rates of VT/VF, with a subhazard ratio of 5.4 (95% CI, 1.5-20.1; P = .01). Of patients with multivessel CAD, 8 of 82 (9.8%) patients met the primary end point for an annualized risk of 4.3% per year. CONCLUSION: Patients with mildly to moderately reduced LVEF and multivessel CAD undergoing PPM implantation are at increased risk for the development of malignant ventricular arrhythmias. Patients in this population may benefit from additional risk stratification for VT/VF and consideration for upfront ICD implantation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Stroke VolumeTachycardia, VentricularPacemaker, ArtificialHumansMaleFemaleAgedRetrospective StudiesFollow-Up StudiesRisk AssessmentRisk FactorsDefibrillators, ImplantableVentricular FibrillationVentricular Function, LeftVentricular Dysfunction, Left

Stichwörter der Autor:innen

Coronary artery diseaseHFmrEFHeart failureICDPPMVentricular arrhythmias

Autor:innen und Institutionen

  • Leon H. Charney Division of Cardiology, NYU Langone Health, New York, New York.
  • Department of Cardiology, Tel-Aviv Sourasky Medical Center, Tel Aviv, Israel.
  • Leon H. Charney Division of Cardiology, NYU Langone Health, New York, New York. Electronic address: Lior.Jankelson@nyulangone.org.

Zitieren

APA

Dai, M., Peterson, C., Chorin, U., Leiva, O., Katz, M., Sliman, H., Aizer, A., Barbhaiya, C., Bernstein, S., Holmes, D., Knotts, R., Park, D., Spinelli, M., Chinitz, L., & Jankelson, L. (2024). Risk of malignant ventricular arrhythmias in patients with mildly to moderately reduced ejection fraction after permanent pacemaker implantation. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2024.03.026

Vancouver

Dai M, Peterson C, Chorin U, Leiva O, Katz M, Sliman H, et al. Risk of malignant ventricular arrhythmias in patients with mildly to moderately reduced ejection fraction after permanent pacemaker implantation. Heart Rhythm. 2024. doi:10.1016/j.hrthm.2024.03.026

BibTeX
@article{Dai2024,
  author = {Dai, Matthew and Peterson, Connor and Chorin, Udi and Leiva, Orly and Katz, Moshe and Sliman, Hend and Aizer, Anthony and Barbhaiya, Chirag and Bernstein, Scott and Holmes, Douglas and Knotts, Robert and Park, David and Spinelli, Michael and Chinitz, Larry and Jankelson, Lior},
  title = {Risk of malignant ventricular arrhythmias in patients with mildly to moderately reduced ejection fraction after permanent pacemaker implantation},
  journal = {Heart Rhythm},
  year = {2024},
  doi = {10.1016/j.hrthm.2024.03.026}
}
Kostenlos starten →