EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyse

Conduction system pacing versus biventricular pacing in heart failure with reduced ejection fraction: A systematic review and meta-analysis of randomized controlled trials

Iuri Ferreira Felix, Michelle Collini, Rafaela Fonseca, Camila Guida, Luciana Armaganijan, Jeffrey Sean Healey, Guilherme Carvalho

Heart Rhythm · 2024-06 · 21 (6) · 881-889

DOI: 10.1016/j.hrthm.2024.02.035 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Heart Rhythm, 2024-06. Verfasst von Iuri Ferreira Felix und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, Mayo Clinic School of Graduate Medical Education, Rochester, Minnesota. Electronic address: ferreirafelix.iuri@mayo.edu. Hauptthemen laut MEDLINE: Cardiac Resynchronization Therapy, Heart Failure, Stroke Volume. Die Arbeit wurde bisher 49-mal zitiert (Crossref) und nennt 35 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Conduction system pacing (CSP) has emerged as a promising alternative to biventricular pacing (BVP) in patients with heart failure with reduced ejection fraction (HFrEF) and ventricular dyssynchrony, but its benefits are uncertain. In this study, we aimed to evaluate clinical outcomes of CSP vs BVP for cardiac resynchronization in patients with HFrEF. PubMed, Scopus, and Cochrane databases were searched for randomized controlled trials comparing CSP to BVP for resynchronization therapy in patients with HFrEF. Heterogeneity was examined with I2 statistics. A random-effects model was used for all outcomes. We included 7 randomized controlled trials with 408 patients, of whom 200 (49%) underwent CSP. Compared to BVP, CSP resulted in a significantly greater reduction in QRS duration (MD -13.34 ms; 95% confidence interval [CI] -24.32 to -2.36, P = .02; I2 = 91%) and New York Heart Association functional class (standardized mean difference [SMD] -0.37; 95% CI -0.69 to -0.05; P = .02; I2 = 41%), and a significant increase in left ventricular ejection fraction (mean difference [MD] 2.06%; 95% CI 0.16 to 3.97; P = .03; I2 = 0%). No statistical difference was noted for left ventricular end-systolic volume (SMD -0.51 mL; 95% CI -1.26 to 0.24; P = .18; I2 = 83%), lead capture threshold (MD -0.08 V; 95% CI -0.42 to 0.27; P = .66; I2 = 66%), and procedure time (MD 5.99 minutes; 95% CI -15.91 to 27.89; P = .59; I2 = 79%). These findings suggest that CSP may have electrocardiographic, echocardiographic, and symptomatic benefits over BVP for patients with HFrEF requiring cardiac resynchronization.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cardiac Resynchronization TherapyHeart FailureStroke VolumeHumansHeart Conduction SystemRandomized Controlled Trials as Topic

Stichwörter der Autor:innen

Biventricular pacingCardiac resynchronizationConduction system pacingHeart failureHis-bundle pacingLeft bundle branch area pacing

Autor:innen und Institutionen

  • Department of Medicine, Mayo Clinic School of Graduate Medical Education, Rochester, Minnesota. Electronic address: ferreirafelix.iuri@mayo.edu.
  • Department of Medicine, Federal University of Paraná, Paraná, Brazil.
  • Department of Medicine, Federal University of Rio Grande do Sul, Porto Alegre, Brazil.
  • Division of Cardiology, Dante Pazzanese Institute of Cardiology, São Paulo, Brazil.
  • Population Health Research Institute, McMaster University, Hamilton, Ontario, Canada.

Zitieren

APA

Ferreira Felix, I., Collini, M., Fonseca, R., Guida, C., Armaganijan, L., Healey, J. S., & Carvalho, G. (2024). Conduction system pacing versus biventricular pacing in heart failure with reduced ejection fraction: A systematic review and meta-analysis of randomized controlled trials. Heart Rhythm, 21(6), 881-889. https://doi.org/10.1016/j.hrthm.2024.02.035

Vancouver

Ferreira Felix I, Collini M, Fonseca R, Guida C, Armaganijan L, Healey JS, et al. Conduction system pacing versus biventricular pacing in heart failure with reduced ejection fraction: A systematic review and meta-analysis of randomized controlled trials. Heart Rhythm. 2024;21(6):881-889. doi:10.1016/j.hrthm.2024.02.035

BibTeX
@article{FerreiraFelix2024,
  author = {Ferreira Felix, Iuri and Collini, Michelle and Fonseca, Rafaela and Guida, Camila and Armaganijan, Luciana and Healey, Jeffrey Sean and Carvalho, Guilherme},
  title = {Conduction system pacing versus biventricular pacing in heart failure with reduced ejection fraction: A systematic review and meta-analysis of randomized controlled trials},
  journal = {Heart Rhythm},
  year = {2024},
  volume = {21},
  number = {6},
  pages = {881--889},
  doi = {10.1016/j.hrthm.2024.02.035}
}
Kostenlos starten →