Validation of the PRAETORIAN score in a large subcutaneous implantable cardioverter-defibrillator collective: Usefulness in clinical routine
Heart Rhythm · 2024
DOI: 10.1016/j.hrthm.2024.02.032 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Heart Rhythm, 2024. Verfasst von Florian Doldi und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department for Cardiology II, Electrophysiology, University Hospital Münster, Münster, Germany. Electronic address: Florian.Doldi@ukmuenster.de. Hauptthemen laut MEDLINE: Defibrillators, Implantable, Ventricular Fibrillation. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
BACKGROUND: To assess the risk of unsuccessful conversion of ventricular fibrillation during defibrillation testing (DFT) with the subcutaneous implantable cardioverter-defibrillator (S-ICD), the PRAETORIAN score has been proposed. OBJECTIVE: The purpose of this study was to validate the PRAETORIAN score in a large S-ICD collective. METHODS: A retrospective single-center analysis of S-ICD patients receiving intraoperative DFT was performed. DFT was performed using a stepwise protocol with 65-J standard polarity, change of polarity, increase to 80 J, and repositioning if necessary. If all DFTs failed, we switched to a transvenous ICD. RESULTS: Overall, 398 patients were analyzed (268 male [67.3%]; mean age 42.4 ± 15.9 years; mean body mass index [BMI] 25.9 ± 4.8 kg/m2). Successful DFT with the first ICD shock was observed in 264 patients (66.3%). One hundred fourteen patients were defibrillated with the second (n = 104) or third (n = 10) DFT after changing shock polarity and/or shock energy. Overall, 20 patients needed at least 3 DFT (ie, 80 J and/or re-positioning). The majority (n = 88 [65.7%]) of DFT failures occurred before 2015 with the first-generation S-ICD. PRAETORIAN score was an independent predictor of DFT failure (odds ratio [OR] 1.007; 95% confidence interval [CI] 1.003-1.011 P ≤.001), while whereas BMI alone was not (P = .31). Presence of hypertrophic cardiomyopathy (HCM) (OR 2.6; 95% CI 1.3-4.4; P = .004) was predictive for at least 1 unsuccessful DFT in our multivariate regression analysis. CONCLUSION: PRAETORIAN score proved to be a useful and valid predictive tool for successful DFT, whereas BMI only had a limited role. Patients with HCM were at increased risk for DFT failure or needed higher DFT energy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department for Cardiology II, Electrophysiology, University Hospital Münster, Münster, Germany. Electronic address: Florian.Doldi@ukmuenster.de.
- Department for Cardiology II, Electrophysiology, University Hospital Münster, Münster, Germany.
- Department for Cardio-Thoracic Surgery, University Hospital Münster, Münster, Germany.
Zitieren
APA
Doldi, F., Frommeyer, G., Löher, A., Ellermann, C., Wolfes, J., Güner, F., Zerbst, M., Engelke, H., Korthals, D., Reinke, F., Eckardt, L., & Willy, K. (2024). Validation of the PRAETORIAN score in a large subcutaneous implantable cardioverter-defibrillator collective: Usefulness in clinical routine. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2024.02.032
Vancouver
Doldi F, Frommeyer G, Löher A, Ellermann C, Wolfes J, Güner F, et al. Validation of the PRAETORIAN score in a large subcutaneous implantable cardioverter-defibrillator collective: Usefulness in clinical routine. Heart Rhythm. 2024. doi:10.1016/j.hrthm.2024.02.032
BibTeX
@article{Doldi2024,
author = {Doldi, Florian and Frommeyer, Gerrit and Löher, Andreas and Ellermann, Christian and Wolfes, Julian and Güner, Fatih and Zerbst, Mathis and Engelke, Hauke and Korthals, Dennis and Reinke, Florian and Eckardt, Lars and Willy, Kevin},
title = {Validation of the PRAETORIAN score in a large subcutaneous implantable cardioverter-defibrillator collective: Usefulness in clinical routine},
journal = {Heart Rhythm},
year = {2024},
doi = {10.1016/j.hrthm.2024.02.032}
}
EUVIMED