EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Enhancing transvenous lead extraction risk prediction: Integrating imaging biomarkers into machine learning models

Vishal S Mehta, YingLiang Ma, Nadeev Wijesuriya, Felicity DeVere, Sandra Howell, Mark K Elliott, Nilanka N Mannkakara, Tatiana Hamakarim, Tom Wong, Hugh O'Brien, Steven Niederer, Reza Razavi und 1 weitere

Heart Rhythm · 2024

DOI: 10.1016/j.hrthm.2024.02.015 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Heart Rhythm, 2024. Verfasst von Vishal S Mehta und 12 weiteren Autor:innen. Beteiligte Einrichtung: Cardiology Department, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom; School of Biomedical Engineering and Imaging Sciences, King…. Hauptthemen laut MEDLINE: Machine Learning, Device Removal. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Wellcome Trust, Wellcome EPSRC Centre for Medical Engineering.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Machine learning (ML) models have been proposed to predict risk related to transvenous lead extraction (TLE). OBJECTIVE: The purpose of this study was to test whether integrating imaging data into an existing ML model increases its ability to predict major adverse events (MAEs; procedure-related major complications and procedure-related deaths) and lengthy procedures (≥100 minutes). METHODS: We hypothesized certain features-(1) lead angulation, (2) coil percentage inside the superior vena cava (SVC), and (3) number of overlapping leads in the SVC-detected from a pre-TLE plain anteroposterior chest radiograph (CXR) would improve prediction of MAE and long procedural times. A deep-learning convolutional neural network was developed to automatically detect these CXR features. RESULTS: A total of 1050 cases were included, with 24 MAEs (2.3%) . The neural network was able to detect (1) heart border with 100% accuracy; (2) coils with 98% accuracy; and (3) acute angle in the right ventricle and SVC with 91% and 70% accuracy, respectively. The following features significantly improved MAE prediction: (1) ≥50% coil within the SVC; (2) ≥2 overlapping leads in the SVC; and (3) acute lead angulation. Balanced accuracy (0.74-0.87), sensitivity (68%-83%), specificity (72%-91%), and area under the curve (AUC) (0.767-0.962) all improved with imaging biomarkers. Prediction of lengthy procedures also improved: balanced accuracy (0.76-0.86), sensitivity (75%-85%), specificity (63%-87%), and AUC (0.684-0.913). CONCLUSION: Risk prediction tools integrating imaging biomarkers significantly increases the ability of ML models to predict risk of MAE and long procedural time related to TLE.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Machine LearningDevice RemovalHumansMaleFemaleRisk AssessmentAgedDefibrillators, ImplantableRetrospective StudiesVena Cava, SuperiorMiddle AgedNeural Networks, ComputerBiomarkers

Stichwörter der Autor:innen

Artificial intelligenceComplicationsComputer visionMachine LearningRisk predictionTransvenous lead extraction

Substanzen

Biomarkers

Autor:innen und Institutionen

  • Cardiology Department, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom; School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom. Electronic address: vishal.…
  • School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom; School of Computing Sciences, University of East Anglia, Norwich, United Kingdom.
  • Cardiology Department, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom; School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.
  • Cardiology Department, Guy's and St Thomas' NHS Foundation Trust, London, United Kingdom; School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom; National Heart and Lung Ins…
  • School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.
  • School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom; National Heart and Lung Institute, Imperial College London, Hammersmith Hospital, London, United Kingdom.

Förderung

  • Wellcome Trust
  • Wellcome EPSRC Centre for Medical Engineering

Zitieren

APA

Mehta, V. S., Ma, Y., Wijesuriya, N., DeVere, F., Howell, S., Elliott, M. K., Mannkakara, N. N., Hamakarim, T., Wong, T., O'Brien, H., Niederer, S., Razavi, R., & Rinaldi, C. A. (2024). Enhancing transvenous lead extraction risk prediction: Integrating imaging biomarkers into machine learning models. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2024.02.015

Vancouver

Mehta VS, Ma Y, Wijesuriya N, DeVere F, Howell S, Elliott MK, et al. Enhancing transvenous lead extraction risk prediction: Integrating imaging biomarkers into machine learning models. Heart Rhythm. 2024. doi:10.1016/j.hrthm.2024.02.015

BibTeX
@article{Mehta2024,
  author = {Mehta, Vishal S and Ma, YingLiang and Wijesuriya, Nadeev and DeVere, Felicity and Howell, Sandra and Elliott, Mark K and Mannkakara, Nilanka N and Hamakarim, Tatiana and Wong, Tom and O'Brien, Hugh and Niederer, Steven and Razavi, Reza and Rinaldi, Christopher A},
  title = {Enhancing transvenous lead extraction risk prediction: Integrating imaging biomarkers into machine learning models},
  journal = {Heart Rhythm},
  year = {2024},
  doi = {10.1016/j.hrthm.2024.02.015}
}
Kostenlos starten →