Sinus rhythm QRS morphology reflects right ventricular activation and anatomical ventricular tachycardia isthmus conduction in repaired tetralogy of Fallot
Heart Rhythm · 2023
DOI: 10.1016/j.hrthm.2023.08.020 ↗Kurz gefasst
Fachartikel in der Zeitschrift Heart Rhythm, 2023. Verfasst von Jeremy P Moore und 7 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Department of Medicine, Ahmanson/UCLA Adult Congenital Heart Disease Center, Los Angeles, California; UCLA Cardiac Arrhythmia…. Hauptthemen laut MEDLINE: Tetralogy of Fallot, Tachycardia, Ventricular, Heart Septal Defects, Ventricular. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 13 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Patients with repaired tetralogy of Fallot (TOF) are at risk for ventricular tachycardia (VT) related to well-described anatomical isthmuses. OBJECTIVE: The purpose of this study was to explore QRS morphology as an indicator of anatomical isthmus conduction. METHODS: Patients with repaired TOF and complete right bundle branch block referred for transcatheter pulmonary valve replacement (PVR) or presenting with sustained VT underwent comprehensive 3-dimensional mapping in sinus rhythm. Electrocardiographic characteristics were compared to right ventricular (RV) activation and anatomical isthmus conduction properties. RESULTS: Twenty-two patients (19 pre-pulmonary valve replacement and 3 clinical VT) underwent comprehensive 3-dimensional mapping (median 39 years; interquartile range [IQR] 27-48 years; 12 [55%] male). Septal RV activation (median 40 ms; IQR 34-46 ms) corresponded to the nadir in lead V1 and free wall activation (median 71 ms; IQR 64-81 ms) to the transition point in the upstroke of the R' wave. Patients with isthmus block between the pulmonary annulus and the ventricular septal defect patch and between the ventricular septal defect patch and the tricuspid annulus (when present), were more likely to demonstrate lower amplitude R' waves in lead V1 (5.8 mV vs 9.4 mV; P = .005), QRS fragmentation in lead V1 (15 [94%] vs 2 [13%]; P < .001), and terminal S waves in lead aVF (15 [94%] vs 6 [40%]; P < .001) than those with intact conduction. During catheter ablation, these QRS changes developed during isthmus block. CONCLUSION: For patients with repaired TOF, the status of septal isthmus conduction was evident from sinus rhythm QRS morphology. Low-amplitude, fragmented R' waves in lead V1 and terminal S waves in the inferior leads were related to septal isthmus conduction abnormalities, providing a mechanistic link between RV activation and common electrocardiographic findings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Cardiology, Department of Medicine, Ahmanson/UCLA Adult Congenital Heart Disease Center, Los Angeles, California; UCLA Cardiac Arrhythmia Center, UCLA Health System, Los Angeles, California; Division of Card…
- Montreal Heart Institute, Université de Montréal, Montreal, Quebec, Canada.
- Université Paris Cité, Inserm, PARCC, Paris, France; Adult Congenital Heart Disease Medico-Surgical Unit, European Georges Pompidou Hospital, Paris, France; M3C-Necker, Hôpital Universitaire Necker-Enfants malades, APHP…
- Cardiac Electrophysiology Unit, European Georges Pompidou Hospital, Paris, France; Louis Pradel Hospital, Hospices Civils de Lyon, Université Lyon 1 Claude Bernard, Lyon, France.
- David Geffen School of Medicine, UCLA, Los Angeles, California.
- Division of Cardiology, Department of Pediatrics, UCLA Health System, Los Angeles, California.
Zitieren
APA
Moore, J. P., Shannon, K. M., Khairy, P., Waldmann, V., Bessière, F., Burrows, A., Su, J., & Shivkumar, K. (2023). Sinus rhythm QRS morphology reflects right ventricular activation and anatomical ventricular tachycardia isthmus conduction in repaired tetralogy of Fallot. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2023.08.020
Vancouver
Moore JP, Shannon KM, Khairy P, Waldmann V, Bessière F, Burrows A, et al. Sinus rhythm QRS morphology reflects right ventricular activation and anatomical ventricular tachycardia isthmus conduction in repaired tetralogy of Fallot. Heart Rhythm. 2023. doi:10.1016/j.hrthm.2023.08.020
BibTeX
@article{Moore2023,
author = {Moore, Jeremy P and Shannon, Kevin M and Khairy, Paul and Waldmann, Victor and Bessière, Francis and Burrows, Austin and Su, Jonathan and Shivkumar, Kalyanam},
title = {Sinus rhythm QRS morphology reflects right ventricular activation and anatomical ventricular tachycardia isthmus conduction in repaired tetralogy of Fallot},
journal = {Heart Rhythm},
year = {2023},
doi = {10.1016/j.hrthm.2023.08.020}
}
EUVIMED