Improved outcomes of conduction system pacing in heart failure with reduced ejection fraction: A systematic review and meta-analysis
Heart Rhythm · 2023-08 · 20 (8) · 1178-1187
DOI: 10.1016/j.hrthm.2023.05.010 ↗Kurz gefasst
Metaanalyse in der Zeitschrift Heart Rhythm, 2023-08. Verfasst von Julian Gin und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Austin Health, Melbourne, Victoria, Australia. Hauptthemen laut MEDLINE: Cardiac Resynchronization Therapy, Heart Failure. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 44 Literaturangaben. Gefördert von: National Health and Medical Research Council, National Heart Foundation of Australia.
Themen: Herzinsuffizienz
Abstract (Originalsprache)
Conduction system pacing (CSP)-His bundle pacing (HBP) and left bundle branch area pacing (LBBAP)-are emerging alternatives to biventricular pacing (BVP) for cardiac resynchronization therapy (CRT) in heart failure. However, evidence is largely limited to small and observational studies. We conducted a meta-analysis including a total of 15 randomized controlled trials (RCTs) and non-RCTs that compare CSP (HBP and LBBAP) with BVP in patients with CRT indications. We assessed the mean differences in QRS duration (QRSd), pacing threshold, left ventricular ejection fraction (LVEF), and New York Heart Association (NYHA) class score. CSP resulted in a pooled mean QRSd improvement of -20.3 ms (95% confidence interval [CI] -26.1 to -14.5 ms; P < .05; I2= 87.1%) vs BVP. For LVEF, a weighted mean increase of 5.2% (95% CI 3.5%-6.9%; P < .05; I2 = 55.6) was observed after CSP vs BVP. The mean NYHA score was reduced by -0.40 (95% CI -0.6 to -0.2; P < .05; I2 = 61.7) after CSP vs BVP. A subgroup analysis of outcomes stratified by LBBAP and HBP demonstrated statistically significant weighted mean improvements of QRSd and LVEF with both CSP modalities compared with BVP. LBBAP resulted in NYHA improvement compared with BVP, without differences between CSP subgroups. LBBAP is associated with a significantly lowered mean pacing threshold of -0.51 V (95% CI -0.68 to -0.38 V) while HBP had increased the mean threshold (0.62 V; 95% CI -0.03 to 1.26 V) compared with BVP; however, this was associated with significant heterogeneity. Overall, both CSP techniques are feasible and effective CRT alternatives for heart failure. Further RCTs are needed to establish long-term efficacy and safety.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Austin Health, Melbourne, Victoria, Australia.
- Department of Cardiology, Austin Health, Melbourne, Victoria, Australia; Department of Cardiology, Northern Health, Melbourne, Victoria, Australia; Department of Medicine, The University of Melbourne, Melbourne, Victori…
- Department of Cardiology, Alfred Health, Melbourne, Victoria, Australia.
- Department of Cardiology, Macquarie University Hospital, Sydney, New South Wales, Australia.
- Department of Cardiology, Northern Health, Melbourne, Victoria, Australia; Department of Medicine, The University of Melbourne, Melbourne, Victoria, Australia.
- Department of Cardiology, Austin Health, Melbourne, Victoria, Australia; Department of Medicine, The University of Melbourne, Melbourne, Victoria, Australia.
Förderung
- National Health and Medical Research Council
- National Heart Foundation of Australia
Zitieren
APA
Gin, J., Chow, C. L., Voskoboinik, A., Nalliah, C., Wong, C., Van Gaal, W., Farouque, O., Mohamed, U., Lim, H. S., Kalman, J. M., & Wong, G. R. (2023). Improved outcomes of conduction system pacing in heart failure with reduced ejection fraction: A systematic review and meta-analysis. Heart Rhythm, 20(8), 1178-1187. https://doi.org/10.1016/j.hrthm.2023.05.010
Vancouver
Gin J, Chow CL, Voskoboinik A, Nalliah C, Wong C, Van Gaal W, et al. Improved outcomes of conduction system pacing in heart failure with reduced ejection fraction: A systematic review and meta-analysis. Heart Rhythm. 2023;20(8):1178-1187. doi:10.1016/j.hrthm.2023.05.010
BibTeX
@article{Gin2023,
author = {Gin, Julian and Chow, Chee Loong and Voskoboinik, Alex and Nalliah, Chrishan and Wong, Chiew and Van Gaal, William and Farouque, Omar and Mohamed, Uwais and Lim, Han S and Kalman, Jonathan M and Wong, Geoffrey R},
title = {Improved outcomes of conduction system pacing in heart failure with reduced ejection fraction: A systematic review and meta-analysis},
journal = {Heart Rhythm},
year = {2023},
volume = {20},
number = {8},
pages = {1178--1187},
doi = {10.1016/j.hrthm.2023.05.010}
}
EUVIMED