EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

High-frequency JET versus conventional ventilation for pulmonary veins isolation: A prospective, randomised, single blind study The JET-AF study

Benoit Robaye, Olivier Xhaët, Quentin Delhez, Michaël Hardy, David de Azevedo, Arnaud Gilson, Benoit Bihin, Nicolas Mulquin, Benoit Collet, BMT, Fabien Dormal, Philippe Purnode, Adrien Maseri

Heart Rhythm O2 · 2026-11

DOI: 10.1016/j.hroo.2026.10.032 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Heart Rhythm O2, 2026-11. Verfasst von Benoit Robaye, Olivier Xhaët, Quentin Delhez, Michaël Hardy, David de Azevedo, Arnaud Gilson, Benoit Bihin, Nicolas Mulquin, Benoit Collet, BMT und 1 weiteren Autor:innen. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Atrial fibrillation (AF) ablation by pulmonary veins isolation (PVI) is an increasingly important part of AF treatment strategies. As demand for PVI continues to grow, shortening this process is an important way of making it accessible to all. During PVI, the instability of the catheter due to respiratory movements can make the procedure longer and less effective.

Objectives

To evaluate the potential time-saving benefits, the safety and efficacy of high-frequency JET ventilation (HFJV), a technique that almost abolishes respiratory movements of the chest, during radiofrequency PVI.

Methods

We conducted a prospective, single-center, randomised, 1:1, single-blind, parallel trial comparing the use of HFJV with conventional ventilation in patients undergoing a first PVI for either paroxysmal or persistent AF. The primary endpoint was the reduction in total procedure time. Safety evaluation criteria were the absence of complications (especially respiratory complications) due to the use of HFJV. One year success rates (absence of AF/atrial tachycardia recurrence > 30 sec) were also registered.

Results

Total procedure time was shorter in the HFVJ group than in the control group (79 vs 90 minutes, p=0.0001). No adverse event related to the use of HFJV has occurred. Clinical one year success (assessed with Holter ECG) did not differ between groups.

Conclusion

Compared to conventional ventilation, high-frequency JET ventilation (HFJV) significantly shortens pulmonary vein isolations without compromising safety nor efficacy. HFJV has the potential to enhance the efficiency and some outcomes of PVI and can easily work in synergy with other innovative ablation techniques.

Zitieren

APA

BMT, B. R. O. X. Q. D. M. H. D. D. A. A. G. B. B. N. M. B. C., & Maseri, F. D. P. P. A. (2026). High-frequency JET versus conventional ventilation for pulmonary veins isolation: A prospective, randomised, single blind study The JET-AF study. Heart Rhythm O2. https://doi.org/10.1016/j.hroo.2026.10.032

Vancouver

BMT BROXQDMHDDAAGBBNMBC, Maseri FDPPA. High-frequency JET versus conventional ventilation for pulmonary veins isolation: A prospective, randomised, single blind study The JET-AF study. Heart Rhythm O2. 2026. doi:10.1016/j.hroo.2026.10.032

BibTeX
@article{BMT2026,
  author = {BMT, Benoit Robaye, Olivier Xhaët, Quentin Delhez, Michaël Hardy, David de Azevedo, Arnaud Gilson, Benoit Bihin, Nicolas Mulquin, Benoit Collet, and Maseri, Fabien Dormal, Philippe Purnode, Adrien},
  title = {High-frequency JET versus conventional ventilation for pulmonary veins isolation: A prospective, randomised, single blind study The JET-AF study},
  journal = {Heart Rhythm O2},
  year = {2026},
  doi = {10.1016/j.hroo.2026.10.032}
}
Kostenlos starten →