Real-world use of insertable cardiac monitor remote programming: A multicenter European experience
Heart Rhythm O2 · 2025-11 · 6 (11) · 1735-1742
DOI: 10.1016/j.hroo.2025.08.035 ↗Kurz gefasst
Fachartikel in der Zeitschrift Heart Rhythm O2, 2025-11. Verfasst von Samir Fareh und 19 weiteren Autor:innen. Beteiligte Einrichtung: Hôpital de la Croix-Rousse et Hôpital Lyon Sud, Hospices Civils de Lyon, Lyon, France. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Boston Scientific Japan, Johnson and Johnson.
Abstract (Originalsprache)
Background
Insertable cardiac monitors (ICMs) enable continuous arrhythmia monitoring but generate high transmission volumes, increasing clinical workload. The LUX-Dx ICM (Boston Scientific) allows remote reprogramming of device alert settings, potentially reducing in-office visits.
Objective
This study aimed to evaluate the real-world use of remote reprogramming after its initial commercialization in Europe and its impact on transmission burden.
Methods
Deidentified data were collected from 697 consecutive patients across 23 European centers between 2022 and 2024.
Results
Syncope (48%) was the most frequent indication for ICM implantation. Patients were followed for a median of 9 months (25th-75th percentile 4-13). A total of 401 reprogramming events (0.8 per patient-year) occurred in 230 ICMs, with 38% (95% confidence interval 34-43) of devices reprogrammed within 1 year. Of these, 156 (39%) were performed remotely. The overall transmission rate was 3.0 per patient-month (95% confidence interval 2.9-3.1): alert transmissions (64%), scheduled transmissions (31%), patient-initiated interrogations (4%), and clinician-initiated interrogations (1%). The rate of recorded episodes varied significantly by indication (P < .001), with bradycardia the most frequent across groups. Reprogramming significantly reduced transmission rates (median 57%; 25th-75th percentile 4-86), alerts (78%; 25th-75th percentile 11-96), and recorded episodes (91%; 25th-75th percentile 47-99) (all P < .001).
Conclusion
ICM reprogramming plays a key role in optimizing device performance and reducing remote monitoring burden. Currently used in 39% of cases, remote reprogramming holds potential for broader adoption to minimize in-office visits. Efficiency may be further improved by transitioning to an alert-based monitoring strategy and eliminating scheduled transmissions.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Hôpital de la Croix-Rousse et Hôpital Lyon Sud, Hospices Civils de Lyon, Lyon, France.
- Pineta Grande" Hospital, Castel Volturno, CE, Italy.
- Clinica Sanatrix, Naples, Italy.
- Ospedale Maggiore Di Lodi, Lodi, Italy.
- Ospedale Sacro Cuore - Don Calabria, Negrar (VR), Italy.
- Fatebenefratelli Hospital, Naples, Italy.
Förderung
- Boston Scientific Japan
- Johnson and Johnson
Zitieren
APA
Fareh, S., Nardi, S., Argenziano, L., Poggio, L., Costa, A., Scala, F., Diamante, A., Luzzi, G., Lavalle, C., Checchi, L., Magnocavallo, M., Silvetti, M. S., Porcelli, D., Gianfrancesco, D., Boncompagni, A., Charles, P., Marino, V., Campari, M., Valsecchi, S., & Conte, G. (2025). Real-world use of insertable cardiac monitor remote programming: A multicenter European experience. Heart Rhythm O2, 6(11), 1735-1742. https://doi.org/10.1016/j.hroo.2025.08.035
Vancouver
Fareh S, Nardi S, Argenziano L, Poggio L, Costa A, Scala F, et al. Real-world use of insertable cardiac monitor remote programming: A multicenter European experience. Heart Rhythm O2. 2025;6(11):1735-1742. doi:10.1016/j.hroo.2025.08.035
BibTeX
@article{Fareh2025,
author = {Fareh, Samir and Nardi, Stefano and Argenziano, Luigi and Poggio, Luca and Costa, Alessandro and Scala, Fernando and Diamante, Alessandro and Luzzi, Giovanni and Lavalle, Carlo and Checchi, Luca and Magnocavallo, Michele and Silvetti, Massimo Stefano and Porcelli, Daniele and Gianfrancesco, Domenico and Boncompagni, Andrea and Charles, Paul and Marino, Vittoria and Campari, Monica and Valsecchi, Sergio and Conte, Giulio},
title = {Real-world use of insertable cardiac monitor remote programming: A multicenter European experience},
journal = {Heart Rhythm O2},
year = {2025},
volume = {6},
number = {11},
pages = {1735--1742},
doi = {10.1016/j.hroo.2025.08.035}
}
EUVIMED