Accuracy and efficiency of artificial Intelligence–Assisted three-dimensional liver volumetry in living donor evaluation based on real world prospective data
HPB · 2026
DOI: 10.1016/j.hpb.2025.11.014 ↗Kurz gefasst
Fachartikel in der Zeitschrift HPB, 2026. Verfasst von Hayeon Do und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea. Hauptthemen laut MEDLINE: Living Donors, Liver Transplantation, Liver, Imaging, Three-Dimensional. Die Arbeit nennt 21 Literaturangaben. Gefördert von: National Research Foundation, Samsung Medical Center, Sungkyunkwan University, Ministry of Science and ICT, South Korea.
Abstract (Originalsprache)
BACKGROUND: Accurate liver volumetry is crucial for safe living donor liver transplantation (LDLT). Manual segmentation is time-consuming and delays surgical planning. Artificial intelligence (AI) enables automated 3D volumetry, improving workflow efficiency and accuracy. METHODS: This retrospective study analyzed 583 living liver donor candidates who underwent preoperative CT volumetry between January 2023 and February 2025 at Samsung Medical Center. Donors were grouped into conventional 2D manual segmentation and AI-based 3D volumetry. Volumetric data before and after AI refinement were compared with intraoperative graft weights. Turnaround time, agreement between AI and manual results, and prediction accuracy were assessed. Subgroup analyses excluded donors with segmental resections or >5 % preoperative weight loss. RESULTS: Of 583 donors, 271 underwent surgery, and 239 met inclusion criteria. The AI group had shorter turnaround times (1.5 ± 1.5 vs. 4.2 ± 3.6 days; p < 0.001). AI and manually edited volumes correlated strongly (R2 = 0.992; mean difference 23.7 ± 39.5 mL). After exclusions, AI-based volumetry showed superior predictive performance (R2 = 0.818; median error 54.0 mL) versus conventional methods (R2 = 0.707; median error 65.0 mL). CONCLUSIONS: AI-assisted 3D volumetry enables fast, accurate graft volume estimation, reducing processing time and manual effort in LDLT. CLINICAL TRIAL REGISTRATION: Not applicable.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea.
- Department of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea. Electronic address: jsrrules@gmail.com.
Förderung
- National Research Foundation
- Samsung Medical Center, Sungkyunkwan University
- Ministry of Science and ICT, South Korea
Zitieren
APA
Do, H., Baik, J., Gwon, S. M., Lee, E., Ryu, Y., Kim, B., Lim, S., Oh, N., Rhu, J., Choi, G. S., & Kim, J. (2026). Accuracy and efficiency of artificial Intelligence–Assisted three-dimensional liver volumetry in living donor evaluation based on real world prospective data. HPB. https://doi.org/10.1016/j.hpb.2025.11.014
Vancouver
Do H, Baik J, Gwon SM, Lee E, Ryu Y, Kim B, et al. Accuracy and efficiency of artificial Intelligence–Assisted three-dimensional liver volumetry in living donor evaluation based on real world prospective data. HPB. 2026. doi:10.1016/j.hpb.2025.11.014
BibTeX
@article{Do2026,
author = {Do, Hayeon and Baik, Jiyoung and Gwon, Suk Min and Lee, Eunjin and Ryu, Youngju and Kim, Bogeun and Lim, Soyoung and Oh, Namkee and Rhu, Jinsoo and Choi, Gyu-Seong and Kim, Jongman},
title = {Accuracy and efficiency of artificial Intelligence–Assisted three-dimensional liver volumetry in living donor evaluation based on real world prospective data},
journal = {HPB},
year = {2026},
doi = {10.1016/j.hpb.2025.11.014}
}
EUVIMED