Clinical Outcomes of Māori and Pacific Implantable Cardioverter Defibrillator Recipients in Aotearoa New Zealand (ANZACS-QI 87)
Heart, Lung and Circulation · 2026-11 · 35 (11) · 1626-1633
DOI: 10.1016/j.hlc.2026.04.013 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Heart, Lung and Circulation, 2026-11. Verfasst von Fang Shawn Foo und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, North Shore Hospital, Auckland, New Zealand. Electronic address: shawnfoo@icloud.com. Hauptthemen laut MEDLINE: Defibrillators, Implantable, Heart Failure, Registries. Die Arbeit nennt 18 Literaturangaben. Gefördert von: University of Auckland.
Abstract (Originalsprache)
BACKGROUND: This study aims to compare the clinical characteristics and outcomes of Māori and Pacific people receiving implantable cardioverter defibrillators (ICD) with other ethnicities. METHOD: All patients who received an ICD in Aotearoa New Zealand between 2016 and 2020 were identified from a national registry for cardiac implantable electronic devices. Patients with infiltrative cardiomyopathies, congenital heart disease and channelopathies were excluded. The primary outcome was all-cause mortality. Secondary outcomes were cardiovascular disease (CVD) mortality, non-CVD mortality, heart failure (HF) hospitalisation and ventricular arrhythmia (VA) hospitalisation. Log-rank tests on Kaplan-Meier (KM) curves and 4-year KM event rates were reported. Multivariable Cox regression models were performed to determine the hazard ratio (HR) of all-cause mortality in ethnic subgroups compared to European/other. RESULTS: There were 1,990 patients with a mean follow-up of 4.0±1.5 years. Compared to other ethnicities, Māori and Pacific patients were younger (Māori: 59 years, Pacific: 56 years, Asian: 60 years, European/other: 65 years; p
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, North Shore Hospital, Auckland, New Zealand. Electronic address: shawnfoo@icloud.com.
- Ngāi Tahu Māori Health Research Unit, University of Otago, Dunedin, New Zealand.
- Section of Epidemiology and Biostatistics, School of Population Health, University of Auckland, Auckland, New Zealand.
- Department of Cardiology, Middlemore Hospital, Otahuhu, Auckland, New Zealand.
- Department of Cardiology, Christchurch Hospital, Christchurch, New Zealand; University of Otago, Christchurch, New Zealand.
- Waikato Clinical School, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand; Department of Cardiology, Waikato Hospital, Hamilton, New Zealand.
Förderung
- University of Auckland
Zitieren
APA
Foo, F. S., Crengle, S., Lee, M., Harrison, W., Clare, G. C., Stiles, M. K., Gavin, A., Webber, M., Martin, A., Jackson, R., & Kerr, A. J. (2026). Clinical Outcomes of Māori and Pacific Implantable Cardioverter Defibrillator Recipients in Aotearoa New Zealand (ANZACS-QI 87). Heart, Lung and Circulation, 35(11), 1626-1633. https://doi.org/10.1016/j.hlc.2026.04.013
Vancouver
Foo FS, Crengle S, Lee M, Harrison W, Clare GC, Stiles MK, et al. Clinical Outcomes of Māori and Pacific Implantable Cardioverter Defibrillator Recipients in Aotearoa New Zealand (ANZACS-QI 87). Heart, Lung and Circulation. 2026;35(11):1626-1633. doi:10.1016/j.hlc.2026.04.013
BibTeX
@article{Foo2026,
author = {Foo, Fang Shawn and Crengle, Sue and Lee, Mildred and Harrison, Wil and Clare, Geoffrey C and Stiles, Martin K and Gavin, Andrew and Webber, Matthew and Martin, Andrew and Jackson, Rod and Kerr, Andrew J},
title = {Clinical Outcomes of Māori and Pacific Implantable Cardioverter Defibrillator Recipients in Aotearoa New Zealand (ANZACS-QI 87)},
journal = {Heart, Lung and Circulation},
year = {2026},
volume = {35},
number = {11},
pages = {1626--1633},
doi = {10.1016/j.hlc.2026.04.013}
}
EUVIMED