EUVIMEDEUVIMED entdecken
Multizentrische Studie

Physician Perspectives on the Utility of Pre/Post-Ductal Oxygen Saturation Monitoring in the Management of Neonates With Congenital Heart Disease

Beau Redwood, Adrian Tarca, Zac Dempsey, Rebecca Thomas, Cameron Seaman, Simon Erickson, Stephen Shipton, Deane Yim

Heart, Lung and Circulation · 2026-07 · 35 (7) · 930-938

DOI: 10.1016/j.hlc.2025.12.028 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Heart, Lung and Circulation, 2026-07. Verfasst von Beau Redwood und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Paediatric Cardiology, Perth Children's Hospital, Perth, WA, Australia. Hauptthemen laut MEDLINE: Heart Defects, Congenital, Oxygen Saturation, Oximetry, Oxygen. Die Arbeit nennt 22 Literaturangaben. Gefördert von: Cardiac Society of Australia and New Zealand.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND Simultaneous pre/post-ductal oxygen saturation measurements are routinely performed in neonates with suspected congenital heart disease (CHD) however, there is significant variability in physician practices and perceived clinical utility of differential oxygen saturation monitoring in individual CHD lesions. METHOD A survey of Australian and New Zealand paediatric cardiologists, neonatologists and paediatric intensivists was conducted to obtain multi-centre, multi-disciplinary physician opinion regarding the utility of pre/post-ductal oxygen saturation monitoring in various clinical situations. RESULTS Overall, 111 responses were received, 32 from paediatric cardiologists, 61 from neonatologists and 18 from paediatric intensivists. In neonates with any form of CHD, 38.7% of participants reported that simultaneous pre/post-ductal oxygen saturation monitoring was often/always useful, 51.4% reported sometimes useful, and 9.9% reported never/rarely useful. There were variations in practice within and between specialities, though the overall differences in utility between specialties were not statistically significant. Participants reported the greatest utility in transposition of the great arteries with intact ventricular septum (TGA/IVS), left heart obstructive lesions and persistent pulmonary hypertension (PPHN), and the least utility in intracardiac shunts, truncus arteriosus, obstructed total anomalous pulmonary venous drainage and right heart obstructive lesions. CONCLUSIONS Pre/post-ductal oxygen saturation monitoring in neonates with CHD can provide useful clinical information regarding patient physiology in select lesions where a differential might occur, including left heart obstructive lesions, TGA/IVS and PPHN. Opinion and practice among paediatric cardiologists, neonatologists and paediatric intensivists regarding its utility is variable and lesion-dependent, overall and within specialties. We suggest the utility of pre/post-ductal oxygen saturation monitoring is limited to specific lesions and should not be used in all neonates with CHD.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart Defects, CongenitalOxygen SaturationOximetryOxygenHumansInfant, NewbornFemaleMaleAustraliaMonitoring, PhysiologicNew Zealand

Stichwörter der Autor:innen

Congenital heart diseaseDifferential cyanosisOxygen saturation

Substanzen

Oxygen

Autor:innen und Institutionen

  • Department of Paediatric Cardiology, Perth Children's Hospital, Perth, WA, Australia.
  • Department of Paediatric and Congenital Cardiology, Starship Children's Hospital, Auckland, New Zealand.
  • Department of Biostatistics, The Kids Research Institute Australia, Perth, WA, Australia.
  • Department of Neonatology, Perth Children's Hospital, Perth, WA, Australia.
  • Department of Paediatric Critical Care, Perth Children's Hospital, Perth, WA, Australia.
  • Department of Paediatric Cardiology, Perth Children's Hospital, Perth, WA, Australia. Electronic address: Deane.Yim@health.wa.gov.au.

Förderung

  • Cardiac Society of Australia and New Zealand

Zitieren

APA

Redwood, B., Tarca, A., Dempsey, Z., Thomas, R., Seaman, C., Erickson, S., Shipton, S., & Yim, D. (2026). Physician Perspectives on the Utility of Pre/Post-Ductal Oxygen Saturation Monitoring in the Management of Neonates With Congenital Heart Disease. Heart, Lung and Circulation, 35(7), 930-938. https://doi.org/10.1016/j.hlc.2025.12.028

Vancouver

Redwood B, Tarca A, Dempsey Z, Thomas R, Seaman C, Erickson S, et al. Physician Perspectives on the Utility of Pre/Post-Ductal Oxygen Saturation Monitoring in the Management of Neonates With Congenital Heart Disease. Heart, Lung and Circulation. 2026;35(7):930-938. doi:10.1016/j.hlc.2025.12.028

BibTeX
@article{Redwood2026,
  author = {Redwood, Beau and Tarca, Adrian and Dempsey, Zac and Thomas, Rebecca and Seaman, Cameron and Erickson, Simon and Shipton, Stephen and Yim, Deane},
  title = {Physician Perspectives on the Utility of Pre/Post-Ductal Oxygen Saturation Monitoring in the Management of Neonates With Congenital Heart Disease},
  journal = {Heart, Lung and Circulation},
  year = {2026},
  volume = {35},
  number = {7},
  pages = {930--938},
  doi = {10.1016/j.hlc.2025.12.028}
}
Kostenlos starten →