Effects of Transradial Catheterisation on Radial Artery Bypass Graft Patency: A Systematic Review and Meta-Analysis
Heart, Lung and Circulation · 2026-03
DOI: 10.1016/j.hlc.2025.12.003 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Heart, Lung and Circulation, 2026-03. Verfasst von Yantong Wang und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Translational Medicine, Monash University, Melbourne, Vic, Australia; Department of Surgery, Monash University, Melbourne, Vic, Australia. Hauptthemen laut MEDLINE: Radial Artery, Coronary Artery Bypass, Vascular Patency, Cardiac Catheterization. Die Arbeit nennt 21 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND Transradial catheterisation is the default approach of coronary angiography, and the radial artery (RA) is a popular conduit choice for coronary artery bypass grafting (CABG). Whether a previously catheterised RA (CRA) remains an optimal bypass conduit for CABG is uncertain. This systematic review and meta-analysis sought to evaluate the previous CRA bypass graft patency. METHOD A systematic search is conducted in MEDLINE, Embase, and Scopus for comparative studies of CRA versus non-CRA (NCRA) grafts. The primary outcome of this study was RA graft patency. Random-effects models generated pooled effect sizes with heterogeneity assessed by I2; small-study effects were examined with funnel plot/Egger's test, and influence analyses were performed in the meta-analysis. RESULTS Of the 1,661 studies screened, four observational studies of 400 patients (175 CRA and 379 NCRA grafts) were included in the analysis. Across the included studies, the mean time from catheterisation to CABG was 27.4±16.0 days; the mean follow-up imaging was conducted at 2.06±1.88 years. CRA graft patency was lower than NCRA (73.2% vs 83.9%), and the pooled odds of graft failure were higher with CRA (odds ratio 1.82; 95% confidence interval 1.26-2.61; p=0.001; I2=33%). There were no significant small-study biases detected on planned assessments. CONCLUSIONS Prior transradial catheterisation is associated with reduced patency of RA bypass grafts. Surgeons should exercise caution when selecting CRA for critical targets, and prospective controlled data are needed to define patient and procedural modifiers of risk.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Translational Medicine, Monash University, Melbourne, Vic, Australia; Department of Surgery, Monash University, Melbourne, Vic, Australia.
- Department of Cardiac Surgery, Austin Health, Heidelberg, Vic, Australia.
- Department of Cardiothoracic Surgery and Transplantation, The Alfred, Melbourne, Vic, Australia.
- Department of Surgery, Monash University, Melbourne, Vic, Australia; Department of Cardiothoracic Surgery and Transplantation, The Alfred, Melbourne, Vic, Australia. Electronic address: S.Marasco@alfred.org.au.
Zitieren
APA
Wang, Y., Sharma, V., Vu, T., & Marasco, S. F. (2026). Effects of Transradial Catheterisation on Radial Artery Bypass Graft Patency: A Systematic Review and Meta-Analysis. Heart, Lung and Circulation. https://doi.org/10.1016/j.hlc.2025.12.003
Vancouver
Wang Y, Sharma V, Vu T, Marasco SF. Effects of Transradial Catheterisation on Radial Artery Bypass Graft Patency: A Systematic Review and Meta-Analysis. Heart, Lung and Circulation. 2026. doi:10.1016/j.hlc.2025.12.003
BibTeX
@article{Wang2026,
author = {Wang, Yantong and Sharma, Varun and Vu, Tony and Marasco, Silvana F},
title = {Effects of Transradial Catheterisation on Radial Artery Bypass Graft Patency: A Systematic Review and Meta-Analysis},
journal = {Heart, Lung and Circulation},
year = {2026},
doi = {10.1016/j.hlc.2025.12.003}
}
EUVIMED