EUVIMEDEUVIMED entdecken
Crossref

Optimal Conduit Diameter Selection in Coronary Bypass Grafting Using Saphenous Vein

Malgorzata Maggie Szpytma, Robert A Baker, Damian Gimpel, Richard F Newland, David G Lance, Gregory D Rice, Gareth Crouch, Jayme S Bennetts

Heart, Lung and Circulation · 2024

DOI: 10.1016/j.hlc.2024.01.035 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Heart, Lung and Circulation, 2024. Verfasst von Malgorzata Maggie Szpytma und 7 weiteren Autor:innen. Beteiligte Einrichtung: Cardiothoracic Surgery, Division of Surgery & Perioperative Medicine, Flinders Medical Centre, Adelaide, SA, Australia. Hauptthemen laut MEDLINE: Saphenous Vein, Coronary Artery Bypass, Coronary Artery Disease, Vascular Patency. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 47 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Predictors of long-term saphenous vein graft (SVG) patency following coronary artery bypass grafting (CABG) include harvesting technique, degree of proximal coronary stenosis, and target vessel diameter and runoff. The objective of this study was to evaluate the association between vein graft diameter and long-term survival. METHODS: Patients undergoing primary CABG (2000-2017) at Flinders Medical Centre, Adelaide, Australia, were categorised into three groups according to average SVG diameter ( 4 mm [large]). Survival data was obtained from the Australian Institute of Health and Welfare National Death Index. To determine the association of SVG diameter with long-term survival we used Kaplan-Meier survival analysis and Cox proportional hazard models adjusted for preoperative variables associated with survival. RESULTS: Vein graft diameter was collected in 3,797 patients. Median follow-up time was 7.6 years (interquartile range, 3.9-11.8) with 1,377 deaths. SVG size >4 mm was associated with lower rates of adjusted survival up to 4 years postoperatively (hazard ratio 1.48; 95% confidence interval 1.05-2.1; p=0.026). CONCLUSIONS: Vein graft diameter >4mm was found to be associated with lower rates of survival following CABG.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Saphenous VeinCoronary Artery BypassCoronary Artery DiseaseVascular PatencyHumansMaleFemaleAgedRetrospective StudiesMiddle AgedFollow-Up StudiesSurvival RateAustralia

Stichwörter der Autor:innen

BypassConduitCoronaryDiameterSaphenous vein

Autor:innen und Institutionen

  • Cardiothoracic Surgery, Division of Surgery & Perioperative Medicine, Flinders Medical Centre, Adelaide, SA, Australia.
  • Cardiothoracic Surgery, Division of Surgery & Perioperative Medicine, Flinders Medical Centre, Adelaide, SA, Australia; Perfusion and Cardiothoracic Surgery Quality and Outcomes Unit, Division of Surgery & Perioperative…
  • Cardiothoracic Surgery, Division of Surgery & Perioperative Medicine, Flinders Medical Centre, Adelaide, SA, Australia; Cardiothoracic Surgery, Department of Surgery, College of Medicine and Public Health, Flinders Univ…

Zitieren

APA

Szpytma, M. M., Baker, R. A., Gimpel, D., Newland, R. F., Lance, D. G., Rice, G. D., Crouch, G., & Bennetts, J. S. (2024). Optimal Conduit Diameter Selection in Coronary Bypass Grafting Using Saphenous Vein. Heart, Lung and Circulation. https://doi.org/10.1016/j.hlc.2024.01.035

Vancouver

Szpytma MM, Baker RA, Gimpel D, Newland RF, Lance DG, Rice GD, et al. Optimal Conduit Diameter Selection in Coronary Bypass Grafting Using Saphenous Vein. Heart, Lung and Circulation. 2024. doi:10.1016/j.hlc.2024.01.035

BibTeX
@article{Szpytma2024,
  author = {Szpytma, Malgorzata Maggie and Baker, Robert A and Gimpel, Damian and Newland, Richard F and Lance, David G and Rice, Gregory D and Crouch, Gareth and Bennetts, Jayme S},
  title = {Optimal Conduit Diameter Selection in Coronary Bypass Grafting Using Saphenous Vein},
  journal = {Heart, Lung and Circulation},
  year = {2024},
  doi = {10.1016/j.hlc.2024.01.035}
}
Kostenlos starten →