EUVIMEDEUVIMED entdecken
Crossref

Propensity score matching analysis for clinical impact of braided-type versus laser-cut-type covered self-expandable metal stents for endoscopic ultrasound-guided hepaticogastrostomy

Mitsuki Tomita, Takeshi Ogura, Akitoshi Hakoda, Saori Ueno, Atsushi Okuda, Nobu Nishioka, Yoshitaro Yamamoto, Hiroki Nishikawa

Hepatobiliary & Pancreatic Diseases International · 2024

DOI: 10.1016/j.hbpd.2023.08.006 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Hepatobiliary & Pancreatic Diseases International, 2024. Verfasst von Mitsuki Tomita und 7 weiteren Autor:innen. Beteiligte Einrichtung: 2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Osaka, Japan. Hauptthemen laut MEDLINE: Liver, Cholestasis. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 18 Literaturangaben. Gefördert von: Institut Ruđer Bošković.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: To prevent stent migration during endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS), intra-scope channel release technique is important, but is unfamiliar to non-expert hands. The self-expandable metal stent (SEMS) is an additional factor to prevent stent migration. However, no comparative studies of laser-cut-type and braided-type during EUS-HGS have been reported. The aim of this study was to compare the distance between the intrahepatic bile duct and stomach wall after EUS-HGS among laser-cut-type and braided-type SEMS. METHODS: To evaluate stent anchoring function, we measured the distance between the hepatic parenchyma and stomach wall before EUS-HGS, one day after EUS-HGS, and 7 days after EUS-HGS. Also, propensity score matching was performed to create a propensity score for using laser-cut-type group and braided-type group. RESULTS: A total of 142 patients were enrolled in this study. Among them, 24 patients underwent EUS-HGS using a laser-cut-type SEMS, and 118 patients underwent EUS-HGS using a braided-type SEMS. EUS-HGS using the laser-cut-type SEMS was mainly performed by non-expert endoscopists (n = 21); EUS-HGS using braided-type SEMS was mainly performed by expert endoscopists (n = 98). The distance after 1 day was significantly shorter in the laser-cut-type group than that in the braided-type group [2.00 (1.70-3.75) vs. 6.90 (3.72-11.70) mm, P < 0.001]. In addition, this distance remained significantly shorter in the laser-cut-type group after 7 days. Although these results were similar after propensity score matching analysis, the distance between hepatic parenchyma and stomach after 7 days was increased by 4 mm compared with the distance after 1 day in the braided-type group. On the other hand, in the laser-cut-type group, the distance after 1 day and 7 days was almost the same. CONCLUSIONS: EUS-HGS using a laser-cut-type SEMS may be safe to prevent stent migration, even in non-expert hands.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LiverCholestasisHumansPropensity ScoreEndosonographyStentsUltrasonography, InterventionalDrainage

Stichwörter der Autor:innen

Endoscopic retrograde cholangiopancreatographyEndoscopic ultrasound-guided biliary drainageEndoscopic ultrasound-guided hepaticogastrostomy

Autor:innen und Institutionen

  • 2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Osaka, Japan.
  • 2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Osaka, Japan; Endoscopy Center, Osaka Medical and Pharmaceutical University, Osaka, Japan. Electronic address: takeshi.ogura@ompu.ac.jp.
  • Endoscopy Center, Osaka Medical and Pharmaceutical University, Osaka, Japan.

Förderung

  • Institut Ruđer Bošković

Zitieren

APA

Tomita, M., Ogura, T., Hakoda, A., Ueno, S., Okuda, A., Nishioka, N., Yamamoto, Y., & Nishikawa, H. (2024). Propensity score matching analysis for clinical impact of braided-type versus laser-cut-type covered self-expandable metal stents for endoscopic ultrasound-guided hepaticogastrostomy. Hepatobiliary & Pancreatic Diseases International. https://doi.org/10.1016/j.hbpd.2023.08.006

Vancouver

Tomita M, Ogura T, Hakoda A, Ueno S, Okuda A, Nishioka N, et al. Propensity score matching analysis for clinical impact of braided-type versus laser-cut-type covered self-expandable metal stents for endoscopic ultrasound-guided hepaticogastrostomy. Hepatobiliary & Pancreatic Diseases International. 2024. doi:10.1016/j.hbpd.2023.08.006

BibTeX
@article{Tomita2024,
  author = {Tomita, Mitsuki and Ogura, Takeshi and Hakoda, Akitoshi and Ueno, Saori and Okuda, Atsushi and Nishioka, Nobu and Yamamoto, Yoshitaro and Nishikawa, Hiroki},
  title = {Propensity score matching analysis for clinical impact of braided-type versus laser-cut-type covered self-expandable metal stents for endoscopic ultrasound-guided hepaticogastrostomy},
  journal = {Hepatobiliary & Pancreatic Diseases International},
  year = {2024},
  doi = {10.1016/j.hbpd.2023.08.006}
}
Kostenlos starten →