Shoulder brace has no detrimental effect on basic spatio-temporal gait parameters and functional mobility after arthroscopic rotator cuff repair
Gait & Posture · 2024-01 · 107 · 207-211
DOI: 10.1016/j.gaitpost.2023.10.005 ↗Kurz gefasst
Fachartikel in der Zeitschrift Gait & Posture, 2024-01. Verfasst von Filippo Familiari und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic and Trauma Surgery, "Magna Græcia" University, Mater Domini" University Hospital, Catanzaro, Italy. Hauptthemen laut MEDLINE: Shoulder, Rotator Cuff Injuries. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Themen: Mobilisation
Abstract (Originalsprache)
BACKGROUND: The risk of falls in patients undergoing orthopedic procedures is significant in terms of health and socioeconomic effects. RESEARCH QUESTION: Is there an influence of the shoulder abduction brace (SAB) on gait parameters in patients undergoing arthroscopic rotator cuff repair (ARCR)? METHODS: Thirty-five patients undergoing ARCR, who used a 15° SAB in the postoperative period, were included in a prospective study. Participants underwent gait analysis preoperatively (T0), 24 h after surgery (T1), 1 week (T2), and 4 weeks after surgery (1 week after SAB removal) (T3) by using a wearable inertial sensor (BTS G-Walk sensor). Gait Parameters (cadence, speed, right (R) and left (L) step length, gait and propulsion-R and L symmetry indices) and functional mobility (agility and balance) were assessed using the 10-meter test (10MWT) and the Timed Up and Go (TUG) test, respectively. RESULTS: There were 22 men and 13 women with a median age of 56 (IQR 48.0-61.0) years. The right upper limb was involved in 83% of cases. Regarding the 10MWT, speed was significantly higher at T0 than at T1 (p 0.05). Regarding TUG test, the final turning phase was significantly higher at T2 than at T3 (p < 0.01). SIGNIFICANCE: The results demonstrated that the use of the SAB affected gait speed and propulsion only 24 h after ARCR, but no effects were reported at long-term observations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic and Trauma Surgery, "Magna Græcia" University, Mater Domini" University Hospital, Catanzaro, Italy.
- Department of Orthopaedic and Trauma Surgery, "Magna Græcia" University, Mater Domini" University Hospital, Catanzaro, Italy. Electronic address: mercuriomi@gmail.com.
- Department of Orthopaedic and Trauma Surgery, Clínica Universidad de Navarra, Madrid, Spain.
- Department of Movement, Human and Health Sciences, University of Rome "Foro Italico", Rome, Italy.
- Department of Experimental and Clinical Medicine, "Magna Grecia" University, Catanzaro, Italy.
Zitieren
APA
Familiari, F., Mercurio, M., Arenas-Miquelez, A., Barone, A., Greco, F., Emerenziani, G. P., Gasparini, G., & Galasso, O. (2024). Shoulder brace has no detrimental effect on basic spatio-temporal gait parameters and functional mobility after arthroscopic rotator cuff repair. Gait & Posture, 107, 207-211. https://doi.org/10.1016/j.gaitpost.2023.10.005
Vancouver
Familiari F, Mercurio M, Arenas-Miquelez A, Barone A, Greco F, Emerenziani GP, et al. Shoulder brace has no detrimental effect on basic spatio-temporal gait parameters and functional mobility after arthroscopic rotator cuff repair. Gait & Posture. 2024;107:207-211. doi:10.1016/j.gaitpost.2023.10.005
BibTeX
@article{Familiari2024,
author = {Familiari, Filippo and Mercurio, Michele and Arenas-Miquelez, Antonio and Barone, Alessandro and Greco, Francesca and Emerenziani, Gian Pietro and Gasparini, Giorgio and Galasso, Olimpio},
title = {Shoulder brace has no detrimental effect on basic spatio-temporal gait parameters and functional mobility after arthroscopic rotator cuff repair},
journal = {Gait & Posture},
year = {2024},
volume = {107},
pages = {207--211},
doi = {10.1016/j.gaitpost.2023.10.005}
}
EUVIMED