SiMSen-Seq STR sequencing across five laboratories enables lowered noise thresholds and improved allele calling
Forensic Science International: Genetics · 2027
DOI: 10.1016/j.fsigen.2026.103548 ↗Kurz gefasst
Fachartikel in der Zeitschrift Forensic Science International: Genetics, 2027. Verfasst von Arvid H Gynnå und 13 weiteren Autor:innen. Beteiligte Einrichtung: National Forensic Centre, Swedish Police Authority, Linköping SE-581 94, Sweden. Hauptthemen laut MEDLINE: Microsatellite Repeats, Alleles, Sequence Analysis, DNA, Laboratories. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Swedish Research Council, Sweden's Innovation Agency, Vastra Gotaland Region.
Abstract (Originalsprache)
Unique molecular identifiers (UMI) can be used in forensic STR sequencing to reduce the level of analytical artifacts. Here, we perform an interlaboratory study across five independent sites where the previously developed UMI-based SiMSen-Seq STR assay is applied at each laboratory to both single-source and mixed samples. The assay showed consistent results between laboratories and more than 90% of the expected alleles were detected with 31 pg DNA of template. The assay tolerated ten times higher PCR inhibitor concentrations compared to an established commercial STR sequencing method. The combined results were used to determine stutter and noise thresholds, which were applied for allele calling, allowing an estimation of the sensitivity for minor contributor alleles in mixtures. We found that the SiMSen-Seq STR method is robust across laboratories and different types of PCR and sequencing equipment and that it allows for calling of alleles from contributors of smaller proportions compared to currently commercially available non-UMI STR sequencing methods.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- National Forensic Centre, Swedish Police Authority, Linköping SE-581 94, Sweden.
- National Institute of Standards and Technology, 100 Bureau Drive, M/S 8314, Gaithersburg, MD 20899, USA.
- Department of Forensic Genetics and Forensic Toxicology, National Board of Forensic Medicine, Linköping SE-587 58, Sweden; Department of Biomedical and Clinical Sciences, Faculty of Health Sciences, Linköping University…
- RISE Research Institutes of Sweden, Methodology, Textile and Medical Device Technology, Brinellgatan 4, Borås 504 62, Sweden.
- Department of Laboratory Medicine, Sahlgrenska Center for Cancer Research, Institute of Biomedicine, Sahlgrenska Academy, University of Gothenburg, Medicinaregatan 1F, Gothenburg 41390, Sweden.
- RISE Research Institutes of Sweden, Methodology, Textile and Medical Device Technology, Brinellgatan 4, Borås 504 62, Sweden; Department of Laboratory Medicine, Institute of Biomedicine, University of Gothenburg, Sahlgr…
Förderung
- Swedish Research Council
- Sweden's Innovation Agency
- Vastra Gotaland Region
- Swedish Agency for Economic and Regional Growth
Zitieren
APA
Gynnå, A. H., Sidstedt, M., Kiesler, K. M., Staadig, A., Lindgren, Å., Kebede, F. T., Håkansson, J., Steffen, C. R., Österlund, T., Bogestål, Y., Tillmar, A., Vallone, P. M., Ståhlberg, A., & Hedman, J. (2027). SiMSen-Seq STR sequencing across five laboratories enables lowered noise thresholds and improved allele calling. Forensic Science International: Genetics. https://doi.org/10.1016/j.fsigen.2026.103548
Vancouver
Gynnå AH, Sidstedt M, Kiesler KM, Staadig A, Lindgren Å, Kebede FT, et al. SiMSen-Seq STR sequencing across five laboratories enables lowered noise thresholds and improved allele calling. Forensic Science International: Genetics. 2027. doi:10.1016/j.fsigen.2026.103548
BibTeX
@article{Gynn2027,
author = {Gynnå, Arvid H and Sidstedt, Maja and Kiesler, Kevin M and Staadig, Adam and Lindgren, Åsa and Kebede, Firaol Tamiru and Håkansson, Joakim and Steffen, Carolyn R and Österlund, Tobias and Bogestål, Yalda and Tillmar, Andreas and Vallone, Peter M and Ståhlberg, Anders and Hedman, Johannes},
title = {SiMSen-Seq STR sequencing across five laboratories enables lowered noise thresholds and improved allele calling},
journal = {Forensic Science International: Genetics},
year = {2027},
doi = {10.1016/j.fsigen.2026.103548}
}
EUVIMED