EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Evidence-based evaluation of the analytical schemes in ASTM E2329-17 Standard Practice for Identification of Seized Drugs for methamphetamine samples

Jeremy S. Triplett, Jeff Salyards, Sandra E. Rodriguez-Cruz, Jeremiah A. Morris, Darryl Creel, Joseph Zemmels, Megan Grabenauer

Forensic Chemistry · 2024-05 · 38 · 100560

DOI: 10.1016/j.forc.2024.100560 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Forensic Chemistry, 2024-05. Verfasst von Jeremy S. Triplett und 6 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: U.S. Department of Justice, Office of Justice Programs, National Institute of Justice.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study involved 71 forensic seized drug laboratories analyzing 65 total samples; 17 were ground-truth positive (i.e., they contained methamphetamine or cocaine); 48 were ground-truth negative (i.e., they did not contain methamphetamine or cocaine). The positive samples were prepared at several target-analyte concentrations and combined with common cutting agents. The negative samples were designed to be challenging and prepared to contain positional isomers of methamphetamine. Participants were sent two different sample sets. In the first, they were directed to only use a single, pre-selected analytical technique. In the second, they were directed to use a pre-selected analytical scheme consisting of multiple techniques in compliance with ASTM E2329-17. The results of the study showed good accuracy; sensitivity was 1.000 for all analytical schemes with 1-specificity (the false-positive rate) ranging from 0.000 to 0.250 when ASTM E2329-17 compliant analytical schemes were used. When only a single technique was used, accuracy was generally not as good; sensitivity ranged from 1.000 to 0.091, and 1-specificity ranged from 0.000 to 0.245.

Förderung

  • U.S. Department of Justice
  • Office of Justice Programs
  • National Institute of Justice

Zitieren

APA

Triplett, J. S., Salyards, J., Rodriguez-Cruz, S. E., Morris, J. A., Creel, D., Zemmels, J., & Grabenauer, M. (2024). Evidence-based evaluation of the analytical schemes in ASTM E2329-17 Standard Practice for Identification of Seized Drugs for methamphetamine samples. Forensic Chemistry, 38, 100560. https://doi.org/10.1016/j.forc.2024.100560

Vancouver

Triplett JS, Salyards J, Rodriguez-Cruz SE, Morris JA, Creel D, Zemmels J, et al. Evidence-based evaluation of the analytical schemes in ASTM E2329-17 Standard Practice for Identification of Seized Drugs for methamphetamine samples. Forensic Chemistry. 2024;38:100560. doi:10.1016/j.forc.2024.100560

BibTeX
@article{Triplett2024,
  author = {Triplett, Jeremy S. and Salyards, Jeff and Rodriguez-Cruz, Sandra E. and Morris, Jeremiah A. and Creel, Darryl and Zemmels, Joseph and Grabenauer, Megan},
  title = {Evidence-based evaluation of the analytical schemes in ASTM E2329-17 Standard Practice for Identification of Seized Drugs for methamphetamine samples},
  journal = {Forensic Chemistry},
  year = {2024},
  volume = {38},
  pages = {100560},
  doi = {10.1016/j.forc.2024.100560}
}
Kostenlos starten →