EUVIMEDEUVIMED entdecken
Evaluationsstudie

Rapid and visual detection of Listeria monocytogenes by combining one-pot LAMP–CRISPR/Cas12b with lateral flow assay

Xuelan Liu, Yuting Zheng, Zhiwei Chen, Shiqi Wang, Hongyan Liao, Jianye Jia, Guijun Wang, Jialing Wang, Chunyan Yuan, Xiaoxi Guo, Yuelan Yin, Qinghai Hu

Food Microbiology · 2026-04 · 135 · 104977

DOI: 10.1016/j.fm.2025.104977 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Food Microbiology, 2026-04. Verfasst von Xuelan Liu und 11 weiteren Autor:innen. Beteiligte Einrichtung: College of Veterinary Medicine, Anhui Agricultural University, 130 West Changjiang Road, Hefei, 230036, China. Hauptthemen laut MEDLINE: Listeria monocytogenes, Nucleic Acid Amplification Techniques, CRISPR-Cas Systems, Molecular Diagnostic Techniques. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 44 Literaturangaben. Gefördert von: Science and Technology Innovation Plan Of Shanghai Science and Technology Commission.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Listeria monocytogenes, the leading cause of fatalities worldwide among foodborne pathogens, poses serious risks to food safety and public health. Therefore, a rapid and accurate detection method is crucial for early interception and effective management. In this study, a one-pot LAMP-CRISPR/Cas12b detection system based on the lmo0753 gene was developed for rapid detection of L. monocytogenes by combining loop-mediated isothermal amplification (LAMP) with a CRISPR/Cas12b assay. Further integration of a lateral flow assay (LFA) to develop a LAMP-CRISPR/Cas12b-LFA assay enabled direct detection of the results on the strips with the naked eye. Nine L. monocytogenes strains belonging to eight serotypes tested positive with both the one-pot LAMP-CRISPR/Cas12b and LAMP-CRISPR/Cas12b-LFA assays. Two assays did not show cross-reactivity with L. innocua and eight other foodborne bacteria. The limits of detection were 10 CFU/mL for pure culture and 20 CFU/g for spiked pork samples. Moreover, the enrichment time was substantially shortened to 3 h for pork samples spiked with only L. monocytogenes F2365, and 4-5 h for pork samples spiked with mixed bacteria. In addition, with one-pot LAMP-CRISPR/Cas12b detection, 5 of 66 fresh pork samples, 1 of 20 ready-to-eat food samples, and 2 of 24 raw milk samples tested positive for L. monocytogenes, in agreement with the results obtained through a culture based standard method. Thus, this study established one-pot LAMP-CRISPR/Cas12b and LAMP-CRISPR/Cas12b-LFA assays for rapid, visual detection of L. monocytogenes in food samples.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Listeria monocytogenesNucleic Acid Amplification TechniquesCRISPR-Cas SystemsMolecular Diagnostic TechniquesAnimalsFood ContaminationFood MicrobiologySwineSensitivity and SpecificityLimit of Detection

Stichwörter der Autor:innen

CRISPR/Cas12bLAMPLateral flow assayLimit of detectionListeria monocytogenes

Autor:innen und Institutionen

  • College of Veterinary Medicine, Anhui Agricultural University, 130 West Changjiang Road, Hefei, 230036, China.
  • College of Veterinary Medicine, Anhui Agricultural University, 130 West Changjiang Road, Hefei, 230036, China; Shanghai Veterinary Research Institute, Chinese Academy of Agricultural Sciences, 518 Ziyue Road, Shanghai,…
  • Shanghai Veterinary Research Institute, Chinese Academy of Agricultural Sciences, 518 Ziyue Road, Shanghai, 200241, China.
  • Key Laboratory of Zoonoses of Jiangsu Province, Yangzhou University, Yangzhou, 225009, China.
  • Key Laboratory of Zoonoses of Jiangsu Province, Yangzhou University, Yangzhou, 225009, China. Electronic address: yylan@yzu.edu.cn.
  • Shanghai Veterinary Research Institute, Chinese Academy of Agricultural Sciences, 518 Ziyue Road, Shanghai, 200241, China. Electronic address: huqinghai@caas.cn.

Förderung

  • Science and Technology Innovation Plan Of Shanghai Science and Technology Commission

Zitieren

APA

Liu, X., Zheng, Y., Chen, Z., Wang, S., Liao, H., Jia, J., Wang, G., Wang, J., Yuan, C., Guo, X., Yin, Y., & Hu, Q. (2026). Rapid and visual detection of Listeria monocytogenes by combining one-pot LAMP–CRISPR/Cas12b with lateral flow assay. Food Microbiology, 135, 104977. https://doi.org/10.1016/j.fm.2025.104977

Vancouver

Liu X, Zheng Y, Chen Z, Wang S, Liao H, Jia J, et al. Rapid and visual detection of Listeria monocytogenes by combining one-pot LAMP–CRISPR/Cas12b with lateral flow assay. Food Microbiology. 2026;135:104977. doi:10.1016/j.fm.2025.104977

BibTeX
@article{Liu2026,
  author = {Liu, Xuelan and Zheng, Yuting and Chen, Zhiwei and Wang, Shiqi and Liao, Hongyan and Jia, Jianye and Wang, Guijun and Wang, Jialing and Yuan, Chunyan and Guo, Xiaoxi and Yin, Yuelan and Hu, Qinghai},
  title = {Rapid and visual detection of Listeria monocytogenes by combining one-pot LAMP–CRISPR/Cas12b with lateral flow assay},
  journal = {Food Microbiology},
  year = {2026},
  volume = {135},
  pages = {104977},
  doi = {10.1016/j.fm.2025.104977}
}
Kostenlos starten →