Large-scale compartment fires to develop a self-extinction design framework for mass timber-Part 2: Results, analysis and design implications
Fire Safety Journal · 2025-05 · 152 · 104346
DOI: 10.1016/j.firesaf.2025.104346 ↗Kurz gefasst
Fachartikel in der Zeitschrift Fire Safety Journal, 2025-05. Verfasst von Felix Wiesner und 6 weiteren Autor:innen. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Australian Research Council.
Abstract (Originalsprache)
This paper seeks to provide key fundamental knowledge underpinning the use of self-extinction principles as part of a design framework for buildings with engineered mass timber structures. The results from six compartment fire experiments in a cross-laminated timber (CLT) enclosure with different ratios of exposed timber are presented and analyzed to establish the effects of timber exposure on the dynamics of a fire and on the potential of the fire to self-extinguish. The results show the relevance of four key parameters that need to be considered concurrently when assessing self-extinction in mass timber compartments: (a) the characteristic time for burnout of the movable fuel load, (b) the characteristic time for the occurrence of char fall-off, (c) the characteristic time for the occurrence of encapsulation failure, and (d) the heat exchange within the compartment after consumption of the moveable fuel. Self-extinction was attained only when the characteristic time for the occurrence of char fall-off was longer than the characteristic time for burn-out and the heat exchange after burn-out resulted in a heat flux below a well-defined threshold. The position of the exposed timber surfaces affected the magnitude of the threshold heat flux. If the characteristic time for burn-out was greater than the characteristic time for encapsulation failure, self-extinction was not observed to occur.
Förderung
- Australian Research Council
Zitieren
APA
Wiesner, F., Xu, H., Lange, D., Gupta, V., Pope, I., Torero, J. L., & Hidalgo, J. P. (2025). Large-scale compartment fires to develop a self-extinction design framework for mass timber-Part 2: Results, analysis and design implications. Fire Safety Journal, 152, 104346. https://doi.org/10.1016/j.firesaf.2025.104346
Vancouver
Wiesner F, Xu H, Lange D, Gupta V, Pope I, Torero JL, et al. Large-scale compartment fires to develop a self-extinction design framework for mass timber-Part 2: Results, analysis and design implications. Fire Safety Journal. 2025;152:104346. doi:10.1016/j.firesaf.2025.104346
BibTeX
@article{Wiesner2025,
author = {Wiesner, Felix and Xu, Hangyu and Lange, David and Gupta, Vinny and Pope, Ian and Torero, José L. and Hidalgo, Juan P.},
title = {Large-scale compartment fires to develop a self-extinction design framework for mass timber-Part 2: Results, analysis and design implications},
journal = {Fire Safety Journal},
year = {2025},
volume = {152},
pages = {104346},
doi = {10.1016/j.firesaf.2025.104346}
}
EUVIMED