EUVIMEDEUVIMED entdecken
Crossref

Simultaneous biomonitoring of common food carcinogen acrylamide and its major metabolites using fast urinary metabolites extraction technique coupled with LC-MS/MS analysis

Pei-Chien Tsai, Karthikeyan Prakasham, Swapnil Gurrani, Shih-Tao Hu, Po-Chin Huang, Jentaie Shiea, Vimalkumar Krishnamoorthi, Ming-Tsang Wu, Chia-Fang Wu, Vinoth Kumar Ponnusamy

Food and Chemical Toxicology · 2025

DOI: 10.1016/j.fct.2025.115606 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Food and Chemical Toxicology, 2025. Verfasst von Pei-Chien Tsai und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicinal and Applied Chemistry, Kaohsiung Medical University (KMU), Kaohsiung City, 807, Taiwan; Department of Computational Biology, …. Hauptthemen laut MEDLINE: Acrylamide, Tandem Mass Spectrometry, Carcinogens, Biological Monitoring. Die Arbeit nennt 30 Literaturangaben. Gefördert von: Kaohsiung Medical University, Ministry of Education, National Health Research Institutes.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Acrylamide (AA) is a probable carcinogen, often found in the environment and food, which causes various cancers in humans. Therefore, it is vital to have a facile, quick, sensitive analytical method for biomonitoring AA and its metabolites (including glycidamide (GA), N-acetyl-S-(2-carbamoylethyl)-l-cysteine (AAMA), N-acetyl-S-(2-carbamoyl-2-hydroxyethyl)-l-cysteine (GAMA)) in human urine sample for exposure risk and toxicology assessment applications. In this study, we presented a rapid sample pre-treatment technique named "fast urinary metabolites extraction technique" (FaUMEx) coupled with UHPLC-MS/MS method for efficient biomonitoring of AA and its metabolites in human urine samples. In the FaUMEx technique, two syringes were integrated for liquid-liquid extraction, followed by a micro-solid phase clean-up process. The fully optimized and validated FaUMEx/UHPLC-MS/MS technique yielded good detection and quantification levels (LOD of 0.01-0.2 ng/mL, and LOQ of 0.5-0.05 ng/mL for AA, GA, AAMA, and GAMA, respectively). The inter- and intra-day analysis shows reliable relative recoveries ranging from 82.9 to 116.8 % with

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AcrylamideTandem Mass SpectrometryCarcinogensBiological MonitoringHumansChromatography, High Pressure LiquidFood ContaminationLimit of DetectionEpoxy CompoundsLiquid Chromatography-Mass Spectrometry

Stichwörter der Autor:innen

Acrylamide and its metabolitesBiomonitoringHuman urineIn-syringe based fast urinary metabolites extraction techniqueUHPLC-MS/MS

Substanzen

AcrylamideCarcinogensEpoxy Compoundsglycidamide

Autor:innen und Institutionen

  • Department of Medicinal and Applied Chemistry, Kaohsiung Medical University (KMU), Kaohsiung City, 807, Taiwan; Department of Computational Biology, Institute of Bioinformatics, Saveetha School of Engineering, Saveetha…
  • Research Center for Precision Environmental Medicine, Kaohsiung Medical University (KMU), Kaohsiung City, 807, Taiwan.
  • Department of Applied Sciences and Humanities, Invertis University, Bareilly, Uttar Pradesh, 243122, India.
  • Department of Medicinal and Applied Chemistry, Kaohsiung Medical University (KMU), Kaohsiung City, 807, Taiwan.
  • Research Center for Precision Environmental Medicine, Kaohsiung Medical University (KMU), Kaohsiung City, 807, Taiwan; National Institute of Environmental Health Sciences, National Health Research Institutes (NHRI), Mia…
  • Department of Medicinal and Applied Chemistry, Kaohsiung Medical University (KMU), Kaohsiung City, 807, Taiwan; Research Center for Precision Environmental Medicine, Kaohsiung Medical University (KMU), Kaohsiung City, 8…

Förderung

  • Kaohsiung Medical University
  • Ministry of Education
  • National Health Research Institutes
  • National Science and Technology Council

Zitieren

APA

Tsai, P. C., Prakasham, K., Gurrani, S., Hu, S. T., Huang, P. C., Shiea, J., Krishnamoorthi, V., Wu, M. T., Wu, C. F., & Ponnusamy, V. K. (2025). Simultaneous biomonitoring of common food carcinogen acrylamide and its major metabolites using fast urinary metabolites extraction technique coupled with LC-MS/MS analysis. Food and Chemical Toxicology. https://doi.org/10.1016/j.fct.2025.115606

Vancouver

Tsai PC, Prakasham K, Gurrani S, Hu ST, Huang PC, Shiea J, et al. Simultaneous biomonitoring of common food carcinogen acrylamide and its major metabolites using fast urinary metabolites extraction technique coupled with LC-MS/MS analysis. Food and Chemical Toxicology. 2025. doi:10.1016/j.fct.2025.115606

BibTeX
@article{Tsai2025,
  author = {Tsai, Pei-Chien and Prakasham, Karthikeyan and Gurrani, Swapnil and Hu, Shih-Tao and Huang, Po-Chin and Shiea, Jentaie and Krishnamoorthi, Vimalkumar and Wu, Ming-Tsang and Wu, Chia-Fang and Ponnusamy, Vinoth Kumar},
  title = {Simultaneous biomonitoring of common food carcinogen acrylamide and its major metabolites using fast urinary metabolites extraction technique coupled with LC-MS/MS analysis},
  journal = {Food and Chemical Toxicology},
  year = {2025},
  doi = {10.1016/j.fct.2025.115606}
}
Kostenlos starten →