EUVIMEDEUVIMED entdecken
Crossref

GC-MS and HPLC-FLD for sensitive assay of toxic cyclohexylamine in artificial sweetener tablets and human biological fluids

Hazim M Ali, Amr A Essawy, Ahmed Hamad Alanazi, Arafa Musa, Ahmed Emad F Abbas, Ibrahim Bayoumi Abdel-Farid, Mohammed Gamal

Food and Chemical Toxicology · 2025

DOI: 10.1016/j.fct.2025.115447 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Food and Chemical Toxicology, 2025. Verfasst von Hazim M Ali und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, College of Science, Jouf University, P.O. Box 2014, Sakaka, Aljouf, Saudi Arabia. Electronic address: hmali@ju.edu.sa. Hauptthemen laut MEDLINE: Gas Chromatography-Mass Spectrometry, Sweetening Agents. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: Jouf University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cyclohexylamine (CHA) is a precursor in the synthesis of artificial sweeteners cyclamate and its major metabolite. CHA is toxic to the nervous system, kidneys, and liver in animal studies. In the present work, gas chromatography-mass spectrometry (GC-MS) and high-performance liquid chromatography-fluorescence detection (HPLC-FLD) were introduced for the first time to the determination of nano-level concentration of CHA in artificial sweetener tablets and human biological fluids. According to the obtained results, HPLC-FLD and GC-MS of CHA exhibit a wide linear range from 1 to 1250 ng/mL and 5-1500 ng/mL within limits of detection of 0.49 and 1.55 ng/mL, respectively. Furthermore, both chromatographic techniques exhibited high accuracy and precision, yielding recovery estimates ranging from 95.85 % to 100.70 % for the HPLC-FLD method and 91.54 %-99.64 % for the other while the corresponding values of relative standard deviation (RSD%) range from 0.25 to 0.82 % and 1.25-3.97 %. The accuracies for HPLC-FLD and GC-MS method in serum and urine samples are within the range of 90.29-99.94 %. On the other hand, CHA was detected in all studied artificial sweetener tablets, its level ranged from 1.35 to 102.64 ng/tablet. Also, the results obtained from the HPLC-FLD and GC-MS methods were statistically compared, and no significant difference was found.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Gas Chromatography-Mass SpectrometrySweetening AgentsHumansChromatography, High Pressure LiquidTabletsLimit of DetectionSpectrometry, FluorescenceReproducibility of Results

Stichwörter der Autor:innen

Artificial sweetener tabletsCyclamateCyclohexylamineGC-MSHPLC-FLD

Substanzen

TabletsSweetening Agents

Autor:innen und Institutionen

  • Department of Chemistry, College of Science, Jouf University, P.O. Box 2014, Sakaka, Aljouf, Saudi Arabia. Electronic address: hmali@ju.edu.sa.
  • Department of Chemistry, College of Science, Jouf University, P.O. Box 2014, Sakaka, Aljouf, Saudi Arabia.
  • Department of Pharmacognosy, College of Pharmacy, Jouf University, Sakaka, Aljouf, 72341, Saudi Arabia.
  • Faculty of Pharmacy, Analytical Chemistry Department, October 6 University, 6 October City, 12585, Giza, Egypt.
  • Department of Botany, Faculty of Science, Aswan University, Aswan, 81528, Egypt.
  • Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Beni-Suef University, Alshaheed Shehata Ahmed Hegazy St., 62574, Beni-Suef, Egypt.

Förderung

  • Jouf University

Zitieren

APA

Ali, H. M., Essawy, A. A., Alanazi, A. H., Musa, A., Abbas, A. E. F., Abdel-Farid, I. B., & Gamal, M. (2025). GC-MS and HPLC-FLD for sensitive assay of toxic cyclohexylamine in artificial sweetener tablets and human biological fluids. Food and Chemical Toxicology. https://doi.org/10.1016/j.fct.2025.115447

Vancouver

Ali HM, Essawy AA, Alanazi AH, Musa A, Abbas AEF, Abdel-Farid IB, et al. GC-MS and HPLC-FLD for sensitive assay of toxic cyclohexylamine in artificial sweetener tablets and human biological fluids. Food and Chemical Toxicology. 2025. doi:10.1016/j.fct.2025.115447

BibTeX
@article{Ali2025,
  author = {Ali, Hazim M and Essawy, Amr A and Alanazi, Ahmed Hamad and Musa, Arafa and Abbas, Ahmed Emad F and Abdel-Farid, Ibrahim Bayoumi and Gamal, Mohammed},
  title = {GC-MS and HPLC-FLD for sensitive assay of toxic cyclohexylamine in artificial sweetener tablets and human biological fluids},
  journal = {Food and Chemical Toxicology},
  year = {2025},
  doi = {10.1016/j.fct.2025.115447}
}
Kostenlos starten →