EUVIMEDEUVIMED entdecken
Vergleichsstudie

IOFix™ with plate construct is similar to locking plate construct for Lapidus bunionectomy procedure outcomes

Amol Saxena, Todd O'Brien, Miranda Royds

Foot and Ankle Surgery · 2026

DOI: 10.1016/j.fas.2026.01.003 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Foot and Ankle Surgery, 2026. Verfasst von Amol Saxena und 2 weiteren Autor:innen. Beteiligte Einrichtung: BASS Medical Group, Palo Alto, CA, United States. Hauptthemen laut MEDLINE: Bone Plates, Hallux Valgus, Osteotomy. Die Arbeit nennt 20 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The Lapidus bunionectomy has evolved with advanced fixation constructs since its first description. These new techniques have aimed to reduce complications such as non-union or hardware related symptoms. The IOFix™ system, an intramedullary device that has been designed to enhance stability and compression, may offer outcomes that are comparable to traditional medial locking plate with lag screw constructs. PURPOSE: To compare outcomes of the Lapidus bunionectomy using the IOFix™ and plate construct versus a traditional medial locking plate with a plantar lag screw. METHODS: This IRB-approved retrospective case-control study reviewed 46 patients (23 per cohort) treated by a single surgeon between 2014 and 2022, with minimum 24-month follow-up. Patients underwent Lapidus bunionectomy using either an IOFix™ and dorsal plate (intervention) or a locking plate with plantar lag screw (control). Outcome measures included incidence of non-union, hardware removal, loss of correction (1st IMA >8° or HAA >20°), and AOFAS Hallux scores. Statistical analysis used two-tailed t-tests and Fisher's exact test with significance set at P < 0.05. RESULTS: All cases in both IOFix™ and locking plate groups achieved a union rate of 100 %. There were no reported infections, non-unions, or revision surgeries in either cohort. Hardware removal rates were not significantly different between IOFix™ (26 %) and control (13 %) groups (P = 0.46), and only the dorsal plates were removed. There were no reported cases of removal of the IOFix™ device. AOFAS scores improved significantly in both groups post-operatively (P < 0.0001), with no significant difference between groups pre- or post-operatively. There were no significant differences in demographic data, loss of correction, or complication rates between groups. CONCLUSION: The IOFix™ and dorsal plate construct offers comparable outcomes to traditional locking plate with lag screw fixation in the Lapidus bunionectomy, with similar union rates, clinical outcomes, and hardware-related complications. These findings suggest that IOFix™ is an effective alternative fixation method. Further studies with larger sample sizes and long-term follow-up are warranted.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bone PlatesHallux ValgusOsteotomyHumansRetrospective StudiesBone ScrewsFemaleHardware RemovalCase-Control StudiesMaleMiddle AgedTreatment OutcomeAgedAdult

Stichwörter der Autor:innen

Arthrodesis outcomesBunion surgeryClinical outcomesFirst tarsometatarsal arthrodesisFixation biomechanicsFoot and ankle surgeryFusion rateHallux valgus correctionIOFix™Internal fixationLapidus bunionectomyLocking plate constructPodiatric SurgeryRadiographic outcomes

Autor:innen und Institutionen

  • BASS Medical Group, Palo Alto, CA, United States.
  • Penobscot Valley Hospital, Lincoln, ME, United States; Department of Chemical and Biomedical Engineering, University of Maine, Orono, ME, United States.
  • Inova Fairfax Medical Campus, Falls Church, VA, United States. Electronic address: miranda.royds@inova.org.

Zitieren

APA

Saxena, A., O'Brien, T., & Royds, M. (2026). IOFix™ with plate construct is similar to locking plate construct for Lapidus bunionectomy procedure outcomes. Foot and Ankle Surgery. https://doi.org/10.1016/j.fas.2026.01.003

Vancouver

Saxena A, O'Brien T, Royds M. IOFix™ with plate construct is similar to locking plate construct for Lapidus bunionectomy procedure outcomes. Foot and Ankle Surgery. 2026. doi:10.1016/j.fas.2026.01.003

BibTeX
@article{Saxena2026,
  author = {Saxena, Amol and O'Brien, Todd and Royds, Miranda},
  title = {IOFix™ with plate construct is similar to locking plate construct for Lapidus bunionectomy procedure outcomes},
  journal = {Foot and Ankle Surgery},
  year = {2026},
  doi = {10.1016/j.fas.2026.01.003}
}
Kostenlos starten →