EUVIMEDEUVIMED entdecken
Vergleichsstudie

Cannulated screws versus nitinol staple for tarsometatarsal fusion: A cadaveric biomechanical comparison model

Temitope Adebayo, Zachary Koroneos, Erdi Özdemir, Alex Herrin, Sherif El Akkari, Gregory Lewis, Umur Aydogan

Foot and Ankle Surgery · 2024-12 · 30 (8) · 656-661

DOI: 10.1016/j.fas.2024.05.011 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Foot and Ankle Surgery, 2024-12. Verfasst von Temitope Adebayo und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics & Rehabilitation, Penn State Health, Milton S. Hershey Medical Center, Hershey, PA, USA. Hauptthemen laut MEDLINE: Alloys, Cadaver, Bone Screws, Arthrodesis. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 19 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The objective of this study was to evaluate the biomechanical stability of a medially placed nitinol staple compared to two crossed-screws in the first TMT-1 joint fusion in a cadaveric cyclic loading model. METHODS: Seven matched pairs (N = 7) of lower limb cadaveric specimens were utilized. TMT-1 joints from each donor were fixed with a medially placed nitinol staple or dorsally placed two 3.5 mm partially threaded cannulated crossed-screws. Specimens were tested in a 4-point bending setting with increasing cyclic forces. RESULTS: The mean plantar gapping was not significantly different between the two groups at any loading stage below 200 N. Specimens fixed with a nitinol staple failed at a mean load of 305 ± 57 N. Conversely, those fixed with crossed-screws failed at 373 ± 86 N. (P = .09). CONCLUSION: There was no statistical difference between a medially placed nitinol staple and dorsally placed crossed-screws in failure loads and plantar gapping under cyclic loads at the TMT-1 joint, however, the staple fixation was much more variable. LEVEL OF EVIDENCE: Level V, basic science study, biomechanics.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AlloysCadaverBone ScrewsArthrodesisHumansBiomechanical PhenomenaSuturesAgedMaleFemaleMetatarsal BonesMiddle Aged

Stichwörter der Autor:innen

BunionFixationHallux valgusLapidus procedureNitinol stapleScrewTarsometatarsal arthrodesis

Substanzen

nitinolAlloys

Autor:innen und Institutionen

  • Department of Orthopaedics & Rehabilitation, Penn State Health, Milton S. Hershey Medical Center, Hershey, PA, USA.
  • Department of Orthopaedics & Rehabilitation, Penn State Health, Milton S. Hershey Medical Center, Hershey, PA, USA. Electronic address: erdiozdemir@gmail.com.

Zitieren

APA

Adebayo, T., Koroneos, Z., Özdemir, E., Herrin, A., El Akkari, S., Lewis, G., & Aydogan, U. (2024). Cannulated screws versus nitinol staple for tarsometatarsal fusion: A cadaveric biomechanical comparison model. Foot and Ankle Surgery, 30(8), 656-661. https://doi.org/10.1016/j.fas.2024.05.011

Vancouver

Adebayo T, Koroneos Z, Özdemir E, Herrin A, El Akkari S, Lewis G, et al. Cannulated screws versus nitinol staple for tarsometatarsal fusion: A cadaveric biomechanical comparison model. Foot and Ankle Surgery. 2024;30(8):656-661. doi:10.1016/j.fas.2024.05.011

BibTeX
@article{Adebayo2024,
  author = {Adebayo, Temitope and Koroneos, Zachary and Özdemir, Erdi and Herrin, Alex and El Akkari, Sherif and Lewis, Gregory and Aydogan, Umur},
  title = {Cannulated screws versus nitinol staple for tarsometatarsal fusion: A cadaveric biomechanical comparison model},
  journal = {Foot and Ankle Surgery},
  year = {2024},
  volume = {30},
  number = {8},
  pages = {656--661},
  doi = {10.1016/j.fas.2024.05.011}
}
Kostenlos starten →