Early results of combined total ankle total talus replacement in the revision setting
Foot and Ankle Surgery · 2024
DOI: 10.1016/j.fas.2024.03.012 ↗Kurz gefasst
Fachartikel in der Zeitschrift Foot and Ankle Surgery, 2024. Verfasst von Joyce En-Hua Wang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Georgetown University School of Medicine, Washington, DC, USA. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Ankle, Reoperation, Talus, Joint Prosthesis. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 50 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Revision of failed total ankle replacement (TAR) is challenging and associated with increased morbidity. Given the increased popularity of TAR in treating end-stage ankle arthritis (ESAA), viable revision options are needed. The objective of this case series is to present a minimum 2-year clinical and radiographic outcomes of patient-specific custom 3D-printed total ankle total talus (TATR) prostheses in this unique subset of patients. METHODS: 19 participants with ESAA and failed primary TAR who underwent TATR by a single surgeon at our institution from 2019 to 2021 were retrospectively identified. All participants were indicated for revision of primary STAR implant (Stryker, Kalamazoo, MI) and underwent replacement with 3D-printed titanium implants based on preoperative CT analysis (Additive Orthopaedics, Little Silver, NJ). Custom components included a mobile-bearing total talus and stemmed tibial system, performed through an anterior approach. Pre- and postoperative patient-reported outcomes were assessed using the Patient Reported Outcomes Measurement Information System (PROMIS). Pre- and postoperative implant alignment was assessed using medial distal tibial angle (MDTA) and tibiotalar angle (TTA) on anteroposterior, and sagittal tibial angle (STA) on lateral weight-bearing plain films. RESULTS: The average patient age was 60.6 (range, 39-77) years, with an average follow-up of 37.9 (range, 25.3-57.5) months. There was statistically significant improvement in all PROMIS domains. Short-term survivorship was 100%, with two participants (11.0%) requiring reoperation for postoperative complications: one underwent open reduction internal fixation of the tibia for a periprosthetic fracture, and another underwent medial gutter debridement and tarsal tunnel release for recurrent pain. There were no significant differences in pre- versus postoperative radiographic alignment measured by MDTA (89.9 vs 86.4), TTA (89.7 vs 88.1), or STA (85.2 vs 85.3). CONCLUSION: Custom 3D-printed TATR is a promising option for revision TAR. There was significant short-term improvement in pain and physical function, with excellent short-term survivorship and an acceptable postoperative complication rate.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedic Surgery, Georgetown University School of Medicine, Washington, DC, USA.
- Department of Orthopedic Surgery, MedStar Georgetown University Hospital, Washington, DC, USA. Electronic address: jd1553@georgetown.edu.
- Department of Orthopedic Surgery, MedStar Georgetown University Hospital, Washington, DC, USA.
Zitieren
APA
Wang, J. E., Day, J., McCann, J., & Cooper, P. (2024). Early results of combined total ankle total talus replacement in the revision setting. Foot and Ankle Surgery. https://doi.org/10.1016/j.fas.2024.03.012
Vancouver
Wang JE, Day J, McCann J, Cooper P. Early results of combined total ankle total talus replacement in the revision setting. Foot and Ankle Surgery. 2024. doi:10.1016/j.fas.2024.03.012
BibTeX
@article{Wang2024,
author = {Wang, Joyce En-Hua and Day, Jonathan and McCann, Julia and Cooper, Paul},
title = {Early results of combined total ankle total talus replacement in the revision setting},
journal = {Foot and Ankle Surgery},
year = {2024},
doi = {10.1016/j.fas.2024.03.012}
}
EUVIMED