Early experience with a 3-D printed porous surface, fixed-bearing, total ankle arthroplasty: A minimum of 2-year follow-up
Foot and Ankle Surgery · 2024
DOI: 10.1016/j.fas.2024.02.008 ↗Kurz gefasst
Fachartikel in der Zeitschrift Foot and Ankle Surgery, 2024. Verfasst von Joseph Duff und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, University of Tennessee College of Medicine Chattanooga, 975 East Third Street, Hospital Box 260, Chattanooga, TN …. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Ankle, Bioprinting, Joint Prosthesis, Osteoarthritis. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 34 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: This is a pilot study reviewing patients undergoing ankle replacement with the 3-D printed INFINITY™ with ADAPTIS™ total ankle arthroplasty (TAA) system. METHODS: A retrospective review was conducted of patients with a minimum two-year follow-up who underwent TAA with the INFINITY™ with ADAPTIS™ implant system. Outcome measures include implant survivorship, complications with subsequent reoperations, patient reported outcomes, and radiologic subsidence or radiolucency. RESULTS: Thirty patients were included with median follow-up of 26 months (range, 24-36). Implant survival rate was 90% (27/30). Two patients experienced linear radiolucency > 2 mm: one required a revision TAA secondary to tibial subsidence; the other patient was asymptomatic and nonprogressive on serial radiographs. No cystic radiolucencies > 5 mm were identified. VAS, PROMIS PF, and FADI scores improved significantly. CONCLUSION: TAA performed with the 3-D printed INFINITY™ with ADAPTIS™ implant technology led to ninety percent short term implant survivorship and improvement in patient reported outcomes with comparable results to other 4th generation arthroplasty systems as a treatment modality for end-stage ankle arthritis. LEVEL OF EVIDENCE: Level III, Retrospective cohort study, Prognostic.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, University of Tennessee College of Medicine Chattanooga, 975 East Third Street, Hospital Box 260, Chattanooga, TN 37403, USA. Electronic address: joseph.duff.eras@gmail.com.
- Department of Orthopaedic Surgery, University of Tennessee College of Medicine Chattanooga, 975 East Third Street, Hospital Box 260, Chattanooga, TN 37403, USA.
Zitieren
APA
Duff, J., Dunson, J., & Doty, J. F. (2024). Early experience with a 3-D printed porous surface, fixed-bearing, total ankle arthroplasty: A minimum of 2-year follow-up. Foot and Ankle Surgery. https://doi.org/10.1016/j.fas.2024.02.008
Vancouver
Duff J, Dunson J, Doty JF. Early experience with a 3-D printed porous surface, fixed-bearing, total ankle arthroplasty: A minimum of 2-year follow-up. Foot and Ankle Surgery. 2024. doi:10.1016/j.fas.2024.02.008
BibTeX
@article{Duff2024,
author = {Duff, Joseph and Dunson, Jordan and Doty, Jesse F},
title = {Early experience with a 3-D printed porous surface, fixed-bearing, total ankle arthroplasty: A minimum of 2-year follow-up},
journal = {Foot and Ankle Surgery},
year = {2024},
doi = {10.1016/j.fas.2024.02.008}
}
EUVIMED