EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyse

Biophotonics—Intraoperative Guidance During Partial Nephrectomy: A Systematic Review and Meta-analysis

Luisa Egen, Greta S Demmel, Maurizio Grilli, Alexander Studier-Fischer, Felix Nickel, Caelan M Haney, Julia Mühlbauer, Friedrich O Hartung, Hanna S Menold, Pietro Piazza, Juan Gomez Rivas, Enrico Checcucci und 7 weitere

European Urology Focus · 2024

DOI: 10.1016/j.euf.2024.01.005 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift European Urology Focus, 2024. Verfasst von Luisa Egen und 18 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology and Urosurgery, University Medical Center Mannheim, Medical Faculty Mannheim at Heidelberg University, Mannheim, Germany. Elect…. Hauptthemen laut MEDLINE: Nephrectomy. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 60 Literaturangaben. Gefördert von: Else Kröner-Fresenius-Stiftung.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

CONTEXT: Partial nephrectomy (PN) with intraoperative guidance by biophotonics has the potential to improve surgical outcomes due to higher precision. However, its value remains unclear since high-level evidence is lacking. OBJECTIVE: To provide a comprehensive analysis of biophotonic techniques used for intraoperative real-time assistance during PN. EVIDENCE ACQUISITION: We performed a comprehensive database search based on the PICO criteria, including studies published before October 2022. Two independent reviewers screened the titles and abstracts followed by full-text screening of eligible studies. For a quantitative analysis, a meta-analysis was conducted. EVIDENCE SYNTHESIS: In total, 35 studies were identified for the qualitative analysis, including 27 studies on near-infrared fluorescence (NIRF) imaging using indocyanine green, four studies on hyperspectral imaging, two studies on folate-targeted molecular imaging, and one study each on optical coherence tomography and 5-aminolevulinic acid. The meta-analysis investigated seven studies on selective arterial clamping using NIRF. There was a significantly shorter warm ischemia time in the NIRF-PN group (mean difference [MD]: -2.9; 95% confidence interval [CI]: -5.6, -0.1; p = 0.04). No differences were noted regarding transfusions (odds ratio [OR]: 0.5; 95% CI: 0.2, 1.7; p = 0.27), positive surgical margins (OR: 0.7; 95% CI: 0.2, 2.0; p = 0.46), or major complications (OR: 0.4; 95% CI: 0.1, 1.2; p = 0.08). In the NIRF-PN group, functional results were favorable at short-term follow-up (MD of glomerular filtration rate decline: 7.6; 95% CI: 4.6, 10.5; p < 0.01), but leveled off at long-term follow-up (MD: 7.0; 95% CI: -2.8, 16.9; p = 0.16). Remarkably, these findings were not confirmed by the included randomized controlled trial. CONCLUSIONS: Biophotonics comprises a heterogeneous group of imaging modalities that serve intraoperative decision-making and guidance. Implementation into clinical practice and cost effectiveness are the limitations that should be addressed by future research. PATIENT SUMMARY: We reviewed the application of biophotonics during partial removal of the kidney in patients with kidney cancer. Our results suggest that these techniques support the surgeon in successfully performing the challenging steps of the procedure.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

NephrectomyHumansKidney NeoplasmsSurgery, Computer-AssistedOptical ImagingIntraoperative CareIndocyanine GreenOptics and Photonics

Stichwörter der Autor:innen

BiophotonicsIntraoperative guidanceKidney cancerPartial nephrectomySelective clamping

Substanzen

Indocyanine Green

Autor:innen und Institutionen

  • Department of Urology and Urosurgery, University Medical Center Mannheim, Medical Faculty Mannheim at Heidelberg University, Mannheim, Germany. Electronic address: luisa.egen@umm.de.
  • Department of Urology and Urosurgery, University Medical Center Mannheim, Medical Faculty Mannheim at Heidelberg University, Mannheim, Germany.
  • Library of the Medical Faculty Mannheim at Heidelberg University, Mannheim, Germany.
  • Department of General, Visceral, and Transplantation Surgery, Heidelberg University Hospital, Heidelberg, Germany.
  • Department of General, Visceral, and Thoracic Surgery, University Hospital Hamburg-Eppendorf, Hamburg, Germany.
  • Department of Urology, University Hospital Leipzig, Leipzig, Germany.

Förderung

  • Else Kröner-Fresenius-Stiftung

Zitieren

APA

Egen, L., Demmel, G. S., Grilli, M., Studier-Fischer, A., Nickel, F., Haney, C. M., Mühlbauer, J., Hartung, F. O., Menold, H. S., Piazza, P., Rivas, J. G., Checcucci, E., Puliatti, S., Belenchon, I. R., Taratkin, M., Rodler, S., Cacciamani, G., Michel, M. S., & Kowalewski, K. F. (2024). Biophotonics—Intraoperative Guidance During Partial Nephrectomy: A Systematic Review and Meta-analysis. European Urology Focus. https://doi.org/10.1016/j.euf.2024.01.005

Vancouver

Egen L, Demmel GS, Grilli M, Studier-Fischer A, Nickel F, Haney CM, et al. Biophotonics—Intraoperative Guidance During Partial Nephrectomy: A Systematic Review and Meta-analysis. European Urology Focus. 2024. doi:10.1016/j.euf.2024.01.005

BibTeX
@article{Egen2024,
  author = {Egen, Luisa and Demmel, Greta S and Grilli, Maurizio and Studier-Fischer, Alexander and Nickel, Felix and Haney, Caelan M and Mühlbauer, Julia and Hartung, Friedrich O and Menold, Hanna S and Piazza, Pietro and Rivas, Juan Gomez and Checcucci, Enrico and Puliatti, Stefano and Belenchon, Ines Rivero and Taratkin, Mark and Rodler, Severin and Cacciamani, Giovanni and Michel, Maurice S and Kowalewski, Karl-Friedrich},
  title = {Biophotonics—Intraoperative Guidance During Partial Nephrectomy: A Systematic Review and Meta-analysis},
  journal = {European Urology Focus},
  year = {2024},
  doi = {10.1016/j.euf.2024.01.005}
}
Kostenlos starten →