A data-driven sensor placement approach for detecting voltage violations in distribution systems
Electric Power Systems Research · 2024-07 · 232 · 110387
DOI: 10.1016/j.epsr.2024.110387 ↗Kurz gefasst
Fachartikel in der Zeitschrift Electric Power Systems Research, 2024-07. Verfasst von Paprapee Buason und 3 weiteren Autor:innen. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: United States Department of Energy Office of Electricity, U.S. Department of Energy, Power Systems Engineering Research Center.
Abstract (Originalsprache)
Stochastic fluctuations in power injections from distributed energy resources (DERs) combined with load variability can cause constraint violations (e.g., exceeded voltage limits) in electric distribution systems. To monitor grid operations, sensors are placed to measure important quantities such as the voltage magnitudes. In this paper, we consider a sensor placement problem which seeks to identify locations for installing sensors that can capture all possible violations of voltage magnitude limits. We formulate a bilevel optimization problem that minimizes the number of sensors and avoids false sensor alarms in the upper level while ensuring detection of any voltage violations in the lower level. This problem is challenging due to the nonlinearity of the power flow equations and the presence of binary variables. Accordingly, we employ recently developed conservative linear approximations of the power flow equations that overestimate or underestimate the voltage magnitudes. By replacing the nonlinear power flow equations with conservative linear approximations, we can ensure that the resulting sensor locations and thresholds are sufficient to identify any constraint violations. Additionally, we apply various problem reformulations to significantly improve computational tractability while simultaneously ensuring an appropriate placement of sensors. Lastly, we improve the quality of the results via an approximate gradient descent method that adjusts the sensor thresholds. We demonstrate the effectiveness of our proposed method for several test cases, including a system with multiple switching configurations.
Förderung
- United States Department of Energy Office of Electricity
- U.S. Department of Energy
- Power Systems Engineering Research Center
- National Science Foundation
Zitieren
APA
Buason, P., Misra, S., Talkington, S., & Molzahn, D. K. (2024). A data-driven sensor placement approach for detecting voltage violations in distribution systems. Electric Power Systems Research, 232, 110387. https://doi.org/10.1016/j.epsr.2024.110387
Vancouver
Buason P, Misra S, Talkington S, Molzahn DK. A data-driven sensor placement approach for detecting voltage violations in distribution systems. Electric Power Systems Research. 2024;232:110387. doi:10.1016/j.epsr.2024.110387
BibTeX
@article{Buason2024,
author = {Buason, Paprapee and Misra, Sidhant and Talkington, Samuel and Molzahn, Daniel K.},
title = {A data-driven sensor placement approach for detecting voltage violations in distribution systems},
journal = {Electric Power Systems Research},
year = {2024},
volume = {232},
pages = {110387},
doi = {10.1016/j.epsr.2024.110387}
}
EUVIMED