Spatiotemporal contamination characteristics, bacterial community structure, and airflow-mediated transport of bacterial aerosols in a pediatric emergency consulting room
Environmental Research · 2026
DOI: 10.1016/j.envres.2026.125789 ↗Kurz gefasst
Fachartikel in der Zeitschrift Environmental Research, 2026. Verfasst von Zhijian Liu und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Power Engineering, North China Electric Power University, Baoding, Hebei, 071003, China. Hauptthemen laut MEDLINE: Air Microbiology, Bacteria, Emergency Service, Hospital, Air Pollution, Indoor. Die Arbeit nennt 60 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities, National Science and Technology Major Project.
Abstract (Originalsprache)
Pediatric emergency consulting rooms are characterized by high occupant density and frequent close-range interactions, creating potential hotspots for microbial aerosol exposure and cross-transmission in hospital built environments. However, microbial contamination and its spatial heterogeneity across different environmental media in pediatric emergency consulting rooms under routine clinical conditions remain insufficiently characterized. This study investigated a pediatric internal medicine emergency consulting room in a children's hospital to clarify bacterial contamination characteristics and airflow-driven transport mechanisms. Field sampling of culturable bacteria, high-throughput sequencing, and computational fluid dynamics simulations were combined to analyze airborne and surface contamination, culturable bacterial community structure, aerosol transport, deposition, and infection risk. The results showed limited differences in culturable airborne bacteria among sampling locations, likely reflecting ventilation-driven mixing within the small consulting room, whereas surface deposition exhibited pronounced spatial heterogeneity, with higher contamination on the floor and some wall surfaces. Bacterial aerosols smaller than 3.3 μm accounted for 73.47% of the total, indicating respirable fine particles as the dominant exposure fraction. Bacillota, Pseudomonadota, and Actinomycetota dominated the culturable bacterial communities, with Staphylococcus as the core genus. Numerical simulations indicated that airflow organization significantly affected aerosol dispersion and deposition, producing localized high-concentration and high-risk regions around the occupants and consultation desk. The consultation desk and floor accounted for 79.71% of the total deposited particles. These findings provide scenario-specific evidence for ventilation optimization, targeted disinfection, and exposure control in comparable pediatric emergency consulting environments.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Power Engineering, North China Electric Power University, Baoding, Hebei, 071003, China.
- Beijing Children's Hospital Capital Medical University, Beijing, 100045, China.
- Baoding Hospital of Beijing Children's Hospital Capital Medical University, Baoding, Hebei, 071003, China.
- Department of Power Engineering, North China Electric Power University, Baoding, Hebei, 071003, China. Electronic address: haiyangliu@ncepu.edu.cn.
- Beijing Children's Hospital Capital Medical University, Beijing, 100045, China. Electronic address: tianjian72@hotmail.com.
Förderung
- National Natural Science Foundation of China
- Fundamental Research Funds for the Central Universities
- National Science and Technology Major Project
- Natural Science Foundation of Hebei Province
- National Major Science and Technology Projects of China
Zitieren
APA
Liu, Z., Shang, Z., Wang, X., Hu, L., Hu, T., Wang, X., Liu, X., Wang, Y., Peng, Y., Liu, H., & Tian, J. (2026). Spatiotemporal contamination characteristics, bacterial community structure, and airflow-mediated transport of bacterial aerosols in a pediatric emergency consulting room. Environmental Research. https://doi.org/10.1016/j.envres.2026.125789
Vancouver
Liu Z, Shang Z, Wang X, Hu L, Hu T, Wang X, et al. Spatiotemporal contamination characteristics, bacterial community structure, and airflow-mediated transport of bacterial aerosols in a pediatric emergency consulting room. Environmental Research. 2026. doi:10.1016/j.envres.2026.125789
BibTeX
@article{Liu2026,
author = {Liu, Zhijian and Shang, Zikai and Wang, Xiao and Hu, Lina and Hu, Tianyang and Wang, Xiaohui and Liu, Xinhui and Wang, Yingying and Peng, Yaguang and Liu, Haiyang and Tian, Jian},
title = {Spatiotemporal contamination characteristics, bacterial community structure, and airflow-mediated transport of bacterial aerosols in a pediatric emergency consulting room},
journal = {Environmental Research},
year = {2026},
doi = {10.1016/j.envres.2026.125789}
}
EUVIMED