EUVIMEDEUVIMED entdecken
Crossref

Polymer-based recyclable solid-phase optical sensor to quantify Hg2+ in aqueous samples

Sangeetha Krishna Kumar, Lingesh Gopalakrishnan, Prabhakaran Srinivasan, Deepan Kumar Madhu, Prabhakaran Deivasigamani, Akhila Maheswari Mohan

Environmental Research · 2025-11 · 285 · 122595

DOI: 10.1016/j.envres.2025.122595 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Environmental Research, 2025-11. Verfasst von Sangeetha Krishna Kumar und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, School of Advanced Sciences, Vellore Institute of Technology (VIT), Vellore, Tamil Nadu, 632014, India. Hauptthemen laut MEDLINE: Mercury, Water Pollutants, Chemical, Polymers, Environmental Monitoring. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: Vellore Institute of Technology, Board of Research in Nuclear Sciences.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this work, we engineered a facile and portable solid-state sensor for the selective colorimetric detection of toxic Hg2+. The sensor architecture was based on a hierarchically organized macro/mesoporous polymeric monolith, which provided a highly ordered porous framework and substantial surface area features that significantly enhanced the immobilization efficiency of the chromoionophoric probe and facilitated the capture of trace-level analytes in the sub-ppb concentration range. The chromoionophore, DPQD, was synthetically tailored and subsequently integrated into a poly(acrylic acid-co-trimethylolpropane triacrylate) [poly(AA-co-TMPTA)] monolithic matrix via a robust physisorptive method. The morphological and physicochemical characteristics of the functionalized monolith were elucidated using a suite of analytical techniques, including scanning electron microscopy (SEM), transmission electron microscopy (TEM), ultraviolet-visible spectroscopy (UV-Vis), Fourier transform infrared spectroscopy (FTIR), and X-ray diffraction (XRD). Upon interaction with Hg2+, the spatially confined DPQD moieties form a stable 2:1 charge-transfer complex, eliciting a pronounced chromogenic transition from light yellow to deep orange. The resultant poly(AA-co-TMPTA)DPQD sensor demonstrated exceptional selectivity for Hg2+ over a broad array of potentially interfering metal ions, achieving a low detection threshold of 0.23 ppb and a linear response range spanning 0.02-100 ppb. The sensor also exhibited commendable operational durability, retaining over 90 % of its initial sensing efficacy after seven consecutive reuse cycles. Validation studies conducted using environmental water samples, simulated industrial wastewater, and tobacco extract matrices confirmed the sensor's practical applicability, yielding high recovery rates and excellent reproducibility, thereby underscoring its utility for real-time, in situ monitoring of mercury contamination in complex sample environments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MercuryWater Pollutants, ChemicalPolymersEnvironmental MonitoringColorimetry

Stichwörter der Autor:innen

Chromogenic sensorMercuryPorous polymerSolid-state

Substanzen

MercuryWater Pollutants, ChemicalPolymers

Autor:innen und Institutionen

  • Department of Chemistry, School of Advanced Sciences, Vellore Institute of Technology (VIT), Vellore, Tamil Nadu, 632014, India.
  • Department of Chemistry, Indian Institute of Technology (IIT), Bombay, Mumbai, Maharashtra, 400076, India.
  • Department of Chemistry, K. Ramakrishnan College of Technology, Tiruchirappalli, Tamil Nadu, 621112, India.
  • Department of Chemistry, School of Advanced Sciences, Vellore Institute of Technology (VIT), Vellore, Tamil Nadu, 632014, India. Electronic address: prabhakaran.d@vit.ac.in.
  • Department of Chemistry, School of Advanced Sciences, Vellore Institute of Technology (VIT), Vellore, Tamil Nadu, 632014, India. Electronic address: akhila.maheswari@vit.ac.in.

Förderung

  • Vellore Institute of Technology
  • Board of Research in Nuclear Sciences

Zitieren

APA

Krishna Kumar, S., Gopalakrishnan, L., Srinivasan, P., Madhu, D. K., Deivasigamani, P., & Mohan, A. M. (2025). Polymer-based recyclable solid-phase optical sensor to quantify Hg2+ in aqueous samples. Environmental Research, 285, 122595. https://doi.org/10.1016/j.envres.2025.122595

Vancouver

Krishna Kumar S, Gopalakrishnan L, Srinivasan P, Madhu DK, Deivasigamani P, Mohan AM. Polymer-based recyclable solid-phase optical sensor to quantify Hg2+ in aqueous samples. Environmental Research. 2025;285:122595. doi:10.1016/j.envres.2025.122595

BibTeX
@article{KrishnaKumar2025,
  author = {Krishna Kumar, Sangeetha and Gopalakrishnan, Lingesh and Srinivasan, Prabhakaran and Madhu, Deepan Kumar and Deivasigamani, Prabhakaran and Mohan, Akhila Maheswari},
  title = {Polymer-based recyclable solid-phase optical sensor to quantify Hg2+ in aqueous samples},
  journal = {Environmental Research},
  year = {2025},
  volume = {285},
  pages = {122595},
  doi = {10.1016/j.envres.2025.122595}
}
Kostenlos starten →