Electrochemically microplastic detection using chitosan-magnesium oxide nanosheet
Environmental Research · 2024
DOI: 10.1016/j.envres.2024.118894 ↗Kurz gefasst
Fachartikel in der Zeitschrift Environmental Research, 2024. Verfasst von Ashab Noumani und 4 weiteren Autor:innen. Beteiligte Einrichtung: Nano-Bio Laboratory, Special Center for Nanoscience, Jawaharlal Nehru University, New Delhi, India. Hauptthemen laut MEDLINE: Chitosan, Electrochemical Techniques, Microplastics, Magnesium Oxide. Die Arbeit wurde bisher 34-mal zitiert (Crossref) und nennt 64 Literaturangaben. Gefördert von: Department of Science and Technology, Ministry of Science and Technology, India.
Abstract (Originalsprache)
Microplastics, an invisible threat, are emerging as serious pollutants that continuously affect health by interrupting/contaminating the human cycle, mainly involving food, water, and air. Such serious scenarios raised the demand for developing efficient sensing systems to detect them at an early stage efficiently and selectively. In this direction, the proposed research reports an electrochemical hexamethylenetetramine (HMT) sensing utilizing a sensing platform fabricated using chitosan-magnesium oxide nanosheets (CHIT-MgO NS) nanocomposite. HMT is considered as a hazardous microplastic, which is used as an additive in plastic manufacturers and has been selected as a target analyte. To fabricate sensing electrodes, a facile co-precipitation technique was employed to synthesize MgO NS, which was further mixed with 1% CHIT solution to form a CHIT_MgO NS composite. Such prepared nanocomposite solution was then drop casted to an indium tin oxide (ITO) to fabricate CHIT_MgO NS/ITO sensing electrode to detect HMT electrochemically using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. To determine the limit of detection (LOD) and sensitivity, DPV was performed. The resulting calibrated curve for HMT, ranging from 0.5 μM to 4.0 μM, exhibited a sensitivity of 12.908 μA (μM)-1 cm-2 with a detection limit of 0.03 μM and a limit of quantitation (LOQ) of 0.10 μM. Further, the CHIT_MgO NS/ITO modified electrode was applied to analyze HMT in various real samples, including river water, drain water, packaged water, and tertiary processed food. The results demonstrated the method's high sensitivity and suggested its potential applications in the field of microplastic surveillance, with a focus on health management.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Nano-Bio Laboratory, Special Center for Nanoscience, Jawaharlal Nehru University, New Delhi, India.
- NanoBioTech Laboratory, Department of Environmental Engineering, Florida Polytechnic University, Lakeland, 33805, FL, USA; School of Engineering, University of Petroleum and Energy Studies (UPES), Dehradun, Uttarakhand,…
- School of Advanced Materials and Nanotechnology, Xidian University, Xi'an Province, 710071, China.
- Nano-Bio Laboratory, Special Center for Nanoscience, Jawaharlal Nehru University, New Delhi, India. Electronic address: partima@mail.jnu.ac.in.
Förderung
- Department of Science and Technology, Ministry of Science and Technology, India
Zitieren
APA
Noumani, A., Verma, D., Kaushik, A., Khosla, A., & Solanki, P. R. (2024). Electrochemically microplastic detection using chitosan-magnesium oxide nanosheet. Environmental Research. https://doi.org/10.1016/j.envres.2024.118894
Vancouver
Noumani A, Verma D, Kaushik A, Khosla A, Solanki PR. Electrochemically microplastic detection using chitosan-magnesium oxide nanosheet. Environmental Research. 2024. doi:10.1016/j.envres.2024.118894
BibTeX
@article{Noumani2024,
author = {Noumani, Ashab and Verma, Damini and Kaushik, Ajeet and Khosla, Ajit and Solanki, Pratima R},
title = {Electrochemically microplastic detection using chitosan-magnesium oxide nanosheet},
journal = {Environmental Research},
year = {2024},
doi = {10.1016/j.envres.2024.118894}
}
EUVIMED