Application of cobalt-cerium-iron ternary layered double hydroxide for extraction of perfluorooctane sulfonate followed by HPLC-MS/MS analysis
Environmental Research · 2024
DOI: 10.1016/j.envres.2024.118838 ↗Kurz gefasst
Fachartikel in der Zeitschrift Environmental Research, 2024. Verfasst von Samira Arefi-Oskoui und 3 weiteren Autor:innen. Beteiligte Einrichtung: Research Laboratory of Advanced Water and Wastewater Treatment Processes, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz…. Hauptthemen laut MEDLINE: Alkanesulfonic Acids, Tandem Mass Spectrometry, Fluorocarbons, Hydroxides. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 58 Literaturangaben.
Abstract (Originalsprache)
Herein, Ce-doped CoFe layered double hydroxide (LDH), noted as CoCeFe ternary LDH, was prepared using the co-precipitation route. Prosperous synthesis of CoFe LDH and successful partial replacement of iron cations with cerium cations in CoCeFe ternary LDH were confirmed by X-ray diffraction patterns, energy-dispersive X-ray spectroscopy, and elemental dot-mapping images. Nanosheet morphology was recognized for both CoFe LDH and CoCeFe ternary LDH from scanning electron microscopy and transmission electron microscopy micrographs. In the following, a dispersive solid phase extraction (DSPE) method was developed using the synthesized CoCeFe ternary LDH as a sorbent for extracting perfluorooctanesulfonic acid (PFOS) from wastewater samples. For the selective analysis of PFOS, high-performance liquid chromatography-tandem mass spectroscopy (HPLC-MS/MS) in multiple reaction monitoring mode was used. Analytical parameters such as the limit of detection equal to 0.02 μg/L, with a linear range of 0.05-300 μg/L, the limit of quantification equal to 0.05 μg/L, and an enrichment factor equal to 23.3 were achieved for PFOS at the optimized condition (sorbent: 5 mg of CoCeFe ternary LDH, eluent type and volume: 150 μL mobile phase, pH: 3, adsorption time: 3 min, and desorption time: 5 min). The developed strategy for the analysis of PFOS was tested in real wastewater samples, including copper mine and petrochemical wastewater. The amount of analytes in real samples was calculated using the standard addition method, and good relative recovery in the range of 86%-105% was obtained. The main novelty of this research is the application of CoCeFe ternary LDH to extract the PFOS from wastewater using the DSPE method for determination by HPLC-MS/MS.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Research Laboratory of Advanced Water and Wastewater Treatment Processes, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, 51666-16471, Tabriz, Iran.
- Research Laboratory of Advanced Water and Wastewater Treatment Processes, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, 51666-16471, Tabriz, Iran; Department of Chemical Engineering, Istan…
- Department of Chemistry and Chemical Technology, Al-Farabi Kazakh National University, Al-Farabi 71, Almaty, 050038, Kazakhstan.
Zitieren
APA
Arefi-Oskoui, S., Khataee, A., Marzi Khosrowshahi, E., & Kudaibergenov, N. (2024). Application of cobalt-cerium-iron ternary layered double hydroxide for extraction of perfluorooctane sulfonate followed by HPLC-MS/MS analysis. Environmental Research. https://doi.org/10.1016/j.envres.2024.118838
Vancouver
Arefi-Oskoui S, Khataee A, Marzi Khosrowshahi E, Kudaibergenov N. Application of cobalt-cerium-iron ternary layered double hydroxide for extraction of perfluorooctane sulfonate followed by HPLC-MS/MS analysis. Environmental Research. 2024. doi:10.1016/j.envres.2024.118838
BibTeX
@article{ArefiOskoui2024,
author = {Arefi-Oskoui, Samira and Khataee, Alireza and Marzi Khosrowshahi, Elnaz and Kudaibergenov, Nurbolat},
title = {Application of cobalt-cerium-iron ternary layered double hydroxide for extraction of perfluorooctane sulfonate followed by HPLC-MS/MS analysis},
journal = {Environmental Research},
year = {2024},
doi = {10.1016/j.envres.2024.118838}
}
EUVIMED