Iridium oxide-based non-enzymatic glucose sensor: Superior electro-catalytic performance in biological environmental media
Environmental Research · 2024-07 · 252 · 118772
DOI: 10.1016/j.envres.2024.118772 ↗Kurz gefasst
Fachartikel in der Zeitschrift Environmental Research, 2024-07. Verfasst von Ji Hwan Jeon und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Material Science and Chemical Engineering, Hanyang University, Ansan, 15588, South Korea. Hauptthemen laut MEDLINE: Iridium. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: Hanyang University.
Abstract (Originalsprache)
Nanostructured inorganic materials have potential advantages as glucose-sensing elements in diabetes care, thereby circumventing the need for expensive enzymatic agents. However, many nonenzymatic sensors face challenges related to selectivity and reliability, reducing their efficacy in body fluids. In this study, we introduce an Iridium oxide (IrO2)-based non-enzymatic glucose sensor. This sensor demonstrates exceptional electro-catalytic properties in human serum, characterized by high sensitivity (638 μA μM-1cm2) and a consistent recovery rate (∼104%) across 15 cycles in saline. Furthermore, its impressive performance in human serum, as evidenced by a low relative standard deviation (RSD
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Material Science and Chemical Engineering, Hanyang University, Ansan, 15588, South Korea.
- Major of Human Biocovergence, Division of Smart Healthcare, Pukyong National University, Busan, 48513, South Korea.
- Department of Material Science and Chemical Engineering, Hanyang University, Ansan, 15588, South Korea. Electronic address: jiyoung3073@hanyang.ac.kr.
- Department of Material Science and Chemical Engineering, Hanyang University, Ansan, 15588, South Korea. Electronic address: choa15@hanyang.ac.kr.
Förderung
- Hanyang University
Zitieren
APA
Jeon, J. H., Lim, H. R., Park, J. Y., & Choa, Y. H. (2024). Iridium oxide-based non-enzymatic glucose sensor: Superior electro-catalytic performance in biological environmental media. Environmental Research, 252, 118772. https://doi.org/10.1016/j.envres.2024.118772
Vancouver
Jeon JH, Lim HR, Park JY, Choa YH. Iridium oxide-based non-enzymatic glucose sensor: Superior electro-catalytic performance in biological environmental media. Environmental Research. 2024;252:118772. doi:10.1016/j.envres.2024.118772
BibTeX
@article{Jeon2024,
author = {Jeon, Ji Hwan and Lim, Hyo-Ryoung and Park, Ji Young and Choa, Yong-Ho},
title = {Iridium oxide-based non-enzymatic glucose sensor: Superior electro-catalytic performance in biological environmental media},
journal = {Environmental Research},
year = {2024},
volume = {252},
pages = {118772},
doi = {10.1016/j.envres.2024.118772}
}
EUVIMED