Standardizing microplastic quantification by scanning electron microscopy: Structural performance of filter membranes and implications from bottled drink analysis
Environmental Pollution · 2026-09 · 405 · 128585
DOI: 10.1016/j.envpol.2026.128585 ↗Kurz gefasst
Fachartikel in der Zeitschrift Environmental Pollution, 2026-09. Verfasst von Qian Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Water Pollution and Green Resource Recycling, School of the Environment, Nanjing University, Nanjing, 210023, China. Hauptthemen laut MEDLINE: Microplastics, Membranes, Artificial, Filtration. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: Jiangsu Province Natural Science Foundation, National Natural Science Foundation of China.
Abstract (Originalsprache)
Filtration methods are widely used for microplastic (MP) isolation, yet filter membrane selection can introduce substantial bias into MP quantification. In this study, five types of membranes, classified as single-layer-hole [polycarbonate track-etched (PCTE)], multilayer-fiber [polytetrafluoroethylene (PTFE) and glass fiber (GF)], and multilayer-hole [mixed cellulose esters (MCE) and nylon (NY)], were systematically compared for MP quantification. Particle abundance was quantified by scanning electron microscopy (SEM)-based visual counting on membranes. Polystyrene (PS) microspheres exhibited superior dispersion on single-layer-hole (PCTE) and multilayer-fiber (PTFE) membranes. However, partial particle embedding occurred in multilayer-fiber membranes (PTFE and GF), whereas pronounced aggregation occurred on multilayer-hole membranes (MCE and NY). Accordingly, PCTE exhibited the most stable quantification performance across PS concentrations and pH conditions, with RSD values of 3.05-17.68%. Application to bottled drinks further showed that PCTE improved the differentiation of particle abundance among brands. LDIR analysis indicated that the collected particles from bottled drinks consisted of both MPs, mainly polyethylene terephthalate, polyethylene, polybutadiene rubber, and polyvinyl chloride, as well as non-MPs (54.50% - 81.29%). Overall, selection of appropriate membranes is critical for MP quantification, and single-layer-hole PCTE membranes are recommended for reliable visual counting and improved comparability across studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- State Key Laboratory of Water Pollution and Green Resource Recycling, School of the Environment, Nanjing University, Nanjing, 210023, China.
- State Key Laboratory of Water Pollution and Green Resource Recycling, School of the Environment, Nanjing University, Nanjing, 210023, China. Electronic address: lizzycui@nju.edu.cn.
Förderung
- Jiangsu Province Natural Science Foundation
- National Natural Science Foundation of China
Zitieren
APA
Zhang, Q., Xu, X., Zhang, D., Song, C., Li, C., & Cui, X. (2026). Standardizing microplastic quantification by scanning electron microscopy: Structural performance of filter membranes and implications from bottled drink analysis. Environmental Pollution, 405, 128585. https://doi.org/10.1016/j.envpol.2026.128585
Vancouver
Zhang Q, Xu X, Zhang D, Song C, Li C, Cui X. Standardizing microplastic quantification by scanning electron microscopy: Structural performance of filter membranes and implications from bottled drink analysis. Environmental Pollution. 2026;405:128585. doi:10.1016/j.envpol.2026.128585
BibTeX
@article{Zhang2026,
author = {Zhang, Qian and Xu, Xinyan and Zhang, Dengke and Song, Chenzhuo and Li, Chenle and Cui, Xinyi},
title = {Standardizing microplastic quantification by scanning electron microscopy: Structural performance of filter membranes and implications from bottled drink analysis},
journal = {Environmental Pollution},
year = {2026},
volume = {405},
pages = {128585},
doi = {10.1016/j.envpol.2026.128585}
}
EUVIMED