EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Analysing the impact of diesel trains on air quality in a semi-enclosed railway station through mixed monitoring methods and XGBoost modelling

Shanmuga Priyan, Muireann Kearney, Neha Jacob, Yuxuan Guo, Madhavan Vasudevan, Aonghus McNabola, Brian M Broderick, Brian Caulfield, Margaret O'Mahony, John Gallagher

Environmental Pollution · 2026

DOI: 10.1016/j.envpol.2026.128029 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Environmental Pollution, 2026. Verfasst von Shanmuga Priyan und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Civil, Structural, and Environmental Engineering, Trinity College Dublin, The University of Dublin, Dublin 2, Ireland. Electronic addre…. Hauptthemen laut MEDLINE: Environmental Monitoring, Air Pollutants, Air Pollution, Vehicle Emissions. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Environmental Protection Agency, Department of Transport.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study assessed air quality in a semi-enclosed train station using both personal and fixed monitoring and applied eXtreme Gradient Boosting (XGBoost) modelling to identify key factors influencing pollutant levels. The investigation also examined the effects of train idling time and engine speed on fuel consumption and pollutant emissions. Personal monitoring showed the average PM2.5 concentrations of 17-137 μg/m3 during active train operations, with higher levels observed in enclosed platforms and when diesel multiple unit (DMU) trains were present. Continuous fixed monitoring captured 24-h average concentrations of 3.18-32.56 μg/m3 for PM2.5, with DMU-dominated platforms exceeding WHO PM2.5 limits during 90% of the monitoring period. The 24-h average NO2 levels ranged from 135.6 to 169.8 μg/m3, with 11-15% of hourly values in a month exceeding the EU hourly limit. The XGBoost model demonstrated a moderate fit (RMSE: 15.12 μg/m3, R2: 0.61) and identified ambient temperature and average train idling time as the most influential predictors of NO2 levels. Partial dependence analysis indicated that reducing average idling time by 2 min could reduce NO2 concentrations by approximately 2.5 μg/m3 per train. Operational analysis suggests shutting down engines when the next operation is more than 30 min, restarting them 15 min before departure, and maintaining idle speeds below 600 RPM. These measures could save over 7,000 L of diesel per month, reduce fuel consumption by 40-45%, and lower NOx and PM emissions by around 54%, offering actionable strategies to improve station air quality.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Environmental MonitoringAir PollutantsAir PollutionVehicle EmissionsRailroadsGasolineBoosting Machine Learning AlgorithmsParticulate Matter

Stichwörter der Autor:innen

Air quality sensorsDiesel trainsFuel consumptionRailway stationTrain idling time

Substanzen

Air PollutantsVehicle EmissionsParticulate MatterGasoline

Autor:innen und Institutionen

  • Department of Civil, Structural, and Environmental Engineering, Trinity College Dublin, The University of Dublin, Dublin 2, Ireland. Electronic address: rs10@tcd.ie.
  • Department of Civil, Structural, and Environmental Engineering, Trinity College Dublin, The University of Dublin, Dublin 2, Ireland.
  • Department of Civil, Structural, and Environmental Engineering, Trinity College Dublin, The University of Dublin, Dublin 2, Ireland; Centre for Transport Research and Innovation for People, Trinity College Dublin, The U…
  • School of Engineering, RMIT University, 124 La Trobe St, Melbourne, VIC, 3000, Australia.

Förderung

  • Environmental Protection Agency
  • Department of Transport

Zitieren

APA

Priyan, S., Kearney, M., Jacob, N., Guo, Y., Vasudevan, M., McNabola, A., Broderick, B. M., Caulfield, B., O'Mahony, M., & Gallagher, J. (2026). Analysing the impact of diesel trains on air quality in a semi-enclosed railway station through mixed monitoring methods and XGBoost modelling. Environmental Pollution. https://doi.org/10.1016/j.envpol.2026.128029

Vancouver

Priyan S, Kearney M, Jacob N, Guo Y, Vasudevan M, McNabola A, et al. Analysing the impact of diesel trains on air quality in a semi-enclosed railway station through mixed monitoring methods and XGBoost modelling. Environmental Pollution. 2026. doi:10.1016/j.envpol.2026.128029

BibTeX
@article{Priyan2026,
  author = {Priyan, Shanmuga and Kearney, Muireann and Jacob, Neha and Guo, Yuxuan and Vasudevan, Madhavan and McNabola, Aonghus and Broderick, Brian M and Caulfield, Brian and O'Mahony, Margaret and Gallagher, John},
  title = {Analysing the impact of diesel trains on air quality in a semi-enclosed railway station through mixed monitoring methods and XGBoost modelling},
  journal = {Environmental Pollution},
  year = {2026},
  doi = {10.1016/j.envpol.2026.128029}
}
Kostenlos starten →