Machine learning models for predicting indoor airborne fungal concentrations in public facilities utilizing environmental variables
Environmental Pollution · 2025
DOI: 10.1016/j.envpol.2025.125684 ↗Kurz gefasst
Fachartikel in der Zeitschrift Environmental Pollution, 2025. Verfasst von Bong Gu Lee und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Applied Environmental Science, Graduate School Kyung Hee University, 1732 Deogyeong-daero, Giheung-gu, Yongin-si, Gyeonggi-do, 17104, R…. Hauptthemen laut MEDLINE: Air Pollution, Indoor, Machine Learning, Fungi, Environmental Monitoring. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: Ministry of Environment, Korea Environmental Industry and Technology Institute.
Abstract (Originalsprache)
Airborne fungi are major contributors to substandard indoor air quality, with potential implications for public health, especially in public facilities. The risk of chronic exposure can be significantly reduced by accurately predicting airborne fungal concentrations. To manage indoor air quality, we developed machine learning (ML) models that predict airborne fungal concentrations in public facilities by utilizing environmental variables, such as facility type, floor, month, air temperature, relative humidity, coarse particulate matter (PM)2.5-10, and 2-day accumulated precipitation. A gene-based assay with high specificity and sensitivity was used to measure the fungal concentrations. The Gradient Boosting (GB) model exhibited superior performance among the seven developed models, achieving an R2 of 0.78 on the test set. SHapley Additive exPlanations (SHAP) analysis was performed to evaluate the significance of the features. According to our findings, day care centers had the most substantial influence on fungal concentrations compared to those of other facilities. The impact of the 2-day accumulated below-average precipitation was more significant than that of extreme precipitation in increasing fungal concentrations. Furthermore, fungal concentrations were positively correlated with air temperature, coarse PM2.5-10, and relative humidity. Based on these findings, we may provide fundamental insights into airborne fungal concentrations and the environmental variables that influence them, while the GB model developed herein can serve as a tool for assessing microbial contamination in public facilities.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Applied Environmental Science, Graduate School Kyung Hee University, 1732 Deogyeong-daero, Giheung-gu, Yongin-si, Gyeonggi-do, 17104, Republic of Korea.
- Department of Applied Environmental Science, Graduate School Kyung Hee University, 1732 Deogyeong-daero, Giheung-gu, Yongin-si, Gyeonggi-do, 17104, Republic of Korea; Department of Environmental Science and Engineering,…
Förderung
- Ministry of Environment
- Korea Environmental Industry and Technology Institute
Zitieren
APA
Lee, B. G., Jeong, K. H., Kim, H. E., & Yeo, M. K. (2025). Machine learning models for predicting indoor airborne fungal concentrations in public facilities utilizing environmental variables. Environmental Pollution. https://doi.org/10.1016/j.envpol.2025.125684
Vancouver
Lee BG, Jeong KH, Kim HE, Yeo MK. Machine learning models for predicting indoor airborne fungal concentrations in public facilities utilizing environmental variables. Environmental Pollution. 2025. doi:10.1016/j.envpol.2025.125684
BibTeX
@article{Lee2025,
author = {Lee, Bong Gu and Jeong, Ki Heon and Kim, Han Eol and Yeo, Min-Kyeong},
title = {Machine learning models for predicting indoor airborne fungal concentrations in public facilities utilizing environmental variables},
journal = {Environmental Pollution},
year = {2025},
doi = {10.1016/j.envpol.2025.125684}
}
EUVIMED