Rapid generation of aged tire-wear particles using dry-, wet-, and cryo-milling for ecotoxicity testing
Environmental Pollution · 2023-08 · 330 · 121787
DOI: 10.1016/j.envpol.2023.121787 ↗Kurz gefasst
Fachartikel in der Zeitschrift Environmental Pollution, 2023-08. Verfasst von Hyeokjin Shin und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical Engineering, Kwangwoon University, Seoul, 01897, South Korea. Hauptthemen laut MEDLINE: Ecosystem, Environmental Pollutants. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: Korea Environmental Industry and Technology Institute, National Institute of Environmental Research.
Abstract (Originalsprache)
Strict environmental laws have been enacted to regulate the emission of exhaust particulate matter (PM), which is one of the most hazardous pollutants that reduce air quality and pose a serious risk to the human health. In addition, non-exhaust PM, such as road wear, tire wear, and brake wear debris, is a significant source of airborne pollutants. Road dust less than 100 μm in size may include tire wear particles (TWPs), which are broken down into finer particles with sizes on the order of tens of micrometers because of weathering. TWPs can be transported to water bodies via runoff, potentially contaminating water systems and negatively affecting aquatic ecosystems. Therefore, ecotoxicity tests using reference TWPs are required to investigate the impact of TWPs on the human health and environment. In this study, aged TWPs were produced using dry-, wet-, and cryo-milling methods, and the dispersion stability of TWPs in dechlorinated water was evaluated. Aged TWPs prepared by dry- and wet-milling had an average particle size of 20 μm, whereas pristine TWPs had an irregular shape and average particle size of 100 μm. The capacity of the ball-milling cylinder and excessively long 28-d generation time constrain the amount of aged TWPs that can be produced through conventional milling. In contrast, cryo-milling reduces the particle size of TWPs at the rate of -275.0 μm/d, which is nine times higher than that upon dry- and wet-milling. Dispersed cryo-milled TWPs had a hydrodiameter of 2.02 μm and were more stable in the aqueous phase in relation to the other aged TWPs. The results of this study suggest that cryo-milled TWPs can be used for aquatic exposure assessments as controls for real-world TWPs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemical Engineering, Kwangwoon University, Seoul, 01897, South Korea.
- Department of Applied Chemistry, Kyung Hee University, Yongin, 17104, South Korea.
- Risk Assessment Division, Environmental Health Research Department, National Institute of Environmental Research, Incheon, 22733, South Korea.
- Department of Chemical Engineering, Kwangwoon University, Seoul, 01897, South Korea. Electronic address: korea1@kw.ac.kr.
Förderung
- Korea Environmental Industry and Technology Institute
- National Institute of Environmental Research
Zitieren
APA
Shin, H., Jeong, S., Hong, J., Wi, E., Park, E., Yang, S. I., Kwon, J. T., Lee, H., Lee, J., & Kim, Y. (2023). Rapid generation of aged tire-wear particles using dry-, wet-, and cryo-milling for ecotoxicity testing. Environmental Pollution, 330, 121787. https://doi.org/10.1016/j.envpol.2023.121787
Vancouver
Shin H, Jeong S, Hong J, Wi E, Park E, Yang SI, et al. Rapid generation of aged tire-wear particles using dry-, wet-, and cryo-milling for ecotoxicity testing. Environmental Pollution. 2023;330:121787. doi:10.1016/j.envpol.2023.121787
BibTeX
@article{Shin2023,
author = {Shin, Hyeokjin and Jeong, Sohee and Hong, Jaehwan and Wi, Eunsoo and Park, Eunhae and Yang, Sung Ik and Kwon, Jung-Taek and Lee, Hyejin and Lee, Jaewoong and Kim, Younghun},
title = {Rapid generation of aged tire-wear particles using dry-, wet-, and cryo-milling for ecotoxicity testing},
journal = {Environmental Pollution},
year = {2023},
volume = {330},
pages = {121787},
doi = {10.1016/j.envpol.2023.121787}
}
EUVIMED