EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Portable HEPA air filtration effects on particulate matter, radioactivity, and chemical constituents in occupied homes

Choong-Min Kang, Joy Lawrence, Shaodan Huang, Jennifer Kang, Jun Young Yoo, Chan Jung Park, Mary B Rice, Wanda Phipatanakul, Eric Garshick, Petros Koutrakis

Environment International · 2026

DOI: 10.1016/j.envint.2026.110528 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Environment International, 2026. Verfasst von Choong-Min Kang und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Environmental Health, Harvard T.H. Chan School of Public Health, Boston, MA 02215, USA. Electronic address: cmkang@hsph.harvard.edu. Hauptthemen laut MEDLINE: Particulate Matter, Air Pollution, Indoor, Filtration, Air Filters. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIAID NIH HHS, NHLBI NIH HHS, NIEHS NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Although in-home air cleaners are known to reduce particulate matter (PM) concentrations, their effects on PM chemical constituents and particle-bound radioactivity (PR) under real-world residential conditions remain poorly characterized. We evaluated the effects of a portable high-efficiency particulate air (HEPA) cleaner on particle mass, chemical composition, and particle-bound radioactivity in occupied homes. We collected 86 indoor samples from 19 homes in the Boston metropolitan area between June 2017 and March 2018. Measurements included size-resolved PM fractions (PM2.5, PM10-2.5, and > PM10), short-lived α activity (SLA) and long-lived α activity (LLA) associated with PM2.5, elemental composition, black carbon (BC), and a biomass-burning/cooking surrogate (DC). HEPA operation substantially reduced indoor particle concentrations, with mean decreases of 3.7, 1.0, and 0.5 µg/m3 for PM2.5, PM10-2.5, and >PM10, corresponding to removal efficiencies of approximately 60, 37, and 32%, respectively. LLA decreased by 0.68 mBq/m3, corresponding to a 63% removal efficiency (p < 0.001). SLA also decreased substantially, by 31.4 Bq/m3, or approximately 70%; however, this reduction was not statistically significant, likely because of the limited number of valid SLA measurements. Major and trace PM2.5 constituents -including sulfur, crustal elements, BC, and DC-also decreased significantly during HEPA operation. By jointly assessing PM mass, chemical composition, and particle-bound radioactivity across seasons (summer versus winter) and residential locations (family rooms versus basements), this study extends previous chamber-based and limited field investigations of air-cleaner performance. Overall, the findings indicate that portable HEPA cleaners can reduce indoor PM, chemically diverse PM2.5 constituents, and particle-bound radon decay products in occupied homes. HEPA filtration may therefore provide a practical supplemental strategy for reducing combined exposures to PM and particle-bound radioactivity. However, it does not remove gaseous radon and should not replace radon source-control or remediation measures.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Particulate MatterAir Pollution, IndoorFiltrationAir FiltersAir PollutantsBostonEnvironmental MonitoringHousing

Stichwörter der Autor:innen

HEPA interventionIndoor particulate matterParticle radioactivityReduced health risks

Substanzen

Particulate MatterAir Pollutants

Autor:innen und Institutionen

  • Department of Environmental Health, Harvard T.H. Chan School of Public Health, Boston, MA 02215, USA. Electronic address: cmkang@hsph.harvard.edu.
  • Department of Environmental Health, Harvard T.H. Chan School of Public Health, Boston, MA 02215, USA.
  • Department of Occupational and Environmental Health Sciences, Peking University, China.
  • Research Division, Coway R&D Center, Seoul 08826, South Korea.
  • Clinical Research Center, Boston Children's Hospital Asthma, Allergy & Immunology, Dermatology & Rheumatology, Harvard Medical School, Boston, MA 02115, USA.
  • Pulmonary, Allergy, Sleep, and Critical Care Medicine Section, Medical Service, VA Boston Healthcare System; Harvard Medical School, Boston, MA 02130, USA.

Förderung

  • NIAID NIH HHS
  • NHLBI NIH HHS
  • NIEHS NIH HHS
  • United States Environmental Protection Agency

Zitieren

APA

Kang, C. M., Lawrence, J., Huang, S., Kang, J., Yoo, J. Y., Park, C. J., Rice, M. B., Phipatanakul, W., Garshick, E., & Koutrakis, P. (2026). Portable HEPA air filtration effects on particulate matter, radioactivity, and chemical constituents in occupied homes. Environment International. https://doi.org/10.1016/j.envint.2026.110528

Vancouver

Kang CM, Lawrence J, Huang S, Kang J, Yoo JY, Park CJ, et al. Portable HEPA air filtration effects on particulate matter, radioactivity, and chemical constituents in occupied homes. Environment International. 2026. doi:10.1016/j.envint.2026.110528

BibTeX
@article{Kang2026,
  author = {Kang, Choong-Min and Lawrence, Joy and Huang, Shaodan and Kang, Jennifer and Yoo, Jun Young and Park, Chan Jung and Rice, Mary B and Phipatanakul, Wanda and Garshick, Eric and Koutrakis, Petros},
  title = {Portable HEPA air filtration effects on particulate matter, radioactivity, and chemical constituents in occupied homes},
  journal = {Environment International},
  year = {2026},
  doi = {10.1016/j.envint.2026.110528}
}
Kostenlos starten →