Fachartikel in der Zeitschrift Environment International, 2024. Verfasst von Zukun Wang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Tianjin Key Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Tianjin, Chi…. Hauptthemen laut MEDLINE: Air Pollution, Indoor, Particulate Matter, Railroads, Sick Building Syndrome. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Metro systems play a crucial role in public transportation worldwide. Given that metro stations are unique built environments with a significant volume of daily commuters, ensuring a satisfactory air quality in these spaces becomes paramount. This study involved measurements of indoor air quality (IAQ), staff satisfaction, particulate matter (PM) chemical composition, and heavy metal health risks at a typical metro station in Tianjin over two seasons. Although the air exchange rate was sufficient to maintain a CO2 concentration less than 1000 ppm, the proportion of staff reporting no sick-building symptoms decreased from 83 % in spring to 25 % in winter. An average mass concentration of PM with an aerodynamic diameter smaller than 2.5 μm (PM2.5) of 68.0 ± 42.2 μg/m3 and an average PM1 mass concentration of 51.8 ± 33.3 μg/m3 were observed on the platform in winter. PM2.5 contained more metal in winter than in spring. PM2.5 in winter contained more metal in winter than in spring. With a lower relative humidity in winter, the coefficient of friction between railway wheels and rails increased, thus increasing particle emission. The carcinogenic risk of Cr on the platform was unacceptable. Moreover, the health risks induced by Ba should be investigated. The findings indicate that PM control at metro stationss, particularly on platforms in winter, should be emphasized.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Tianjin Key Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Tianjin, China.
- Tianjin Key Laboratory of Indoor Air Environmental Quality Control, School of Environmental Science and Engineering, Tianjin University, Tianjin, China. Electronic address: yaomy@tju.edu.cn.
Zitieren
APA
Wang, Z., Liu, J., Yao, M., He, M., Shang, W., & Dong, X. (2024). Indoor air quality and sick-building syndrome at a metro station in Tianjin, China. Environment International. https://doi.org/10.1016/j.envint.2024.108673
Vancouver
Wang Z, Liu J, Yao M, He M, Shang W, Dong X. Indoor air quality and sick-building syndrome at a metro station in Tianjin, China. Environment International. 2024. doi:10.1016/j.envint.2024.108673
BibTeX
@article{Wang2024,
author = {Wang, Zukun and Liu, Junjie and Yao, Mingyao and He, Mingtong and Shang, Wenzhe and Dong, Xinyue},
title = {Indoor air quality and sick-building syndrome at a metro station in Tianjin, China},
journal = {Environment International},
year = {2024},
doi = {10.1016/j.envint.2024.108673}
}
EUVIMED