EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Synergistic control potential of flue gas pollutants under Ultra-Low emission standards in waste incineration plants

Jicui Cui, Jiyang Li, Haoyu Zhang, Ruina Zhang, Wenchao Ma, Ying Zhu, Wenxiang Yuan, Michael Palocz-Andresen, Youcai Zhao, Ziyang Lou

Environment International · 2024-04 · 186 · 108590

DOI: 10.1016/j.envint.2024.108590 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Environment International, 2024-04. Verfasst von Jicui Cui und 9 weiteren Autor:innen. Beteiligte Einrichtung: Shanghai Engineering Research Center of Solid Waste Treatment and Resource, School of Environmental Science and Engineering, Shanghai Jiao Tong Unive…. Hauptthemen laut MEDLINE: Incineration, Air Pollutants, Environmental Monitoring. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

As the dominant waste disposal process, incineration is regarded as the main incentive for the "not-in-my-backyard" syndrome, and faces an inescapable pressures of ultra-low emissions (ULE). Establishing precise response relationships between emission factors (EFs) and full-process influencing factors can provide guidance for the synergistic mitigation of flue gas pollutants (FGPs). In this work, the multi-dimensional EFs of FGPs were identified by initially integrating FGPs concentration monitoring data of existing 1,226 processing lines in China, technologies applied and operational experience (OE), local economic and political characteristics. Significant regional imbalance performance was observed, which EFs in the coastal regions were 3.55-92.39 % lower than those of the inland areas. NOx, SO2, HCl were identified as critical components requiring further reduction under the ULE standards, with exceedance rates recorded at 73.07 %, 38.90 %, and 56.69 %, respectively. An indicative value of 20 mg/m3 for PM is recommended for the control of heavy metals of Cd + Tl and Sb + As + Pb + Cr + Co + Cu + Mn + Ni based on the correlation coefficients of r = 0.28 (p < 0.001) and r = 0.20 (p = 0.002), respectively. Waste composition and OE were quantified as the main contributors of EFs' disparities by the tree-branching controlled variable approach established in this study. Predictive models for FGPs control process and corresponding EFs were constructed. EFs of nine FGPs in 2030 would decrease by 0.97-65.42 %, due to more complex purification processes employed to meet ULE's limitations, such as the application of five-stage processes growing from 45.60 % to 58.28 %. While regional imbalance in EFs-SO2 and EFs-HCl were extended with increases from 25.83 % to 33.07 % and 9.91 % to 32.32 %, respectively, due to the consistent disparities of OE and growing heterogeneity of control policies. Enhancing interregional empirical exchanges, reducing the regional market monopolies, and formulating technical guidelines would be beneficial to synergize the reduction of FGPs emissions and alleviate regional imbalance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

IncinerationAir PollutantsEnvironmental MonitoringChinaAir PollutionMetals, HeavyGases

Stichwörter der Autor:innen

Emission factorsMunicipal solid waste incinerationOperation experienceRandom forest predictionRegional imbalanceSynergistic mitigation

Substanzen

Air PollutantsMetals, HeavyGases

Autor:innen und Institutionen

  • Shanghai Engineering Research Center of Solid Waste Treatment and Resource, School of Environmental Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
  • Shanghai Environmental Sanitation Engineering Design Institute Co., Ltd, Shanghai 200323, China.
  • School of Environmental Science and Engineering / Key Laboratory of Efficient Utilization of Low and Medium Grade Energy (MoE) / Tianjin Key Lab of Biomass-wastes Utilization, Tianjin University, Tianjin 300072, China;…
  • Qilu University of Technology (Shandong Academy of Sciences), Advanced Materials Institute, Shandong Engineering Research Centre of Municipal Sludge Disposal, Jinan 250014, China.
  • Shanghai Institute for Design & Research on Environmental Engineering, Shanghai 200232, China.
  • Shanghai Jiao Tong University Sichuan Research Institute, Chengdu 610000, China.

Zitieren

APA

Cui, J., Li, J., Zhang, H., Zhang, R., Ma, W., Zhu, Y., Yuan, W., Palocz-Andresen, M., Zhao, Y., & Lou, Z. (2024). Synergistic control potential of flue gas pollutants under Ultra-Low emission standards in waste incineration plants. Environment International, 186, 108590. https://doi.org/10.1016/j.envint.2024.108590

Vancouver

Cui J, Li J, Zhang H, Zhang R, Ma W, Zhu Y, et al. Synergistic control potential of flue gas pollutants under Ultra-Low emission standards in waste incineration plants. Environment International. 2024;186:108590. doi:10.1016/j.envint.2024.108590

BibTeX
@article{Cui2024,
  author = {Cui, Jicui and Li, Jiyang and Zhang, Haoyu and Zhang, Ruina and Ma, Wenchao and Zhu, Ying and Yuan, Wenxiang and Palocz-Andresen, Michael and Zhao, Youcai and Lou, Ziyang},
  title = {Synergistic control potential of flue gas pollutants under Ultra-Low emission standards in waste incineration plants},
  journal = {Environment International},
  year = {2024},
  volume = {186},
  pages = {108590},
  doi = {10.1016/j.envint.2024.108590}
}
Kostenlos starten →