Abstract (Originalsprache)

Window area constitutes a significant part of façades of heritage buildings in French cities. An effective way to improve window performance as well as preserve the appearance of heritage buildings is to retrofit old single-glazed windows into supply-air double windows by putting a secondary window inside of the existing window. For the window renovation, the U-value is an important indicator. To accurately identify the U-values (i.e., the (cid:1) (cid:2)(cid:3) value, (cid:1) (cid:4)(cid:5)(cid:2) value and (cid:1) (cid:6)(cid:7)(cid:5)(cid:5) value) of supply-air double windows, a new guarded hot box (GHB) method was firstly proposed with improving the GHB setup and the calibration/testing procedure. Based on the GHB experiments, thermal performances of different window configurations were identified and compared. The results showed that the U-value reductions were in the range of 59.2%-80.8% by renovating a single-glazed window into a supply-air double window. Moreover, the window U-value was compared to the center-of-glass U-value which is often used in building codes to simulate building energy consumptions. It was found that the deviations between the window U-value and the center-of-glass U-value were in the range of 21.6%-45.5% for different window configurations. The GHB experimental data were further

Förderung

  • Région Auvergne-Rhône-Alpes
  • China Scholarship Council

Zitieren

APA

Huang, Y., Mankibi, M. E., & Cantin, R. (2023). Thermal performance characterization of supply-air double windows: A new guarded hot box protocol and numerical modelization. Energy and Buildings, 287, 112993. https://doi.org/10.1016/j.enbuild.2023.112993

Vancouver

Huang Y, Mankibi ME, Cantin R. Thermal performance characterization of supply-air double windows: A new guarded hot box protocol and numerical modelization. Energy and Buildings. 2023;287:112993. doi:10.1016/j.enbuild.2023.112993

BibTeX
@article{Huang2023,
  author = {Huang, Yujian and Mankibi, Mohamed El and Cantin, Richard},
  title = {Thermal performance characterization of supply-air double windows: A new guarded hot box protocol and numerical modelization},
  journal = {Energy and Buildings},
  year = {2023},
  volume = {287},
  pages = {112993},
  doi = {10.1016/j.enbuild.2023.112993}
}
Kostenlos starten →