Accurate and rapid electrochemical detection of fentanyl in hydrophobic ionic liquid at subzero temperatures
Electrochimica Acta · 2026-01 · 547 · 147872
DOI: 10.1016/j.electacta.2025.147872 ↗Kurz gefasst
Fachartikel in der Zeitschrift Electrochimica Acta, 2026-01. Verfasst von E Burcar und 7 weiteren Autor:innen. Beteiligte Einrichtung: Oakland University, Chemistry Department, 800 West University Drive, Rochester, Michigan, 48309-4454, United States. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIDA NIH HHS, National Science Foundation, National Institute of Justice.
Abstract (Originalsprache)
Fentanyl's extreme potency and widespread presence in illicit drug mixtures demand the development of rapid, selective, and field-deployable sensing technologies. In this study, we present an electrochemical impedance-based sensor for fentanyl detection using a polyanilinearginine (PANI-Arg) modified stainless-steel electrode immersed in the ionic liquid 1-butyl-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide (BMPyrr-NTf2). The sensor exhibits nanomolar sensitivity, fast response times, and strong selectivity against common street drug adulterants and over-the-counter medications. Optimization studies revealed that a DC potential of +0.4 V maximizes phase angle shifts (Δφ) without compromising polymer stability. Kinetic analysis demonstrated pseudo-first-order adsorption, with ~90% of signal attained within 5 minutes. Temperature-dependent trials confirmed that Δφ increases with temperature, consistent with a dual thermokinetic model combining Arrhenius-based ion conduction and Langmuir adsorption isotherm behavior. Importantly, the use of BMPyrr-NTf2 enables stable sensor performance at subzero temperatures, a condition where aqueous systems fail due to freezing. This unique thermal stability makes the platform especially suitable for uncontrolled environments in forensic or field applications. Together, these findings validate the potential of PANI-Arg sensors in ILs as practical, portable tools for real-time fentanyl detection.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Oakland University, Chemistry Department, 800 West University Drive, Rochester, Michigan, 48309-4454, United States.
- University of the incarnate word, 4301 Broadway, San Antonio, Texas, 78209, United States.
- Auburn Univesity, Department of Chemical Engineering, 222 Foy Union Cir, Auburn, Alabama, 36849, United States.
Förderung
- NIDA NIH HHS
- National Science Foundation
- National Institute of Justice
- National Institutes of Health
Zitieren
APA
Burcar, E., Keta, A., Dougherty, M., Evans, B., DeMerle, A., Yang, J., Zhang, X., & Wang, Z. (2026). Accurate and rapid electrochemical detection of fentanyl in hydrophobic ionic liquid at subzero temperatures. Electrochimica Acta, 547, 147872. https://doi.org/10.1016/j.electacta.2025.147872
Vancouver
Burcar E, Keta A, Dougherty M, Evans B, DeMerle A, Yang J, et al. Accurate and rapid electrochemical detection of fentanyl in hydrophobic ionic liquid at subzero temperatures. Electrochimica Acta. 2026;547:147872. doi:10.1016/j.electacta.2025.147872
BibTeX
@article{Burcar2026,
author = {Burcar, E and Keta, A and Dougherty, M and Evans, B and DeMerle, A and Yang, J and Zhang, X and Wang, Z},
title = {Accurate and rapid electrochemical detection of fentanyl in hydrophobic ionic liquid at subzero temperatures},
journal = {Electrochimica Acta},
year = {2026},
volume = {547},
pages = {147872},
doi = {10.1016/j.electacta.2025.147872}
}