Metagenomic analysis of oral microbiome around zinc oxide nanoparticle-coated mini-implants: A split-mouth trial
Journal of the World Federation of Orthodontists · 2026-08 · 15 (4) · 299-309
DOI: 10.1016/j.ejwf.2026.03.003 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Journal of the World Federation of Orthodontists, 2026-08. Verfasst von Jerome Thomas und 2 weiteren Autor:innen. Beteiligte Einrichtung: Post Graduate Resident, Department of Orthodontics and Dentofacial Orthopedics, Sri Ramachandra Dental College & Hospital, Sri Ramachandra Institute …. Hauptthemen laut MEDLINE: Zinc Oxide, Dental Implants, Microbiota, Orthodontic Anchorage Procedures. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 52 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: This study aimed to evaluate the changes in the oral microbiome surrounding zinc oxide nanoparticle (NP)-coated orthodontic mini-implants using whole-genome metagenomic sequencing and to compare the microbial colonization and clinical stability with uncoated orthodontic mini-implants. METHODS: A randomized split-mouth trial was conducted on 12 orthodontic patients requiring bilateral skeletal anchorage in the maxillary arch. Each patient received one zinc oxide NP-coated mini-implant and one uncoated implant. The implants were coated using radiofrequency magnetron sputtering. Peri mini-implant crevicular fluid samples were collected at 1 week (T1), 4 weeks (T2), and 3 months (T3) postinsertion, and the pooled sample at each time point was subjected to whole-genome shotgun metagenomic sequencing. Taxonomic and functional profiles were analyzed using Kraken and MEGAN6, with diversity indices calculated via the VEGAN R package. Stability was assessed using a 4-point semiquantitative mobility scoring. RESULTS: Alpha diversity indices (Shannon and Chao1) showed no comparable differences between coated and uncoated mini-implants at any time point. Descriptive analysis of pooled metagenomic samples showed lower relative abundance or absence of peri‑implant pathogens, including Porphyromonas gingivalis, Tannerella forsythia, Treponema denticola, and Parvimonas micra, around coated implants. Functional gene analysis revealed reduced expression of bacterial motility, chemotaxis, and ribosomal pathways in the coated group. All mini-implants remained clinically successful during follow-up. Mobility scores were significantly lower at 1 month (P = 0.04), but not at 3 months (P = 0.102). CONCLUSIONS: Within the constraints of pooled metagenomic analysis, zinc oxide NP-coated mini-implants were associated with a lower relative abundance of selected peri‑implant pathogens and differences in functional pathway profiles compared with uncoated implants. Overall microbial diversity did not differ significantly between groups. Both implant types remained clinically stable, although coated implants showed reduced early mobility at 1 month. These findings should be interpreted as exploratory, and further validation through patient-level metagenomic studies is warranted.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Post Graduate Resident, Department of Orthodontics and Dentofacial Orthopedics, Sri Ramachandra Dental College & Hospital, Sri Ramachandra Institute of Higher Education and Research (DU), Chennai, India.
- Reader, Department of Orthodontics and Dentofacial Orthopedics, Sri Ramachandra Dental College & Hospital, Sri Ramachandra Institute of Higher Education and Research (DU), Chennai, India.
- Professor and Associate Dean (Research), Department of Orthodontics and Dentofacial Orthopedics, Sri Ramachandra Dental College & Hospital, Sri Ramachandra Institute of Higher Education and Research (DU), Chennai, India…
Zitieren
APA
Thomas, J., Ananthanarayanan, V., & Padmanabhan, S. (2026). Metagenomic analysis of oral microbiome around zinc oxide nanoparticle-coated mini-implants: A split-mouth trial. Journal of the World Federation of Orthodontists, 15(4), 299-309. https://doi.org/10.1016/j.ejwf.2026.03.003
Vancouver
Thomas J, Ananthanarayanan V, Padmanabhan S. Metagenomic analysis of oral microbiome around zinc oxide nanoparticle-coated mini-implants: A split-mouth trial. Journal of the World Federation of Orthodontists. 2026;15(4):299-309. doi:10.1016/j.ejwf.2026.03.003
BibTeX
@article{Thomas2026,
author = {Thomas, Jerome and Ananthanarayanan, Venkateswaran and Padmanabhan, Sridevi},
title = {Metagenomic analysis of oral microbiome around zinc oxide nanoparticle-coated mini-implants: A split-mouth trial},
journal = {Journal of the World Federation of Orthodontists},
year = {2026},
volume = {15},
number = {4},
pages = {299--309},
doi = {10.1016/j.ejwf.2026.03.003}
}
EUVIMED