EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

A Technique to Avoid Endograft Lumen Narrowing during Endovascular Aortic Arch Repair in Chronic Dissections

Michal Proczka, Mohammad Zagzoog, Stéphan Haulon

EJVES Vascular Forum · 2026 · 66 · 33-36

DOI: 10.1016/j.ejvsvf.2026.05.005 ↗

Kurz gefasst

Fachartikel in der Zeitschrift EJVES Vascular Forum, 2026. Verfasst von Michal Proczka und 2 weiteren Autor:innen. Beteiligte Einrichtung: Aortic Centre, Department of Vascular Surgery, Hôpital Marie Lannelongue, Groupe Hospitalier Paris Saint Joseph, Université Paris-Saclay, Paris, Fran…. Die Arbeit nennt 9 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The use of retrograde branches during endovascular aortic arch repair in chronic dissections has been associated with endograft lumen compression in the distal arch true lumen. This results in a functional pseudocoarctation, which carries a risk of cardiac failure. Technique: This exemplar case presents a patient treated with a three-branch arch endograft for an anastomotic false aneurysm and a residual chronic arch dissection extending to the supra-aortic trunks. To overcome device compression, a kissing angioplasty of the endograft and the left common carotid artery branch was performed after achieving wire access to the left subclavian artery. This manoeuvre successfully disrupted the distal arch lamella while securing the left common carotid artery bridging stent and maintaining access to the left subclavian artery.

Discussion

This technique is now routinely performed in all patients presenting with chronic aortic dissections. In the authors' limited recent experience with short-term follow up, no instances of cardiac failure secondary to endograft lumen narrowing have been observed since implementing this manoeuvre. It appears to be a feasible and effective method for overcoming endograft lumen compression and its associated complications.

Schlagwörter

Stichwörter der Autor:innen

Aortic dissectionBalloon angioplastyCardiac failureEndovascular aortic repair

Autor:innen und Institutionen

  • Aortic Centre, Department of Vascular Surgery, Hôpital Marie Lannelongue, Groupe Hospitalier Paris Saint Joseph, Université Paris-Saclay, Paris, France.
  • Department of General, Vascular, Endocrine and Transplant Surgery, Medical University of Warsaw, Warsaw, Poland.
  • Faculty of Medicine, Sorbonne University, Paris, France.

Zitieren

APA

Proczka, M., Zagzoog, M., & Haulon, S. (2026). A Technique to Avoid Endograft Lumen Narrowing during Endovascular Aortic Arch Repair in Chronic Dissections. EJVES Vascular Forum, 66, 33-36. https://doi.org/10.1016/j.ejvsvf.2026.05.005

Vancouver

Proczka M, Zagzoog M, Haulon S. A Technique to Avoid Endograft Lumen Narrowing during Endovascular Aortic Arch Repair in Chronic Dissections. EJVES Vascular Forum. 2026;66:33-36. doi:10.1016/j.ejvsvf.2026.05.005

BibTeX
@article{Proczka2026,
  author = {Proczka, Michal and Zagzoog, Mohammad and Haulon, Stéphan},
  title = {A Technique to Avoid Endograft Lumen Narrowing during Endovascular Aortic Arch Repair in Chronic Dissections},
  journal = {EJVES Vascular Forum},
  year = {2026},
  volume = {66},
  pages = {33--36},
  doi = {10.1016/j.ejvsvf.2026.05.005}
}
Kostenlos starten →