EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Clinical and Haemodynamic Evaluation of a Novel Physician Modified Inner Branch Iliac Branch Device for East Asians

Mingwei Wu, Li Zhang, Shichao Liang, Wei Guo, Jiang Xiong

EJVES Vascular Forum · 2026 · 65 · 92-99

DOI: 10.1016/j.ejvsvf.2026.01.005 ↗

Kurz gefasst

Fachartikel in der Zeitschrift EJVES Vascular Forum, 2026. Verfasst von Mingwei Wu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Vascular and Endovascular Surgery, Chinese PLA General Hospital, Beijing, China. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Beijing Science and Technology Planning Project, National Natural Science Foundation of China, Beijing Natural Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The anatomic suitability of the iliac branch device remains limited, particularly in East Asians, in whom the common iliac arteries (CIAs) are notably short. This study aimed to evaluate the safety and haemodynamic effects of the physician modified inner branch iliac branch device (PM-IIBD) via clinical outcomes and computational fluid dynamics (CFD) analysis.

Method

In this observational case series study, clinical safety was evaluated in ten patients treated with the PM-IIBD for internal iliac artery preservation. CFD analyses were performed before surgery and at 12 month follow up to compare haemodynamic changes in four CIA regions. CFD parameters included velocity, pressure, time averaged wall shear stress (TAWSS), relative residence time, oscillatory shear index (OSI), energy loss, and flow distribution ratios.

Results

Technical success was 100%, with no peri-operative or follow up adverse events. CFD revealed minimal changes in pressure and velocity after PM-IIBD implantation, with only a slight post-operative decrease in external iliac artery average velocity (0.51 ± 0.12 m/s vs. 0.45 ± 0.16 m/s, p = .039). High oscillatory shear index areas in the CIA region significantly decreased after surgery (0.22 ± 0.14 vs. 0.11 ± 0.07, p = .036). In the PM-IIBD region, both the average TAWSS (0.40 ± 0.45 vs. 0.72 ± 0.22, p = .015) and maximum TAWSS increased statistically significantly (4.47 ± 4.16 vs. 8.44 ± 6.52, p < .001). The PM-IIBD inner branch region showed an increase in high TAWSS areas (0.11 ± 0.39 vs. 0.20 ± 1.44, p = .002). Energy loss decreased significantly after surgery (3.82 ± 2.13 vs. 3.11 ± 1.76, p = .013), with no significant changes in the relative residence time and flow distribution ratio.

Conclusion

Preliminary clinical and CFD analyses have demonstrated the efficacy and haemodynamic stability of the PM-IIBD. By reducing spatial demands on the CIA, the PM-IIBD expands anatomic suitability, offering a feasible solution for internal iliac artery preservation in East Asians.

Schlagwörter

Stichwörter der Autor:innen

Abdominal aortic aneurysmCommon iliac artery aneurysmComputational fluid dynamicsEndovascular aortic repairIliac branch device

Autor:innen und Institutionen

  • Department of Vascular and Endovascular Surgery, Chinese PLA General Hospital, Beijing, China.
  • Department of Vascular and Endovascular Surgery, Dazhou Central Hospital, Dazhou, China.
  • School of Life Science, Beijing Institute of Technology, Beijing, China.

Förderung

  • Beijing Science and Technology Planning Project
  • National Natural Science Foundation of China
  • Beijing Natural Science Foundation
  • Natural Science Foundation of Beijing Municipality
  • Beijing Council of Science and Technology

Zitieren

APA

Wu, M., Zhang, L., Liang, S., Guo, W., & Xiong, J. (2026). Clinical and Haemodynamic Evaluation of a Novel Physician Modified Inner Branch Iliac Branch Device for East Asians. EJVES Vascular Forum, 65, 92-99. https://doi.org/10.1016/j.ejvsvf.2026.01.005

Vancouver

Wu M, Zhang L, Liang S, Guo W, Xiong J. Clinical and Haemodynamic Evaluation of a Novel Physician Modified Inner Branch Iliac Branch Device for East Asians. EJVES Vascular Forum. 2026;65:92-99. doi:10.1016/j.ejvsvf.2026.01.005

BibTeX
@article{Wu2026,
  author = {Wu, Mingwei and Zhang, Li and Liang, Shichao and Guo, Wei and Xiong, Jiang},
  title = {Clinical and Haemodynamic Evaluation of a Novel Physician Modified Inner Branch Iliac Branch Device for East Asians},
  journal = {EJVES Vascular Forum},
  year = {2026},
  volume = {65},
  pages = {92--99},
  doi = {10.1016/j.ejvsvf.2026.01.005}
}
Kostenlos starten →