Deep Learning Application of YOLOv8 for Aortic Dissection Screening Using Non-contrast Computed Tomography
European Journal of Vascular and Endovascular Surgery · 2026
DOI: 10.1016/j.ejvs.2025.08.054 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift European Journal of Vascular and Endovascular Surgery, 2026. Verfasst von Zheyu Tang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Interventional and Vascular Surgery, The Third Affiliated Hospital of Nanjing Medical University (Changzhou Second People's Hospital), …. Hauptthemen laut MEDLINE: Deep Learning, Aortic Dissection, Tomography, X-Ray Computed, Aortic Aneurysm. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
OBJECTIVE: Acute aortic dissection (AD) is a life threatening condition that poses considerable challenges for timely diagnosis. Non-contrast computed tomography (CT) is frequently used to diagnose AD in certain clinical settings, but its diagnostic accuracy can vary among radiologists. This study aimed to develop and validate an interpretable You only look once version 8 (YOLOv8) deep learning model based on non-contrast CT to detect AD. METHODS: This retrospective study included patients from five institutions, divided into training, internal validation, and external validation cohorts. The YOLOv8 deep learning model was trained on annotated non-contrast CT images. Its performance was evaluated using area under the curve (AUC), sensitivity, specificity, and inference time compared with findings from vascular interventional radiologists, general radiologists, and radiology residents. In addition, gradient weighted class activation mapping (Grad-CAM) saliency map analysis was performed. RESULTS: A total of 1 138 CT scans were assessed (569 with AD, 569 controls). The YOLOv8s submodel achieved an AUC of 0.964 (95% confidence interval [CI] 0.939 - 0.988) in the internal validation cohort and 0.970 (95% CI 0.946 - 0.990) in the external validation cohort. In the external validation cohort, the performance of the three groups of radiologists in detecting AD was inferior to that of the YOLOv8s model. The model's sensitivity (0.976) was slightly higher than that of vascular interventional specialists (0.965; p = .18), and its specificity (0.935) was superior to that of general radiologists (0.835; p < .001). The model's inference time was 3.47 seconds, statistically significantly shorter than the radiologists' mean interpretation time of 25.32 seconds (p < .001). Grad-CAM analysis confirmed that the model focused on anatomically and clinically relevant regions, supporting its interpretability. CONCLUSION: The YOLOv8s deep learning model reliably detected AD on non-contrast CT and outperformed radiologists, particularly in time efficiency and diagnostic accuracy. Its implementation could enhance AD screening in specific settings, support clinical decision making, and improve diagnostic quality.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Interventional and Vascular Surgery, The Third Affiliated Hospital of Nanjing Medical University (Changzhou Second People's Hospital), Changzhou, China.
- Department of Interventional Radiology, First People's Hospital of Changzhou (Affiliated Hospital of Soochow University), Changzhou, China.
- Department of Oncology and Vascular Intervention, Gaochun People's Hospital, Nanjing, China.
- Department of Interventional Radiology, Wujin Hospital, Jiangsu University, Changzhou, China.
- Department of Radiology, The Third Affiliated Hospital of Nanjing Medical University (Changzhou Second People's Hospital), Changzhou, China.
- Department of Interventional Radiology, Huaian Hospital of Huai'an City (Huaian Cancer Hospital), Huai'an, China.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Tang, Z., Huang, Y., Hu, S., Shen, T., Meng, M., Xue, T., & Jia, Z. (2026). Deep Learning Application of YOLOv8 for Aortic Dissection Screening Using Non-contrast Computed Tomography. European Journal of Vascular and Endovascular Surgery. https://doi.org/10.1016/j.ejvs.2025.08.054
Vancouver
Tang Z, Huang Y, Hu S, Shen T, Meng M, Xue T, et al. Deep Learning Application of YOLOv8 for Aortic Dissection Screening Using Non-contrast Computed Tomography. European Journal of Vascular and Endovascular Surgery. 2026. doi:10.1016/j.ejvs.2025.08.054
BibTeX
@article{Tang2026,
author = {Tang, Zheyu and Huang, Yuanquan and Hu, Shibing and Shen, Tao and Meng, Mingzhu and Xue, Tongqing and Jia, Zhongzhi},
title = {Deep Learning Application of YOLOv8 for Aortic Dissection Screening Using Non-contrast Computed Tomography},
journal = {European Journal of Vascular and Endovascular Surgery},
year = {2026},
doi = {10.1016/j.ejvs.2025.08.054}
}
EUVIMED