EUVIMEDEUVIMED entdecken
Multizentrische Studie

Editor's Choice – Feasibility and Safety of Using Carbon Dioxide Exclusively in Regular Endovascular Aortic Aneurysm Repair: Results of a Multicentre, Prospective, Zero Iodine Contrast Endovascular Aneurysm Repair Study

Emiliano Chisci, Emanuele Ferrero, Michele Antonello, Luca Mezzetto, Raffaele Pulli, Giacomo Isernia, Mauro Gargiulo, Giovanni Pratesi, Luca Bertoglio, Stefano Michelagnoli, Zero Iodine Contrast EVAR Collaborative Study Group

European Journal of Vascular and Endovascular Surgery · 2025

DOI: 10.1016/j.ejvs.2024.11.011 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift European Journal of Vascular and Endovascular Surgery, 2025. Verfasst von Emiliano Chisci und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Vascular and Endovascular Surgery Unit, Usl Toscana Centro, San Giovanni di Dio Hospital, Florence, Italy. Electronic address:…. Hauptthemen laut MEDLINE: Endovascular Procedures, Carbon Dioxide, Aortic Aneurysm, Abdominal, Contrast Media. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 37 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: Carbon dioxide (CO2) angiography has emerged as a viable alternative to regular iodinated contrast medium (ICM) for guiding endovascular aneurysm repair (EVAR) procedures. This study aimed to evaluate the feasibility and safety of a standardised EVAR procedure using only CO2 angiography. METHODS: A prospective, multicentre, national study enrolled consecutive patients between January 2023 and January 2024 with asymptomatic abdominal aortic aneurysms measuring ≥ 55 mm and for whom a standard endovascular graft (instructions for use) was anatomically feasible. The study involved the use of an automatic CO2 injector to standardise intra-operative imaging. A strategy comprising five standardised steps was devised to visualise a target vessel (TV) that could not be seen during the first CO2 angiogram. The five steps were: (A) place the introducer closer to the TV; (B) tilt the table by 5 - 10° in the direction opposite to the TV; (C) selectively cannulate the TV; (D) cannulate the contralateral gate (only for repositionable devices); CO2 angiography was repeated in steps 1 - 2; and (E) use ICM. RESULTS: Two hundred and ninety-three patients were enrolled (10 centres), with a median age of 78 (interquartile range [IQR] 72, 83) years; 256 (87.4%) were male. The overall procedure time, fluoroscopy time, and injected CO2 volume were 90 (IQR 65, 125) minutes, 15 (IQR 10, 22) minutes, and 600 (IQR 400, 800) mL, respectively. The 30 day mortality, complication, and re-intervention rates were 0.3% (n = 1), 6.8% (n = 20), and 2.4% (n = 7), respectively. CO2 related adverse events were rare (1%; n = 3) and minor. A zero iodine contrast EVAR procedure was feasible in 240 (patients 81.9%). The five standardised steps were used extensively: step A, 170 procedures (58.0%); step B, 109 procedures (37.2%); step C, 21 procedures (7.2%); step D, 14 procedures (4.8%); and step E, 53 procedures (18.1%), with a median volume of 20 (IQR 10, 35) mL. Significant predictors for ICM use were aneurysm diameter > 70 mm and a lowermost renal artery positioned between 3 and 9 o'clock. CONCLUSION: This study demonstrated that the standardised zero iodine contrast EVAR protocol reported here is both safe and feasible and is applicable in 82% of consecutive non-selected patients. Limitations primarily arose from anatomical factors, and adjunctive standardised manoeuvres can effectively address these challenges in most cases.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Endovascular ProceduresCarbon DioxideAortic Aneurysm, AbdominalContrast MediaBlood Vessel Prosthesis ImplantationRadiography, InterventionalHumansMaleFeasibility StudiesAgedFemaleProspective StudiesAged, 80 and overTreatment OutcomeIodineEndovascular Aneurysm Repair

Stichwörter der Autor:innen

CO(2) angiographyEVARMulticentreProspective

Substanzen

Carbon DioxideContrast MediaIodine

Autor:innen und Institutionen

  • Department of Surgery, Vascular and Endovascular Surgery Unit, Usl Toscana Centro, San Giovanni di Dio Hospital, Florence, Italy. Electronic address: e.chisci@gmail.com.
  • Vascular and Endovascular Surgery Unit, Mauriziano Umberto I Hospital, Turin, Italy.
  • Division of Vascular and Endovascular Surgery, Department of Cardiac, Thoracic Vascular Sciences and Public Health, School of Medicine, University of Padua, Padua, Italy.
  • Department of Vascular Surgery, University and Hospital Trust of Verona, University of Verona -School of Medicine, Verona, Italy.
  • Section of Vascular Surgery, Department of Excellence of Experimental and Clinical Medicine, University of Florence, Florence, Italy.
  • Unit of Vascular and Endovascular Surgery, Santa Maria della Misericordia Hospital, Perugia, Italy.

Zitieren

APA

Chisci, E., Ferrero, E., Antonello, M., Mezzetto, L., Pulli, R., Isernia, G., Gargiulo, M., Pratesi, G., Bertoglio, L., Michelagnoli, S., & Zero Iodine Contrast EVAR Collaborative Study Group (2025). Editor's Choice – Feasibility and Safety of Using Carbon Dioxide Exclusively in Regular Endovascular Aortic Aneurysm Repair: Results of a Multicentre, Prospective, Zero Iodine Contrast Endovascular Aneurysm Repair Study. European Journal of Vascular and Endovascular Surgery. https://doi.org/10.1016/j.ejvs.2024.11.011

Vancouver

Chisci E, Ferrero E, Antonello M, Mezzetto L, Pulli R, Isernia G, et al. Editor's Choice – Feasibility and Safety of Using Carbon Dioxide Exclusively in Regular Endovascular Aortic Aneurysm Repair: Results of a Multicentre, Prospective, Zero Iodine Contrast Endovascular Aneurysm Repair Study. European Journal of Vascular and Endovascular Surgery. 2025. doi:10.1016/j.ejvs.2024.11.011

BibTeX
@article{Chisci2025,
  author = {Chisci, Emiliano and Ferrero, Emanuele and Antonello, Michele and Mezzetto, Luca and Pulli, Raffaele and Isernia, Giacomo and Gargiulo, Mauro and Pratesi, Giovanni and Bertoglio, Luca and Michelagnoli, Stefano and Zero Iodine Contrast EVAR Collaborative Study Group, Zero Iodine Contrast EVAR Collaborative Study Group},
  title = {Editor's Choice – Feasibility and Safety of Using Carbon Dioxide Exclusively in Regular Endovascular Aortic Aneurysm Repair: Results of a Multicentre, Prospective, Zero Iodine Contrast Endovascular Aneurysm Repair Study},
  journal = {European Journal of Vascular and Endovascular Surgery},
  year = {2025},
  doi = {10.1016/j.ejvs.2024.11.011}
}
Kostenlos starten →