EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Machine Learning Based Prediction of Post-operative Infrarenal Endograft Apposition for Abdominal Aortic Aneurysms

Willemina A van Veldhuizen, Jean-Paul P M de Vries, Annemarij Tuinstra, Roy Zuidema, Frank F A IJpma, Jelmer M Wolterink, Richte C L Schuurmann, Virtual Stenting Study Group

European Journal of Vascular and Endovascular Surgery · 2024

DOI: 10.1016/j.ejvs.2024.07.003 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Vascular and Endovascular Surgery, 2024. Verfasst von Willemina A van Veldhuizen und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Division of Vascular Surgery, University Medical Centre Groningen, Groningen, The Netherlands. Electronic address: w.a.van.vel…. Hauptthemen laut MEDLINE: Aortic Aneurysm, Abdominal, Machine Learning, Endovascular Procedures, Computed Tomography Angiography. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: Challenging infrarenal aortic neck characteristics have been associated with an increased risk of type Ia endoleak after endovascular aneurysm repair (EVAR). Short apposition (< 10 mm circumferential shortest apposition length [SAL]) on the first post-operative computed tomography angiography (CTA) has been associated with type Ia endoleak. Therefore, this study aimed to develop a model to predict post-operative SAL in patients with an abdominal aortic aneurysm based on the pre-operative shape. METHODS: A statistical shape model was developed to obtain principal component scores. The dataset comprised patients treated by standard EVAR without complications (n = 93) enriched with patients with a late type Ia endoleak (n = 54). The infrarenal SAL was obtained from the first post-operative CTA and subsequently binarised (< 10 mm and ≥ 10 mm). The principal component scores that were statistically different between the SAL groups were used as input for five classification models, and evaluated by means of leave one out cross validation. Area under the receiver operating characteristic curves (AUC), accuracy, sensitivity, and specificity were determined for each classification model. RESULTS: Of the 147 patients, 24 patients had an infrarenal SAL < 10 mm and 123 patients had a SAL ≥ 10 mm. The gradient boosting model resulted in the highest AUC of 0.77. Using this model, 114 patients (77.6%) were correctly classified; sensitivity (< 10 mm apposition was correctly predicted) and specificity (≥ 10 mm apposition was correctly predicted) were 0.70 and 0.79 based on a threshold of 0.21, respectively. CONCLUSION: A model was developed to predict which patients undergoing EVAR will achieve sufficient graft apposition (≥ 10 mm) in the infrarenal aortic neck based on a statistical shape model of pre-operative CTA data. This model can help vascular specialists during the planning phase to accurately identify patients who are unlikely to achieve sufficient apposition after standard EVAR.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic Aneurysm, AbdominalMachine LearningEndovascular ProceduresComputed Tomography AngiographyBlood Vessel Prosthesis ImplantationEndoleakHumansMaleFemaleAgedAged, 80 and overRetrospective StudiesBlood Vessel ProsthesisTreatment OutcomePredictive Value of TestsRisk FactorsAorta, AbdominalAortography

Stichwörter der Autor:innen

Abdominal aortic aneurysmAppositionArtificial intelligenceEndovascular aneurysm repairSupervised machine learning

Autor:innen und Institutionen

  • Department of Surgery, Division of Vascular Surgery, University Medical Centre Groningen, Groningen, The Netherlands. Electronic address: w.a.van.veldhuizen@umcg.nl.
  • Department of Surgery, Division of Vascular Surgery, University Medical Centre Groningen, Groningen, The Netherlands.
  • Department of Surgery, Division of Trauma Surgery, University Medical Centre Groningen, Groningen, The Netherlands.
  • Department of Applied Mathematics, Technical Medical Centre, University of Twente, Enschede, The Netherlands.
  • Department of Surgery, Division of Vascular Surgery, University Medical Centre Groningen, Groningen, The Netherlands; Multimodality Medical Imaging Group, Technical Medical Centre, University of Twente, Enschede, The Ne…

Zitieren

APA

van Veldhuizen, W. A., de Vries, J. P. M., Tuinstra, A., Zuidema, R., IJpma, F. F. A., Wolterink, J. M., Schuurmann, R. C. L., & Virtual Stenting Study Group (2024). Machine Learning Based Prediction of Post-operative Infrarenal Endograft Apposition for Abdominal Aortic Aneurysms. European Journal of Vascular and Endovascular Surgery. https://doi.org/10.1016/j.ejvs.2024.07.003

Vancouver

van Veldhuizen WA, de Vries JPM, Tuinstra A, Zuidema R, IJpma FFA, Wolterink JM, et al. Machine Learning Based Prediction of Post-operative Infrarenal Endograft Apposition for Abdominal Aortic Aneurysms. European Journal of Vascular and Endovascular Surgery. 2024. doi:10.1016/j.ejvs.2024.07.003

BibTeX
@article{vanVeldhuizen2024,
  author = {van Veldhuizen, Willemina A and de Vries, Jean-Paul P M and Tuinstra, Annemarij and Zuidema, Roy and IJpma, Frank F A and Wolterink, Jelmer M and Schuurmann, Richte C L and Virtual Stenting Study Group, Virtual Stenting Study Group},
  title = {Machine Learning Based Prediction of Post-operative Infrarenal Endograft Apposition for Abdominal Aortic Aneurysms},
  journal = {European Journal of Vascular and Endovascular Surgery},
  year = {2024},
  doi = {10.1016/j.ejvs.2024.07.003}
}
Kostenlos starten →