EUVIMEDEUVIMED entdecken
Multizentrische StudieOpen Access · CC BY 4.0

Multicentre Experience with Novel Bidirectional Double Cuffed Inner Branches for Complex Endovascular Aortic Repair

Márton Berczeli, Tilo Kölbel, Nikolaos Tsilimparis, Angelos Karelis, Gustavo S Oderich, Giuseppe Panuccio, Fiona Rohlffs, Björn Sonesson, Nuno V Dias

European Journal of Vascular and Endovascular Surgery · 2024

DOI: 10.1016/j.ejvs.2024.04.040 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift European Journal of Vascular and Endovascular Surgery, 2024. Verfasst von Márton Berczeli und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Sciences Malmö, Lund University, Malmö, Sweden; Vascular Centre, Department of Thoracic Surgery and Vascular Diseases, Skåne U…. Hauptthemen laut MEDLINE: Blood Vessel Prosthesis, Endovascular Aneurysm Repair, Prosthesis Design. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: This study aimed to report the initial experience with a novel bidirectional double cuff inner branch design for incorporation of renal and mesenteric arteries in patients undergoing fenestrated and branched endovascular aortic repair (F/BEVAR). METHODS: A retrospective review was undertaken of the experience of F/BEVAR with grafts integrating at least one bidirectional double cuffed inner branch implanted at three tertiary aortic centres between March 2022 and June 2023. All consecutive patients were included. Baseline characteristics, operative data, and follow up data were collected. Results were presented as number or median (interquartile range) unless otherwise stated. RESULTS: Thirteen patients (10 male; median age 72 [68, 77] years) had F/BEVAR using a total of 15 bidirectional double cuffed inner branches (30 cuffs). Indications for bidirectional doubled cuffed inner branches included cranial vessel orientation or double renal arteries in four patients each, common coeliomesenteric trunk in three patients, and early renal artery bifurcation, renal artery origin from a false lumen requiring a flexible route for catheterisation, and surplus configuration in one patient each. Twenty three of the 30 cuffs were used, whereas the remaining seven cuffs were intentionally occluded with vascular plugs. Target vessel incorporation was successful in all bidirectional branches. There was one technical failure related to unsuccessful catheterisation of a left renal artery targeted through a unidirectional caudal inner branch. During a median follow up of seven months there were no instances of target vessel instability or re-interventions and two patients died of causes unrelated to the bidirectional branches. CONCLUSION: The results of the use of bidirectional double cuff inner branches are promising, with high technical success and no short term branch related complications in this preliminary experience. This could potentially expand the applicability of branch endografting of complex endovascular aortic repairs, but long term results are still missing.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood Vessel ProsthesisEndovascular Aneurysm RepairProsthesis DesignAgedFemaleHumansMaleAortic Aneurysm, AbdominalMesenteric ArteriesPostoperative ComplicationsRenal ArteryRetrospective StudiesStentsTreatment Outcome

Stichwörter der Autor:innen

Aortic aneurysmBEVARBidirectional branchBranched endovascular aortic repairComplex endovascular aortic repairInner branch

Autor:innen und Institutionen

  • Department of Clinical Sciences Malmö, Lund University, Malmö, Sweden; Vascular Centre, Department of Thoracic Surgery and Vascular Diseases, Skåne University Hospital, Malmö, Sweden; Department of Vascular and Endovasc…
  • German Aortic Centre, University Heart & Vascular Centre, University Medical Centre Eppendorf, Hamburg, Germany.
  • Department of Vascular Surgery, Ludwig Maximilians University Hospital, Munich, Germany.
  • Department of Clinical Sciences Malmö, Lund University, Malmö, Sweden; Vascular Centre, Department of Thoracic Surgery and Vascular Diseases, Skåne University Hospital, Malmö, Sweden.
  • Advanced Aortic Research Program, Division of Vascular and Endovascular Surgery, Department of Cardiothoracic & Vascular Surgery, McGovern Medical School, University of Texas Health Science Centre at Houston, Houston, T…

Zitieren

APA

Berczeli, M., Kölbel, T., Tsilimparis, N., Karelis, A., Oderich, G. S., Panuccio, G., Rohlffs, F., Sonesson, B., & Dias, N. V. (2024). Multicentre Experience with Novel Bidirectional Double Cuffed Inner Branches for Complex Endovascular Aortic Repair. European Journal of Vascular and Endovascular Surgery. https://doi.org/10.1016/j.ejvs.2024.04.040

Vancouver

Berczeli M, Kölbel T, Tsilimparis N, Karelis A, Oderich GS, Panuccio G, et al. Multicentre Experience with Novel Bidirectional Double Cuffed Inner Branches for Complex Endovascular Aortic Repair. European Journal of Vascular and Endovascular Surgery. 2024. doi:10.1016/j.ejvs.2024.04.040

BibTeX
@article{Berczeli2024,
  author = {Berczeli, Márton and Kölbel, Tilo and Tsilimparis, Nikolaos and Karelis, Angelos and Oderich, Gustavo S and Panuccio, Giuseppe and Rohlffs, Fiona and Sonesson, Björn and Dias, Nuno V},
  title = {Multicentre Experience with Novel Bidirectional Double Cuffed Inner Branches for Complex Endovascular Aortic Repair},
  journal = {European Journal of Vascular and Endovascular Surgery},
  year = {2024},
  doi = {10.1016/j.ejvs.2024.04.040}
}
Kostenlos starten →