EUVIMEDEUVIMED entdecken
Multizentrische Studie

Long Term Outcomes of the Gore Excluder Low Permeability Endoprosthesis for the Treatment of Infrarenal Aortic Aneurysms

Stefan P M Smorenburg, Jorg L de Bruin, Clark J Zeebregts, Michel M P J Reijnen, Hence J M Verhagen, Jan M M Heyligers

European Journal of Vascular and Endovascular Surgery · 2024

DOI: 10.1016/j.ejvs.2024.03.028 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift European Journal of Vascular and Endovascular Surgery, 2024. Verfasst von Stefan P M Smorenburg und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Amsterdam University Medical Centres location Vrije Universiteit, Amsterdam, the Netherlands. Hauptthemen laut MEDLINE: Aortic Aneurysm, Abdominal, Blood Vessel Prosthesis, Endovascular Procedures, Blood Vessel Prosthesis Implantation. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: This study evaluated the long term outcomes of endovascular aneurysm repair using the Gore Excluder Low Permeability (LP) endoprosthesis across high volume Dutch hospitals. METHODS: A retrospective analysis was conducted of patients treated with the Excluder LP for infrarenal abdominal aortic aneurysm (AAA) in four hospitals between 2004 and 2017. Primary outcomes were overall survival, freedom from re-interventions (overall, inside and outside instructions for use, IFU), and AAA sac dynamics: growth (> 5 mm), stabilisation, and regression (< 5 mm). Secondary outcomes were technical success (device deployment), procedural parameters, and re-interventions. Follow up visits were extracted from patient files, with imaging assessed for complications and AAA diameter. RESULTS: Five hundred and fourteen patients were enrolled, with a median (IQR) follow up of 5.0 (2.9, 6.9) years. Survival rates were 94.0% at one year, 73.0% at five years, and 37.0% at 10 years, with freedom from re-interventions of 89.0%, 79.0%, and 71.0%, respectively. 37.9% were treated outside IFU, leading to significantly more re-interventions over 10 years compared with those treated inside IFU (36.0% vs. 25.0%, respectively; p = .044). The aneurysm sac regressed by 53.5% at one year, 65.8% at five years, and 77.8% at 10 years, and grew by 9.8%, 14.3%, and 22.2%, respectively. Patients with one year sac growth had significantly worse survival (p = .047). Seven patients (1.4%) had a ruptured aneurysm during follow up. Over 15 years, type 1a endoleak occurred in 5.3%, type 1b in 3.1%, type 3 in 1.9%, type 4 in 0.2%, and type 2 in 35.6% of patients. CONCLUSION: This multicentre study of real world endovascular aneurysm repair data using the Gore Excluder LP endoprosthesis demonstrated robust long term survival and re-intervention rates, despite 37.9% of patients being treated outside IFU, with type 4 endoleak being rare. Treatment outside IFU significantly increased re-intervention rates and one year sac growth was associated with statistically significantly worse survival.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic Aneurysm, AbdominalBlood Vessel ProsthesisEndovascular ProceduresBlood Vessel Prosthesis ImplantationProsthesis DesignHumansMaleFemaleAgedRetrospective StudiesTreatment OutcomeAged, 80 and overNetherlandsTime FactorsPostoperative ComplicationsPermeabilityStentsRisk FactorsHospitals, High-VolumeReoperation

Stichwörter der Autor:innen

Abdominal aortic aneurysmEndoleakEndovascular aneurysm repairGore ExcluderLong term survivalLow permeability

Autor:innen und Institutionen

  • Department of Surgery, Amsterdam University Medical Centres location Vrije Universiteit, Amsterdam, the Netherlands.
  • Department of Vascular Surgery, Erasmus Medical Centre, Rotterdam, the Netherlands.
  • Department of Surgery (Division of Vascular Surgery), University Medical Centre Groningen, University of Groningen, Groningen, the Netherlands.
  • Department of Surgery, Rijnstate, Arnhem, the Netherlands; Multi-Modality Medical Imaging Group, University of Twente, Enschede, the Netherlands.
  • Department of Surgery, Elisabeth-Tweesteden Hospital, Tilburg, the Netherlands. Electronic address: j.heyligers@etz.nl.

Zitieren

APA

Smorenburg, S. P. M., de Bruin, J. L., Zeebregts, C. J., Reijnen, M. M. P. J., Verhagen, H. J. M., & Heyligers, J. M. M. (2024). Long Term Outcomes of the Gore Excluder Low Permeability Endoprosthesis for the Treatment of Infrarenal Aortic Aneurysms. European Journal of Vascular and Endovascular Surgery. https://doi.org/10.1016/j.ejvs.2024.03.028

Vancouver

Smorenburg SPM, de Bruin JL, Zeebregts CJ, Reijnen MMPJ, Verhagen HJM, Heyligers JMM. Long Term Outcomes of the Gore Excluder Low Permeability Endoprosthesis for the Treatment of Infrarenal Aortic Aneurysms. European Journal of Vascular and Endovascular Surgery. 2024. doi:10.1016/j.ejvs.2024.03.028

BibTeX
@article{Smorenburg2024,
  author = {Smorenburg, Stefan P M and de Bruin, Jorg L and Zeebregts, Clark J and Reijnen, Michel M P J and Verhagen, Hence J M and Heyligers, Jan M M},
  title = {Long Term Outcomes of the Gore Excluder Low Permeability Endoprosthesis for the Treatment of Infrarenal Aortic Aneurysms},
  journal = {European Journal of Vascular and Endovascular Surgery},
  year = {2024},
  doi = {10.1016/j.ejvs.2024.03.028}
}
Kostenlos starten →